An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Modeling Multifamily Heating Energy Use Can SEEM be used, or do we need to use a multi-zone model? Regional Technical Forum January 17, 2011

  2. Background • MF Weatherization UES is “out-of-compliance” due to lack of model calibration • In the RTF’s “Multifamily Weatherization UES Scoping Study (Phase 1),” SBW identified 5 studies that would provide useful data for calibration • See link to memo on MF Weatherization UES measure page • In “Phase 2,” the RTF will hire a contractor to use those 5 studies to perform a calibration exercise. • The SOW should specify the preferred model. • RTF-staff preference = SEEM • At the December 2011 RTF meeting, there was concern regarding using SEEM for multifamily buildings

  3. Background (2) • Definition: Multifamily • More than 4 units; and • 3 floors or less above grade • Prototypes • Townhouse on Crawlspace • 12 units • 3 stories • 1500 ft2 per unit • Townhouse on Slab (same specs) • Apartment Building (Double-loaded corridor) • 24 units • 3 stories • 1000 ft2 per unit • Measures • Insulation (Attic, Floor, Walls) • Windows

  4. Use SEEM or not? • Benefits of using SEEM • Consistent with other RTF work • Simple • Easily documentable • Negatives of using SEEM • Doesn’t allow for multi-zone modeling

  5. Discussion • What would we expect to get from multi-zone modeling that single-zone modeling wouldn’t provide? • Will ability to model individual apartments allow better savings estimates? • Common area heating setpoint & infiltration rates • Vary heating setpoint across units to account for different behavior (including vacancies) • What data would we need for model inputs?

  6. What’s Needed from RTF… • Clear direction regarding modeling software to use for the Multifamily Weatherization UES measures and attempted calibration exercise.