1 / 20

Some thoughts on the infrastructure, when the plasma coupling is not weak.

Fusion and electron capture rates in dense plasmas; have the wheels come off theory ??? or. Some thoughts on the infrastructure, when the plasma coupling is not weak. Ray Sawyer UCSB.

shalin
Download Presentation

Some thoughts on the infrastructure, when the plasma coupling is not weak.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fusion and electron capture rates in dense plasmas; have the wheels come off theory ??? or Some thoughts on the infrastructure, when the plasma coupling is not weak. Ray Sawyer UCSB

  2. Example #1 : Nuclear fusion rates 12C + 12C 23Na + p with Q=2MeV at T=5x108 K, r= 5 x109 g c-3 e.g. in bursts from accreting neutron stars The effect of the plasma corrections, in the standard approach, is a factor of 107 (Gasques et al 2005) “Standard” begins with The rest of “standard” is how one computes K

  3. My problem is that: Is not really correct in the r , T domain of the example. So am I saying that there is a calculation that might give a factor of 107 in a quantity that we need?? but where we haveno idea whatever of how to do the calculation??

  4. My problem is that: is nowhere nearly correct, in the r , T domain of the example. So am I saying that there is a calculation that might give a factor of 107 in a quantity that we need?? but where we haveno idea whatever of how to do the calculation?? er….

  5. My problem is that: is nowhere nearly correct, in the r , T domain of the example. So am I saying that there is a calculation that might give a factor of 107 in a quantity that we need?? but where we haveno idea whatever of how to do the calculation?? It’s not quite that bad, maybe

  6. Q: How much uncertainty in fusion rates can we tolerate? ? • A: In many contexts quite a lot ; perhaps a factor of 10 ?? • Fusion rates go as such a high power of T that the multiplying coefficient usually doesn’t matter much. • But In any given range of energy, a big energy dependent factor can change the effective exponent.

  7. Example #2 : Electron capture Effects of plasma induced ionic energy shifts • In [7], a comprehensive calculation of the infall e-capture in type II SN, these energy shifts bring about a 25% rate reduction for • r=1010 g c-3 , T=.75 MeV • Factor of 2 reduction when • r=1012 g c-3 , T=1.5 MeV • I find this to be a spurious effect. Does this matter?

  8. Fusion • Two very different regimes: • Non-degenerate electrons . Weakly coupled plasma in solar core . • Salpeter (1951) calculated correlator, • K 1,2 (0) corrected for screening • ( effects of a few % ,for, e.g. , p+7Be 8B+g ) • All issues completely settled (in spite of a lot of theoretical noise.) • 2. Highly degenerate electrons . Strongly coupled plasma. • G = P.E./K.E > 1 • A lot of work has gone into calculating the classical correlator for this case. • Results: Probably semi-OK in some domains--come back to this. • But--

  9. Trouble ahead For the case in which Q (energy release) is not >> Gamow Energy* Then *Gamow energy is the energy at which the product of a penetration factor and a Boltzmann distribution function maximizes. In solar reactions it is of order 10 kBT for some reactions. In more extreme environments It can be orders of magnitude greater than kBT.

  10. We start over: Process: Nuc1+Nuc2 -> Nuc3+Nuc4 • where (for pedagogical reasons only) , #2 and #4 have infinite mass and are located at r=0 • Environment: N ions with coords. R1, R2 ……..RN • Electrons: so degenerate as to provide only a uniform neutralizing background. Rate: b=1/T RFS: Phys. Rev. Lett. 104, 191103 (2010) L. S. Brown and RFS: Rev. Mod. Phys. 69, 411 (1997) Here H contains KE and Coulomb interactions of all particles in the brew. The coupling g is for a point nuclear interaction describing the actual fusion— ---the equivalent of saying that the energy dependence of lab cross-section (times v) is entirely from Coulomb.

  11. Process: N1+N2 -> N3+N4 Environment: N ions with coords. R1, R2 ……..RN Electrons: so degenerate as to provide only a uniform neutralizing background. Rate: If we cross out this t and replace this H with H0 (no interaction between plasma and fusion products) Then we arrive back exactly at the standard theory And it appears to be OK when Q>>EGamow

  12. Digression—what exactly is the “standard” theory? Begin with (again) • Calculate the classical correlator K1,2 down to some small r • Define an effective potential Veff by • Veff(r) = T log [ Keff (r) ] • Calculate the tunneling to r=0 as though there existed only the two fusing nuclei • H. Dewitt and others call this the “basically classical” approach. Is it really • justified even if one accepts the ansatz ?? • There is pretty much only one paper in the literature that gives insight…..

  13. Militzer and Pollock 2005 (using techniques of Ceperely): where ns is maybe 100 and N =54 • Now each factor is effectively at a high temperature ns T. Then we • can make a lowest order perturbation expansion of the link. • But the integration manifold is huge— • 3 (N+2) ns dimensional • Finally—can compare with “basically classical”. Results • more or less agree in some regions—not in others

  14. Good news and bad news here: • Good news: somebody finally did a real calculation • Bad news: in a narrow corner of parameter space • ?? news:Proponents of “basically classical” claim these authors’ • results support their traditional approach. • (Though this wasn’t totally clear to the original authors or to me.) • Worse news: no one will go near that calculation again. • Terrible news: In any case, we are comparing calculations of the • wrong quantity • Not even news: • To try to make progress I attempt an expansion • in the parameter Q-1 .

  15. Note: in the correct expression As is, direct numerical computation is impossible because of oscillations. But In a perturbative approximation this has a factor t-1/2 Then in these factors we can distort the t integration contour to the two sides of the imaginary axis and have exponential decrease for increasing t. When we approximate final factor as <0, PL |e-iHt |0,PL’ > = d (PL –PL’) <0, PL |e-iHt |0,PL > Get corrections of order 50% in prototype 12C +12C case in which G=12

  16. Electron capture e- +A n +B Rate: GV2 or GA2 and nuclear M.E.2 here where And Ha is Hamiltonian for nucleus A plus plasma, including electron. Hb likewise for nucleus B

  17. Transform to interaction picture. • Turn the perturbation crank • Just to order Salpeter (e3) • Get Debye—of order e where f(E) is the Fermi distribution f(E)= ( 1+exp[ (-me+t) E ] )-1 • No correction to Q for energy shift in plasma DEA –DEB !! • (even though we can easily calculate such a difference to order Salpeter) • In the degenerate limit, f2(E) =f(E), so no correctionat all

  18. Resonance-enhanced nuclear fusion rates • --another case in which plasma induced ionic energy shifts are invoked; • in this case a “shift in the resonance energy” • Lamb and Fushiki (1987) –application to triple a in dense systems (not in red giants) • Cooper, Steiner, and Brown (2009)- application to superbursts , in the case • that there is a 1.5 MeV resonant state in 12C+12C fusion • I believe that the energy shift effect for the latter case as implemented in • Itoh et al (2003), or Cussons et al (2002) is incorrect • This can make orders of magnitude of difference !

  19. There are three appendices to this talk, which I will not show here, • but will be happy to show to anyone, any time. • 1. Derivation of the basic rate expression. • 2. Perturbative graphs, and where they enter, • a. in support of some of the assertions made earlier • b. in explanation of the literature claiming new plasma effects that • matter even in the weakly coupled plasma. • There is a close relation between the errors in concept and formalism found • in this literature and some of those that we have discussed above. • Itoh’s corrections to resonance-enhanced fusion, which I find make • difference of a factor that runs from 10-4 at one end of a region of interest • to 102 at the other. (all for 12C + 12 C fusion at density r10=.5, a region of • T in the vicinity of 5x108 , and assuming a resonance energy of 1.5 MeV.

  20. Conclusions • This is a difficult subject area. • Needs : • manpower (person-power ?) • fresh faces • encouragement • $ support Above all it needs a milieu in which problems can be studied without undue regard to immediate impact on this or that piece of recent or anticipated observational data.