1 / 17

Update on Pb-Pb spectra

HMPID weekly meeting. Update on Pb-Pb spectra. G. Volpe. CERN, 04/09/2013. Spctra in Pb-Pb collisions: fit exapmples. Spectra in Pb-Pb collisions: pions raw yields. Centrality bins : 0 – 5 % 5 – 10 % 10 – 20 % 20 – 30 % 30 – 40 % 40 – 50 %.

sef
Download Presentation

Update on Pb-Pb spectra

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HMPID weekly meeting Update on Pb-Pb spectra G. Volpe CERN, 04/09/2013

  2. Spctra in Pb-Pb collisions: fit exapmples

  3. Spectra in Pb-Pb collisions: pions raw yields Centrality bins: 0 – 5 % 5 – 10 % 10 – 20 % 20 – 30 % 30 – 40 % 40 – 50 %

  4. Spectra in Pb-Pb: kaons raw yields Centrality bins: 0 – 5 % 5 – 10 % 10 – 20 % 20 – 30 % 30 – 40 % 40 – 50 %

  5. Spectra in Pb-Pbcollsions: protons raw yields Centrality bins: 0 – 5 % 5 – 10 % 10 – 20 % 20 – 30 % 30 – 40 % 40 – 50 %

  6. Spectra in Pb-Pb collisions: tracking efficiency Tracking efficiency convoluted with the detector acceptance in the required rapidity range (MC prod. : LHC12a17a_fix)

  7. Spectra in Pb-Pb collisions: PID efficiency (0-5 % centr.)

  8. Spectra in Pb-Pb collisions: PID efficiency (5-10 % centr.)

  9. Spectra in Pb-Pb collisions: PID efficiency

  10. Spectra in Pb-Pb collisions: distance cut correction

  11. Spectra in Pb-Pb collisions: pions (0-10 % centr.) Corrected spectra PRELIMINARY

  12. Spectra in Pb-Pb collisions: kaons (0-10 % centr.) Corrected spectra PRELIMINARY

  13. Spectra in Pb-Pb collisions: protons (0-10 % centr.) Corrected spectra PRELIMINARY

  14. Conclusions • Pb-Pb corrected spectra have beeb evaluated in two most central centrality bins (0-5%, 5-10%). The same procedure will be applied for the semi central collisions asap. • Main corrections have been applied (tracking eff., PID eff., distance cut), feed down still missing. • PID efficiency has been extracted fromMonte Carlo. It is a very critical parameter, real data have to be also used (V0’s decays).

  15. Backup

  16. Primarytracksmultiplicity

  17. Pb-Pb analysis status: protons PID eff. from V0s PID efficiency for protons and anti-protons, extracted by means of V0s selection. Difference between the two charge is present. Protons Anti-protons From Francesco

More Related