1 / 21

Radha Korupolu, MBBS, MS (pgy2) Physical Medicine & Rehabilitation University of Kentucky

Spinal transcutaneous direct current stimulation to enhance locomotor training after spinal cord injury. Radha Korupolu, MBBS, MS (pgy2) Physical Medicine & Rehabilitation University of Kentucky. Mentor : Lumy Sawaki , MD, PhD Collaborator : Kenneth Chelette , MS

regis
Download Presentation

Radha Korupolu, MBBS, MS (pgy2) Physical Medicine & Rehabilitation University of Kentucky

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Spinal transcutaneous direct current stimulation to enhance locomotor training after spinal cord injury Radha Korupolu, MBBS, MS (pgy2) Physical Medicine & Rehabilitation University of Kentucky • Mentor: LumySawaki, MD, PhD • Collaborator: Kenneth Chelette, MS • University of Kentucky & Cardinal Hill Rehabilitation Hospital

  2. Background • Transcranial direct current stimulation • Modulates cortical excitability • Anodal stimulation increases neuronal firing rate • Cathode stimulation decreases neuronal firing rate • Effects may last for >1 hr after stimulation • Inexpensive • Non-invasive Nitsche et al., 2008; Nitsche et al., 2003; Priori, 2003

  3. Transcranialdirect current stimulation (tDCS) • Possible Mechanism: • Changes the resting membrane potential of the neurons in cortex • Adjuvant treatment options for pts suffering from • Stroke • Chronic pain • Depression • Cognitive deficits Hummel et al., 2005;Fregni et al., 2006a,b

  4. Transcutaneous spinal direct current stimulation (tsDCS) Preliminary studies in healthy subjects Suggest possibility of similar modulation in spinal neurons

  5. F. Cogiamanian et al. (2008) • Sample size : • 12 healthy subjects • Intervention: • tsDCS over T10 spinous process • 2.5 mA for 15 mins • anodal or cathodal • Outcome Measures: • Post. TibialN & Median N SEPs were recorded • Before, at current offset & 20 min after tcDCS (anodal/ cathodalDC)

  6. F. Cogiamanian et al. (2008) • Results • Anodal tcDCS decreased PTN SEPs amp by 25% • Effect lasted atleast 20 min • Serum neuronespecific enolase (NSE), a marker of neuronal damage • NSE level before & 1 h after stimulation measured in 5 subjects was not elevated after tsDCS

  7. T. Winkler et al. (2010) • Sample size : • 10 healthy subjects • Intervention: • tcDCS at T11 level 2 cm paravertebrally • 2.5 mA applied for 15 min • Cathodal, anodal or sham • Each subject received all modes of stim 1 week apart

  8. T. Winkler et al. (2010) • Outcome measures: • H-reflex • Before, at current offset, & 15 min after anodal, cathodal or sham tsDCS. • Results • Anodal tsDCS: • Down-regulated spinal excitability • Cathodal tsDCS: • Up-regulated spinal excitability

  9. Our research plan • Aim to study effects of tsDCS in 3 phases • Proposed objectives for the first phase: • Establish a reliable &reproducible spinal tsDCS methodology to modulate spinal excitability in healthy subjects

  10. Proposed methods for first phase • Sample size: 10 healthy subjects • Intervention: • Anodal, cathodal or sham tsDCS at T11 2 cm paraspinally • 2mA for 15 mins • Outcome measures: • MEPs will be evoked using trans magnetic stimulation • MEPs, H-reflex and F-wave will be recorded via surface electrodes over gastrocnemius muscle & abductor hallucis muscle bilaterally before & after tsDCS

  11. Reference electrode at infraclavicular area Active electrode T11 2 cm from spinous process Direct current stimulator

  12. Transcranial Magnetic Stimulation MEP amplitude

  13. First phase Anticipated Results • Improved motor output following cathodaltsDCS • Increased MEPs • Increased F wave and • Decreased H reflex

  14. Preliminary results: • Preliminary testing in a single healthy subject suggests that cathodal tsDCS at T11 has greater facilitatory effects on MEPs compared to anodal tsDCS

  15. Scientific plan • Secondphase: • Apply the tsDCS methodology developed in phase one to subjects with SCI • Evaluate modulation of spinal excitability • Same outcome measures as in 1stphase • If measures show favorable findings then we will progress to phase three

  16. Scientific plan • Third Phase: Our long term objective is to evaluate the effects of tsDCS on functional motor recovery, paired with robot-assisted treadmill training in subjects with SCI

  17. Potential Problems • Skin irritation & lesions have been reported following transcutaneous DC stimulation (caution in SCI) • Pain • Duration of the effects • Is there any potential for inducing autonomic dysreflexia?

  18. Discussion • If successful the proposed stimulation technique would mark a significant advancement in the field of SCI rehabilitation • Non-invasive • Inexpensive

  19. Questions

More Related