1 / 43

Temperature measurements during curing of inner layers at the 3 CMAs

Temperature measurements during curing of inner layers at the 3 CMAs. Carlos Lopez Paolo Fessia. Sensor distribution. Maximum and minimum temperature. Remarks on Ansaldo measurements. The oil has reached a max temperature of 242º C. This is about 12 º C higher than the normal value.

shiro
Download Presentation

Temperature measurements during curing of inner layers at the 3 CMAs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Temperature measurements during curing of inner layers at the 3 CMAs Carlos Lopez Paolo Fessia

  2. Sensor distribution

  3. Maximum and minimum temperature

  4. Remarks on Ansaldo measurements • The oil has reached a max temperature of 242º C. This is about 12 º C higher than the normal value. • It is possible to re-scale the temperature seen by the coil to a “normal” oil temperature thanks to the correlation between oil temperatures and max temperatures measured during the cycles

  5. Therefore…. We can consider that the max coil temperature for a max oil temperature of 230° C would be about 7.5 ° C less, it means a max temperature of 222 ° - 223 ° C

  6. From Ansaldo dummy • If we estimate the error between coil and sensor in the mould starting from the Ansaldo dummy and we apply such error to the Ansaldo’ s mould measurements during the tests we get: N.B. the error increase with temperature therefore we are probably underestimating it

  7. Left to right

  8. Cold and Hot spotsRespect to average

  9. Repeatability

  10. Differences between companies I

  11. Other data

  12. Other data

  13. Ansaldo pressure applicationinner layer I

  14. Ansaldo pressure applicationouter layer