SmartPM 2000 EMS Energy Management System. System Feature Redundant configuration: Assure data safety Standard Port: It can be used for integrate meter, PLC, UPS device Open: It can connect other system through OPC Web: Support local, web remote visiting

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'PILOT reserves the right to modify features without prior notice in view of continued improvement' - socrates-flavian


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

SmartPM 2000 EMS

Energy Management System

  • System Feature
  • Redundant configuration: Assure data safety
  • Standard Port: It can be used for integrate meter, PLC,

UPS device

  • Open: It can connect other system through OPC
  • Web: Support local, web remote visiting
  • Analysis report: Optimize energy efficient through data

collecting and analysis and generate report

Branch Circuit Power Meter

Major Function

  • System Monitor and Control
  • Display wire diagram, on line display all kind of parameters and status
  • Power Quality Analysis
  • Monitor harmonic, unbalance variant, find the potential power quality problem
  • Energy Consumption and Analysis
  • Statistic each way incoming energy consumption and demand and print daily, monthly, yearly report, trend chart
  • Alarm Information and Event Management
  • Record alarm information when data over limit, record device running status, power quality abnormal and inform operator
  • Data Statistic and Report
  • Provide customized data statistic, system can store data based on setting time and generate different report

Zhuhai Pilot Technology Co., Ltd.Add: No. 15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone,

Zhuhai, Guangdong, China

Post Code: 519085Tel: +86 756 3629687/ 3629673

Fax: +86 756 3629600/ 3629700

Email: overseamarket@pmac.com.cn

http://www.pmac.com.cn

Your Representative

PILOT reserves the right to modify features without prior notice in view of continued improvement

ZHUHAI PILOT TECHNOLOGY CO., LTD.

slide2

PMAC201 Branch Circuit Power Meter

PMAC201 Measurement Function

Management Solution

PMAC201 Branch Circuit Power Meter has completed function , easy to operate, reach to visual , accuracy management for power distribution of data center. Make sure data center running with safety and reliability.

  • 2 Incoming circuit monitoring

PMAC201 measures two incoming circuit electricity parameters include: I, U, P, PF, F, kWh, Demand,

Harmonic, Current unbalance

Stability

Reliability

Improving Energy Efficient

  • 63 Outgoing circuit monitoring

PMAC201 measures Max. 3 strips CT, Max. 63 outgoing circuit. Parameters include: I, P, PF, kWh,

Demand

  • Function
  • 2 incoming circuit and Max. 63 outgoing circuit electrical

parameter measuring and analysis

  • DI/DO status monitoring
  • Two lever alarm information for U, I abnormal
  • Power load analysis monitoring and pre-alarm
  • Standard 7” HMI display data and schematic wiring .

East to operate

  • Select strip 1, 2, or 3 CT based on outgoing circuit
  • Event Log: Record Max. 5000 event
  • PMAC201 support RS485 modbus communication port.

Advantage

  • Small size, one unit can monitor total 65 circuit
  • Saving cost , saving space
  • High reliability
  • Module design: CT module, display module, main module,

status module

  • It can monitor harmonic, demand, neutral current
  • CT measuring accuracy: Class 0.2
  • Two kind of alarm methods: Voice and LED
  • Max. record 5000 events
  • Memory: 128M

PMAC201 BCPM Schematic

PMAC201 BCPM Include

  • PMAC201 Main Module: Connect two incoming, and three group CT outgoing
  • PMAC201 CT Module: Integrating measure outgoing circuit, Max. 21 channels
  • PMAC201 Status Input Module: Integrating measure status input, Max. 21 channels each group
  • PMAC201 Display Module: 7 inch touch screen LCD, display each server RMS and setting all kinds of parameters
  • PMAC3216 Communication Unit: Used for data collection and upload
  • PMAC201 Main Module
  • Metal case design, High grade EMC capability
  • Integrating collecting incoming, outgoing circuit voltage, current,

status input

  • PMAC201 DI Module
  • No need additional contact, status be collected through

switch

  • Each status has input indictor light

Technical Specification

  • PMAC201 CT Module
  • Suitable to install in cabinet 600mm
  • CT accuracy class 0.2 to assure accuracy
  • 1 strip has 21 CTs
  • PMAC201 HMI
  • 7”LCD touch screen
  • Screen resolution 800*480
  • Display wire diagram