Update on bunch effect in LER and HER

Update on bunch effect in LER and HER. Systematic search for jumps in pressure, BLM and temperature steps occuring in perfect sync with the bunch pattern change on Oct 30, 9h20 LER all pumps and temp sensors surveyed HER SR pumps and bellows sensors All BLMs. List of temperature changes

Download Presentation

Update on bunch effect in LER and HER

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Update on bunch effect in LER and HER • Systematic search for jumps in pressure, BLM and temperature steps occuring in perfect sync with the bunch pattern change on Oct 30, 9h20 • LER all pumps and temp sensors surveyed • HER SR pumps and bellows sensors • All BLMs Guy Wormser , LAL Orsay

  2. List of temperature changes A/ Near IR IR2-A1 7037 +2 7030 +2 7037-2 +2 703952 -2 IR2-A2 7042-1 and -2 +2 T-Q5LV7 -5 T-q5lv3 -10 t-q4lv3 -8 tq4-lv7 -1 HER A TQ2lv10 -2 Tq2lv9 -1 tq2lv8 +1 tq1lv-1 +1 HER-B T-8028 LER-B T-q2Rv3 -2.5 LER Misc 3044AIR +2 LER Kick Part 1 T3040ki4 +5 T3018k53 -10 T3018Ki43 -10 Part 2 T3018K40 -8 T3018K39,38,37,36,35,32,32 -5 T3018K30 -10 T3018p02 -50 ! Ler Misc T3044 BL2 +20 LER Arcs Pr2 4122BLW,4112,4102,4092,4082,4072 -2 2022 -3 1092,1042,1032,1022,1012 -1 pr04 2022 -10 1092 -3 pr8 1112,1132,1142,1082 -1 1042 +1 pr10 4042-1 3072 +1 4102 -1 2122 -5 2032 +1 pr12 T3052blw -4 LER Quads pr2 4122qua -4 4112 -2 4102 -3 4092 -1 4072 +1 pr4 4072,4122,4132 +1 3102,3072 +1 pr6 4122,4112,4102,4092, 4132 +1 4102 -2 pr10 4132,4142,4152 -2 pr12 4902 +1 IR and LER Temp Results Guy Wormser , LAL Orsay

  3. Raw findings • Several temperators sensors are clearly affected while most are not. Some pumps readings are probably a reflexion of the temp changes (as Artem suggested )although I have not checked the physical coorelations.The list is given below for all steps greater than 1 deg F. • Although a 1 def F variation may seem small , I have checked that these variations constitute the most significant step in the last month or two months, ie the step on Oct 30, 9h18 is very visible on that time scale. Besides Her bellows (see furthre), the largest temperature changes are: • NearIR Q5LV3 -10 , Q4LV3 -8 • in the LER kicker T3018K53 -10 , T3040P01 +20, T3018P02 -50 , T3044bl2 +20 • The LER arc pumps do not exhibit a pressure change except two :VP4010 in PR10 and PR6 +30% change in each cases • Some HER straight pumps exhibit a 15% pressure change • The list of collimators that see the changes: • HER coll. • PR04: BLSC8035, 8062,9012 • PR12: 8072(*),9012,9062 (* this is the one I showed yesterday located in pr12 not PR02) • LER coll. • PR12: 4062,3092,3042 • PR4 :3074,3054,3040 • Finally, one must not forget that the sensors not indicated in the list below were looked at and do not see any change, which is also a piece of information. Guy Wormser , LAL Orsay

  4. Some examples of steps in BLM and temerature sensors Q2rv3 -2.5 deg LER-Pr4-bllc3074 Q5LV3 -10 deg T3018P02 -50deg Guy Wormser , LAL Orsay

  5. Pressure vs current before and after the pattern change in PR02 VP2074 Before After Guy Wormser , LAL Orsay

  6. Superimposed plots (2 weeks of data 20/10-4/11)PR02-VP2074 By-3 Multipacting supression in the by-2 pattern Bye-2 Guy Wormser , LAL Orsay

  7. Similar behaviour in other pumps exhibiting a pressuredownwards step at the transition SR2-3181 SR2 VP2053 Guy Wormser , LAL Orsay

  8. Another example in SR4 By 3 By 2 Guy Wormser , LAL Orsay

  9. Upward step in SR02VP3054 By 2 By 3 Guy Wormser , LAL Orsay

  10. Other upwards going pump SR4 VP3091 Guy Wormser , LAL Orsay

  11. A pump with no apparent step SR4 VP2091 Guy Wormser , LAL Orsay Bunch pattern change

  12. Before and after for VP2091 Before After (beware vertical scale differs) Guy Wormser , LAL Orsay

  13. First observations of temperaturevariations in the HER (looking at bellows) Two types of effects seen up to now: strong upward move such as this one PR02 T9092BLW +40 Deg! Pattern change Guy Wormser , LAL Orsay

  14. Or a step downwards reverting a 25 Oct upwards step PR10 9062BLW ? PR026082,9032,9102,6052,6082, 9042,... PR10 6042, 9042,9082 By2 pattern change Guy Wormser , LAL Orsay

  15. The temperature rise is due to resonance PR2-9092 +40 Guy Wormser , LAL Orsay

  16. Some other cases A future problem PR2-6042 Pr6-9022 +5 deg +40 deg Pr4-9132 +4 deg Guy Wormser , LAL Orsay

  17. But not all are resonances PR4-8042 +10 deg step As function of HER current Guy Wormser , LAL Orsay

  18. Conclusion • Bunch pattern effects in the LER: Multipacting variation • Definite evidence for multipacting reduction in the LER straight sections in all pumps showing a downward pressure step following the bunch pattern change of Oct 30, 9h18 • Mere translation for Pressure vs Current curves for pumps showing an upwards transistion (temperature effect?) • Mixture of these effects in the othr pumps to be investigated • No pressure change observed in the LER arcs except on PR6 and PR10 VP4010 (+30% effect) • Bunch pattern effects in the HER: most dramatic effect seen up to now is temperature change on bellows. Two categories • Temperature rise, from a few deg to +40 deg (PR2-9092, PR2-6042 but also PR10 6042 (10 deg) , Pr10 9132 (10 deg) • In almost all cases, obvious resonance behaviour at the bellow • Except PR4-8042 +10 deg jump without resonance • Jump downward of a few deg (5 typical), compensating a similar jump upwards which occurred on Oct 25 Guy Wormser , LAL Orsay