TFT Blitzfire

TFT Blitzfire. The Task Force Blitzfire is a personal portable monitor (PPM) capable of flows of 500+ GPM and is easily deployed by one firefighter. It is supplied by a single 2 ½” hose, can be pre-connected to the apparatus, and can be mounted on the exterior of the rig for rapid deployment.

samara
Download Presentation

TFT Blitzfire

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TFT Blitzfire

  2. The Task Force Blitzfire is a personal portable monitor (PPM) capable of flows of 500+ GPM and is easily deployed by one firefighter.

  3. It is supplied by a single 2 ½” hose, can be pre-connected to the apparatus, and can be mounted on the exterior of the rig for rapid deployment.

  4. The design of the inlet and the discharge neck creates a downward pressure that adds stability to the Blitzfire.

  5. It has a rear pivoting inlet that allows the hose to stay flat to the ground.

  6. The folding legs extend outward to provide lateral stability.

  7. The discharge can be adjusted for a low attack angle.

  8. It can be secured to the ground or another object by using the provided strap and base ring.

  9. The operating handle has a ratchet feature that allows for partial opening of the monitor. • Pull the handle lock outward and pull the handle towards you.

  10. It has a safety feature that shuts off the monitor when a sudden force (in excess of) 1G is introduced. • Hydraulic dampening in the handle prevents water hammer in the Blitzfire.

  11. Not for extending lines • Because of the automatic shut-off feature, you should NOT extend hose lines from the Blitzfire. • Any force greater than 1 G will automatically shut the Blitzfire down: • Laterally • From the top • Blunt force • Water hammer (from the pump side) Any of these will trip this feature.

  12. Discharge pressures with solid tip • 100 feet of 2 ½” 100 PSI = 400 GPM 125 PSI = 450 GPM 150 PSI = 500 GPM

  13. Solid tip (continued) • 200 feet of 2 ½” 150 PSI = 435 GPM 180 PSI = 470 GPM 210 PSI = 500 GPM

  14. Fog tip settings • The fog tip has two settings: • Low Pressure (55 PSI) • Standard (100 PSI) Can also be adjusted to straight stream, fog, or flush.

  15. Discharge pressures with fog tip • 100 Feet of 2 ½” • Standard tip setting 205 PSI = 500 GPM

  16. Fog tip (continued) • 100 feet of 2 ½” • Low pressure setting 180 PSI = 500 GPM