1 / 4

NINJA TSK Profiling Floats: Recent Operation and Data Transmission

Explore the successful deployment of 7 profiling floats with oxygen/chlorophyll sensors funded by Japanese Fisheries Research Agency, including NINJA floats. These floats, deployed in 2008, provide detailed data up to 500db with a 5-day interval. Utilizing Wetlabs FLNTU sensors with TSK shutters, data compression enables efficient transmission via ARGOS. Despite a year in operation, 2 floats and their sensors remain functional. Discover the parameters recorded and restored data details. Get insights into the operation and capabilities of these innovative floats.

sarajones
Download Presentation

NINJA TSK Profiling Floats: Recent Operation and Data Transmission

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NINJA (TSK) float – recent operationToshio Suga (JAMSTEC / Tohoku Univ.) • 7 profiling floats with oxygen/chlorophyll sensors were funded by Japanese Fisheries Research Agency and deployed in March-May 2008. • 3 floats were NINJA floats. • 40-db parking depth following mixed layer • 500-db profiling with 5-day interval • Wetlabs FLNTU sensor with TSK shutter • Data compression enabling data transmission from >200 levels through ARGOS • 2 floats and their FLNTU sensors are still working properly almost after one year from deployment.

  2. Wetlabs FLNTU and TSK Shutter FLNTU FLNTU with shutter shutter Cf. OEM model of FLNTU for APEX float

  3. Transmitted data Data compressing Restored data P T diff_t S diff_s CHLA diff_chl NTU diff_ntu (dbar) (deg.C) (psu) (microg/l) (NTU) 4.2 15.517 5 34.523 -5 0.647 2 0.090 0 6.1 15.522 -1 34.518 2 0.671 -2 0.090 0 8.2 15.521 0 34.520 0 0.647 -2 0.090 -1 10.515.521 111111 34.520 111111 0.622 111111 0.083 111111 12.3 15.519 1 34.520 0 0.634 -2 0.090 0 14.3 15.520 1 34.520 0 0.610 0 0.090 0 16.3 15.521 2 34.520 0 0.610 0 0.090 2 18.1 15.523 2 34.520 0 0.610 1 0.102 -2 20.015.525 111111 34.520 111111 0.622 111111 0.090 111111 21.9 15.522 -3 34.520 -1 0.610 -2 0.090 -1 24.4 15.519 2 34.519 1 0.586 6 0.083 1 25.9 15.521 -4 34.520 -1 0.659 -1 0.090 -1 28.1 15.517 2 34.519 -2 0.647 -2 0.083 1 30.115.519 111111 34.517 111111 0.622 111111 0.090 111111 32.2 15.516 3 34.518 1 0.598 0 0.083 1 34.1 15.519 -7 34.519 -2 0.598 3 0.090 0 36.1 15.512 0 34.517 0 0.634 11 0.090 4 38.4 15.512 5 34.517 0 0.769 -11 0.115 -4 40.015.517 111111 34.517 111111 0.634 111111 0.090 111111 … …

  4. Back into the market

More Related