1 / 17

Chapter 1.2

Chapter 1.2. Measurements and Uncertainties. 1.2.1 SI Units. 7 fundamental SI units m length kg mass s second A electric current K Temperature Cd intensity of light. 1.2.2 Derived SI Units. Derived SI Units- combinations of the fundamental SI units

rod
Download Presentation

Chapter 1.2

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 1.2 Measurements and Uncertainties

  2. 1.2.1 SI Units • 7 fundamental SI units • m length • kg mass • s second • A electric current • K Temperature • Cd intensity of light

  3. 1.2.2 Derived SI Units • Derived SI Units- combinations of the fundamental SI units • N, J, W, Pa, Hz, C, V, T, Wb, Bq • Example 1:

  4. 1.2.3 Convert units to SI • Examples 2 (conversion):

  5. 1.2.4 Know Common SI Prefixes • Question 3: • Accepted SI units: ms-2 not m/s2 • 1.2.5 Values must be stated in scientific notation • Example: 5.0 x 10-16 nm with appropriate prefixes

  6. 1.2.6 Uncertainty and error in measurement • Random errors= if readings of a measurement are above and below the true value with equal probability then errors are random. • Examples: changes in experimental conditions, such as temperature, pressure, humidity • Different person reading instrument • Malfunction of the apparatus

  7. Systematic error= due to the system or apparatus being used. • Examples: observer consistently making the same mistakes -apparatus calibrated incorrectly • Random errors can be reduced by repeating measurement many times and taking the average but not systematic errors.

  8. 1.2.7 • Precise= getting same answer over and over • Accurate= getting equally close to the answer you want. • Example: Dart Board 4 Graph Possibilities • A measurement may have great precision yet may be inaccurate.

  9. 1.2.8 • Measurements are accurate if systematic error is small. They are precise if random error is small. • Random errors can be reduced by taking many readings (measurements) and taking the average.

  10. 1.2.9 Significant Figures • Give measurements with numbers that can be guaranteed (measurement of a paper) • Should reflect precision of the value or input data to a calculation • Multiplication and division number of significant figures in a result should not exceed the least precise value upon which it depends.

  11. Example: assume reading error is half smallest division on instrument on a ruler. Interval is 1mm; half is .5mm • Measurement would be 14.54 +/- .05cm

  12. Uncertainties in calculated results 1.2.10 • Absolute uncertainty= error in measured time to show uncertainty. Drop a ball= uncertainty due to reaction time. • Example: Measured time= 1.0s, uncertainty= +/- .1 s • Uncertainty can also be shown as a fraction or a percentage. • +/- .1s or 1/10 or 10%

  13. 1.2.11 Determine Uncertainties in Results • Example pg. 34 Tsokos • To determine maximum uncertainties: • addition/subtraction= absolute uncertainties may be added • Mult/division/exponential= percentage uncertainties may be added • Trig fxns/other fxns= mean of highest/lowest possible answers may be calculated to determine uncertainty.

  14. 1.2.11 Determine Uncertainties in results • Can throw out outliers • Square root= percentage uncertainty is halved • Uncertainties in graphs - Excel example of how to calculate and draw error bars on graphs

  15. 1.2.12 • Uncertainty values must always be shown at the top of data tables as +/- sensible values • Represented as error bars on graph (only need to be considered when uncertainty in one or both plotted quantities is significant) • Do not have to have error bars for trig or log fxns. • Question 4: How to draw minimum and maximum gradients

  16. Excel Example with Error Bars • Best fit line must pass through error bars. If it doesn’t, point must be labeled as an outlier. • To determine uncertainty in gradient and intercept of straight line graph, error bars only need to be added to the first and last data points.

  17. Significant Figures Handout • Review significant figures and do several examples

More Related