1 / 11

Recent drag rate measurements

Recent drag rate measurements. Recycler Departmental Meeting November 8 th , 2006 L. Prost, S. Shemyakin. Data taken. Drag rate measurements with the electron beam on axis, +2 kV jumps 100 mA – 400 mA Nominal file (806) Magnetic field realigned recently Modified file 806

raisie
Download Presentation

Recent drag rate measurements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Recent drag rate measurements Recycler Departmental Meeting November 8th, 2006 L. Prost, S. Shemyakin

  2. Data taken • Drag rate measurements with the electron beam on axis, +2 kV jumps • 100 mA – 400 mA • Nominal file (806) • Magnetic field realigned recently • Modified file 806 • SPB01I changed from 13.5 A to 14.5 A • From focusing optimization based on equilibrium changes of a cooled beam at 200 mA (1 mm offset) • Equilibrium to equilibrium • Check ‘old’ SA calibration • Got unexpected data due to slow energy oscillations • Additional output: • Energy vs y-position at R01 • Jumps calibration

  3. Drag rates ranged from 25 to 50 MeV/C per hour All but 6/15/06 data were taken with R38 <4>

  4. Comparison to current density profile: Better agreement ? Unexplained discrepancy (?!?!) Otherwise, good agreement between the two detectors

  5. Data may not be straightforward to interpret because of a wobbling energy Pbars ‘drift’ before the jump

  6. Slow (~6 minute period) energy oscillations are observed • Comparison of the Pelletron voltage variation dU recorded with GVM and the electron energy variations dE calculated from BYR01S • Both signals are averaged over 30 sec • Calibration from a jump (last week presentation) • 0.31 mm/kV • Source of these oscillations is unknown • Voltage regulation loop ? • Temperature ? This is a new observation

  7. Taking advantage of the oscillations as an ‘independent’ measurement of the drag rate for small deviations • The blue curve shows the evolution of the pbar momentum Pipredicted from BYR01 positions Yias where P0 - initial momentum offset  = 33 hr-1 - drag rate coefficient D - coefficient translating the dispersion in BYR01S into the units of MeV/c per mm Y0 - beam position in BYR01S corresponding to an equilibrium energy

  8. Energy jumps calibration/uncertainties 380 V 100 mA, on axis Intended jump (3.67 MeV/c) Error on jump (1s) = 0.23 MeV/c GVMVLT gives 0.11 MeV/c for 1s

  9. Summary/Conclusions/Questions • Fastest drag rates ever recorded • Max ~50 MeV/c per hour for Ib = 300 mA • Better magnetic field alignment • Better alignment with pbars • Smaller emittances ? • Better focusing ? • In particular for 300 mA case • Should not matter on axis • May be slightly better agreement with estimation of the dependence of the drag force with the current density on axis • But still abnormally low drag rate for high electron beam current (e.g.: 400 mA) • ‘Standard’ data analysis (shown here) may be too simple for this set because of the energy wobbling continuously (see following points)

  10. Summary/Conclusions/Questions (cont’) • Slow and relatively large energy oscillations were observed (with pbars and R01 position) for the whole duration of the measurements • New phenomenon/observation • Better (higher) drag force ? • Temperature variations ? • Relatively good agreement between the two ‘measurements’ using a linear model for the drag force • Small oscillations • Possibility to use an applied sinusoid for automated measurement of the drag force • Continue to use R01 position as a spectrometer • Estimated errors for the jump: 0.23 MeV/c (1s) • Based on GVMVLT data, the estimated error is ~half the one calculated with position data • But it is less sensitive

  11. Not a real plan but… • We want to continue (and accentuate) the investigation of the friction force and cooling rates • More measurements will be requested • Visitors from BNL will come to Fermilab in December for that purpose • Very important for their project which goes into review in the Spring • Goals: • Improve cooling (FNAL) • Rates, lifetime,… • Understand cooling (FNAL, BNL,…) !! • Physics contribution of the Electron cooling project

More Related