1 / 13

Status at Glasgow

Status at Glasgow. Pre-qualification. Last Thursday pre-qualified 2 modules M-O-040 and M-O-044 Time table to qualification Visual Inspection and conformation scans done on both This week bond and test 1 st qualification module 2nd module bond after 1 st module fully electrically

salene
Download Presentation

Status at Glasgow

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status at Glasgow

  2. Pre-qualification • Last Thursday pre-qualified • 2 modules M-O-040 and M-O-044 • Time table to qualification • Visual Inspection and conformation scans done on both • This week bond and test 1st qualification module • 2nd module bond after 1st module fully electrically • Perl scripts • running for data archiving • Cgi script for Web access to be edited

  3. M-O-40 • 19 band channels warm (35C) • 23 band channels cold (11C) • 23C • Average input noise: Link0 = 1387e, Link1 = 1353e, Module = 1370e; • Average gain, Link0 = 53.6 mV/fC, Link1 = 55.6 mV/fC, Module = 54.6 mV/fC; • Average threshold variation (for TrimRange 0), Link0 = 1.48 mV, Link1 = 1.71 mV • Noise Occupancy, Link0 = 1.08x 10-5, Link1 = 4.43x 10-6, Module = 7.63x 10-6 • Average front-end input noise from Noise Occupancy, Link0 = 1416e, Link1 = 1369e, Module = 1393;

  4. M-O-44 • 35C 19 bad channels • 14C 23 bad channels • Average threshold variation (for TrimRange -1), Link0 = 1.68 mV, Link1 = 1.36 mV, Module= 1.52 mV • Average front-end input noise, from 10pt ResponseCurve without fan-in problem channels, Link0 = 1393e, Link1 = 1421e, Module = 1407e; • Average gain, from 10pt ResponseCurve without fan-in problem channels, Link0 = 54.4 mV/fC, Link1 = 54.7 mV/fC, Module = 54.5mV/fC; • Noise Occupancy,Link0 = 9.59x10-6, Link1 =1.95x10-5, Module = 1.45x10-5 • Average front-end input noise from Noise Occupancy,Link0 =1413e, Link1 =1444e ,Module =1428e • Average Timewalk,Link0 =6ns, Link1 =6ns ,Module =6ns

  5. NO M-O-040 - cold

  6. NO M-O-40 warm

  7. NO M-O-44 cold

  8. IV M-O-044 24C

  9. M-O-044

  10. M-O-044

More Related