1 / 24

Preferred Utilities Manufacturing Corp.

rudolpho
Download Presentation

Preferred Utilities Manufacturing Corp.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    1. Preferred Utilities Manufacturing Corp.

    2. Tank Gauge D3 Tank Gauge Single Tank Applications Wire Float Available for Limited Tank Clearance Standard 4-20 mA output

    3. D5 Tank Gauge

    4. Wire Float Level Sensor

    5. Wire Float Level Sensor Requires only 14 Inches of Head Room Reads tanks 36 to 145 inches Tall Buna-N Float Requires only a 4 inch 125# Flange Easy to Install and Calibrate Can Be Installed in an Empty or Full Tank Can be mechanically tested in place Intrinsically Safe

    6. Versatility Solves Site Problems

    7. I plan to spend about 5 minutes showing them how they load the software, 10 minutes going over how the software is used. I plan to go through all the blanks to tell them what needs to go where and what fields are more important than others. I will show them the printing features here also. The heart of the program will be to go through 4 examples at 10 minutes each. With each example if will first give them the information a typical engineer might give them over the phone and then work up a example for each. These for examples will show each of the four systems shown at the beginning of the sizing program. The last 5 minutes will be spent talking about how they, the salespeople, can use this. I will talk about how they can give this to a “special engineer” at no cost instead of the typical $150 price. Secondly they can use the program to pull people in for a seminar or lunch and learn. Also they can follow up a seminar buy calling people to say they have a few left over and the salesperson can stop in to drop it off. I will also highlight the other items on the CD. With this slide the program will continue by using the PC to show the actual program. Hand outs will include these 3 slides along with the 4 printouts (reports) from the example applications. I plan to spend about 5 minutes showing them how they load the software, 10 minutes going over how the software is used. I plan to go through all the blanks to tell them what needs to go where and what fields are more important than others. I will show them the printing features here also. The heart of the program will be to go through 4 examples at 10 minutes each. With each example if will first give them the information a typical engineer might give them over the phone and then work up a example for each. These for examples will show each of the four systems shown at the beginning of the sizing program. The last 5 minutes will be spent talking about how they, the salespeople, can use this. I will talk about how they can give this to a “special engineer” at no cost instead of the typical $150 price. Secondly they can use the program to pull people in for a seminar or lunch and learn. Also they can follow up a seminar buy calling people to say they have a few left over and the salesperson can stop in to drop it off. I will also highlight the other items on the CD. With this slide the program will continue by using the PC to show the actual program. Hand outs will include these 3 slides along with the 4 printouts (reports) from the example applications.

    8. Tank Gauge Installation

    9. Underground Storage Tank (UST) Pipe leak detection requirements, pitch double wall pipe containment to the piping sump on the tank Typical pipe pitch is 1/8”/ft, long linear runs could present problems, might require a second sump All tanks Discriminating leak detector for the Dry Interstitial space of the tank Small cost to add on a new installation, major liability mitigationSmall cost to add on a new installation, major liability mitigation

    10. Fuel Leak Detection

    11. Leak Sensor Test Module

    12. HD-A1 Leak Detector Factory Mutual Approved Intrinsically Safe Monitors for both Oil and Water Three Detectors per Tank Gauge Manual Testing of Unit Completely Potted for Long Life Fail Safe Circuitry

    13. Level 3 Day Tank

    14. Leak Sensor

    16. Floor Leak Detector

    17. 2nd Manhole with Tank Access & Leak Detectors Max flow / max viscosity for calculations use our program use 100 mesh for e-gen sets.Max flow / max viscosity for calculations use our program use 100 mesh for e-gen sets.

    18. Leak Sensor Close-up Use solid line in our applications use our program - it will give you a nice print out. Use solid line in our applications use our program - it will give you a nice print out.

    19. Leak Detector

    20. Leak Sensor Test Modules

    21. Double Wall Containment Piping

    22. Day Tank Vent Detector

    23. Pump Set Leak Detector

    24. Single Source Fuel Handling

    25. Preferred Utilities Manufacturing Corp