1 / 36

EWK Cross-sections and Widths

EWK Cross-sections and Widths. Aidan Robson Glasgow University for the CDF and D0 Collaborations. ICHEP, Philadelphia, 30 July 2008. CDF Z  ee. (from Stirling, ICHEP04). 2004, using < 100 pb –1. A high- p T physics programme. Now:.  More challenging t channels

radwan
Download Presentation

EWK Cross-sections and Widths

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EWK Cross-sections and Widths Aidan Robson Glasgow University for the CDF and D0 Collaborations ICHEP, Philadelphia, 30 July 2008

  2. CDF Zee (from Stirling, ICHEP04) 2004, using < 100 pb–1

  3. A high-pT physics programme

  4. Now: More challenging t channels  Differential cross-sections  High-precision measurements of Standard Model parameters

  5. Outline s (ppZ) . Br(Ztt) ds / dy ds / dpT GW GZ(invisible) More challenging t channels Differential cross-sections High-precision measurements of Standard Model parameters

  6. h = 0.6 h= 1.0 pre-radiator shower max h = 2.0 muon chambers hadronic cal  had cal EM cal solenoid EM cal had cal tracker silicon CDF and D0 D0 CDF h=1 2 1 0 Fibre tracker to |h|<1.8 Calorimeter to |h|<4 Muon system to |h|<2 h=2 Drift chamber to |h|<1 Further tracking from Si Calorimeter to |h|<3 Muon system to |h|<1.5 h=3 0 1 2 3 m

  7. W and Z selection Electrons: good EM shower shape small hadronic energy isolated in calorimeter well-matching good track (except far forward) Muons: MIP in calorimeter isolated hits in muon chamber well-matching good track Z selection: 2 oppositely-charged electrons or muons invariant mass consistent with mZ W selection: exactly one electron or muon energy imbalance in reconstructed event, associated with neutrino

  8. Taus at D0 The elements:  calorimeter cluster (cone R<0.5)  energy concentrated in inner cone R<0.3  tracks in cone R<0.3, mass<1.8GeV  EM sub-clusters in finely segmented shower-max layer of calorimeter ET measurement: For E<100GeV, track pT & calorimeter ET are combined for Types 2&3, and single p± energy corrections derived from special hadronic calorimeter simulation. Otherwise track pT used. Three D0 tau categories: Type 1: 1 track, no EM sub-cluster Type 2: 1 track, ≥1 EM sub-clusters Type 3: ≥2 tracks, ≥0 EM sub-clusters Neural net separator trained on variables measuring: isolation shower shape calorimeter–track correlations Type 1 Type 2 Type 3 0 NN output score 1 0 NN output score 1 0 NN output score 1

  9. Ztt Select Ztmth from inclusive muon trigger. Additionally:  pTm > 15 GeV  pTt > 15 GeV  opposite charge  scalar sum pT of t tracks > 15GeV or 5 GeV (types 1&3/2)  NN > 0.9 or 0.95 (types 1&3/2) Backgrounds: corrected for SS–OS ratio in QCD-enhanced sample  QCD (bb) data-driven from same-sign events  EWK backgrounds from MC W+jets corrected for component accounted for in same-sign events mvis = √(Pm + Pt + PT)2 D0 1fb–1 preliminary D0 1fb–1 preliminary D0 1fb–1 preliminary Type 1 Type 2 Type 3 visible mass / GeV visible mass / GeV visible mass / GeV

  10. Ztt Total 1527 events observed, ~20% background s (ppZ) . Br(Ztt) = 247 ± 8(stat) ± 13(sys) ± 15(lumi) pb 2.5% 3.5% 2.3% Values from previous published analysis (PRD 71 072004 (2005))

  11. P1 fq(x1) E+pz E–pz 1 2 x1P1 e+ */Z m √s x1,2 = e±y e– x2P2 P2 fq(x2) Events / 0.1 x - e+ e– CDF CDF CDF y Z rapidity Z production: rapidity y= ln (LO) closely related to parton x:

  12. Z rapidity: shapes Fraction Si tracking efficiency energy scaling factor Tracking |h’| Calorimetry |h|<0.4 0.4<|h|<0.8 Total Acceptance x efficiency 10 ET 60 10 ET 60 |h|<0.8 All h 10 ET 60 10 ET 60

  13. Z rapidity Events Isolation E • Systematics: • Detector material modeling • Background estimates • Electron identification efficiencies • Silicon tracking efficiency • Acceptance

  14. Z rapidity fractional systematic uncertainty (%)

  15. Z pT Measurement of Z pT tests QCD predictions for initial state gluon radiation resummation / parton shower with non-perturbative model pQCD reliable resummation required 0 30 pT(Z) pT(Z) multiple soft gluon radiation RESBOS event generator implements NLO QCD and CSS resummation (with BNLY form-factor) 3-parameter function, global data fit Recent global fits suggest extra small-x form-factor

  16. ppZ0Xe+e–X, LHC:√s=14TeV ppW+Xe+n, LHC:√s=14TeV ppZ0X, Tevatron:√s=1.96TeV ppZ0X, Tevatron:√s=1.96TeV ds /dpT / pb/GeV ds /dpT / nb/GeV |ye| < 2.5 pTe > 25 GeV ET> 25 GeV |y|< 2.5 pTe > 25 GeV pT (Z) / GeV Z pT No small-x broadening (BLNY) With small-x broadening No small-x broadening (BLNY) With small-x broadening ds /dpT / nb/GeV ds /dpT / pb/GeV all y |y|> 2 35 35 0 0 pT(Z) / GeV pT(Z) / GeV e+  Recent global fits suggest extra small-x form-factor – impliespT(Z) broadened at high y e– ATLAS e+ e– D0 35 35 0 0 pT (W) / GeV

  17. Z pT Selection: pT(e1), pT(e2) > 25 GeV |h|<1.1 or 1.5<|h|<3.2 70 < mee < 110 64k events, > 5k for |yZ|>2 Backgrounds: fit mee with templates 1.3–8.5% Regularized unfolding Unfolding method (input MC) Smearing parameters PDF Unfolding method (parameters) QCD background pT dependence of eff. x acc.

  18. Z pT (curves normalised) PRL 100 102002 (2008) without small-x effect: c2/dof = 11.1/11 including small-x effect: c2/dof = 31.9/11 Data does not favour small-x broadening (but no refit of usual 3 parameters has been done)

  19. Z pT The complete spectrum: PRL 100 102002 (2008) Compare 4 models: Resbos with default parameters Resbos with additional NLO–NNLO K-factor NNLO (Melnikov and Petriello) NNLO rescaled at to data at 30GeV/c

  20. W width GW predicted in Standard Model: GWSM = 2091±2 MeV (PDG) Experimentally have access to transverse quantities:

  21. W width  Generator: LO MC matched with Resbos (QCD ISR) and Berends/Kleiss (QED FSR) c2/dof=27.1/22  Fast simulation for templates: electron conversions + showering muon energy loss parametric model of recoil energy (QCD, underlying event + brem)  Tracking scale/resn DG= 17 MeV, 26 MeV mmm (GeV) DG= 54 MeV (ele), 49 MeV (mu)  Backgrounds c2/dof=18/22  Calorimeter scale/resn DG= 21 MeV, 31 MeV DG= 33 MeV DG= 32 MeV mee (GeV) mT (GeV) mT (GeV)

  22. W width PRL 100 071801 (2008) World most precise single measurement GW = 2032 ± 73 (stat+sys) MeV Compare to CDF indirect measurement: (GWSM = 2091 ± 2 MeV) SM value GW (indirect) = 2092 ± 42 MeV NNLO calc From LEP J Phys G 34 2457

  23. Z invisible width GZ(invisible) measured very precisely indirectly from LEP: GZ(invis) = 500.8 ± 2.6 MeV However combined direct LEP measurement: GZ(invis) = 503 ± 16 MeV Tevatron measurement uncorrelated, relies less strongly on theoretical inputs Select single-jet events (ET trigger) Independently measure s(Z+1jet) . Br (Z  ll) from high-pT lepton trigger Selection:  ET > 80 GeV  ETjet > 80 GeV second jet ET<30 allowed but ≥ 3 jets ET>20 rejected GZ(inv) GZ(ll) s(Z+1jet) . Br (Z  inv) s(Z+1jet) . Br (Z  ll) = Nobs – Nbck s(Zll+1jet) . L = Must be corrected for different acceptance of ‘1-jet’ selection in Znn versus Zll (applied after lepton removal)

  24. Z invisible width EWK ‘background’ includes Znn prediction Measureds(Zll+1jet) = 0.555 ± 0.024 pb GZ(inv) GZ(ll) = 5.546 ± 0.506 ~ equal contributions from EWK bck, QCD bck and s(Zll+1jet) GZ(inv) = 466 ± 42 MeV Nn = 2.79 ± 0.25

  25. Summary W and Z cross-section measurements underpin the Tevatron high-pT physics programme Dedicated measurements are harnessing the high statistics datasets:  improving tau identification  testing higher-order calculations and PDFs and probing QCD  making precision measurements of SM parameters

  26. Backup Backup

  27. longer Q2 extrapolation smaller x (W James Stirling)

  28. D0 Z rapidity

  29. CDF ds/dy

  30. ppZ0X, Tevatron:√s=1.96TeV ppZ0X, Tevatron:√s=1.96TeV ds /dpT / nb/GeV all y |y|> 2 ds /dpT / pb/GeV pT(Z) / GeV Z pT • Nadolsky et al: • global fits to HERA and fixed-target data suggest increased intrinsic pT carried by proton constituents, for interactions involving only a small fraction of proton’s momentum  they insert extra factor in differential cross-section ; pT(Z) broadened at high y e+ e– CDF

  31. ppZ0Xe+e–X, LHC:√s=14TeV ppW+Xe+n, LHC:√s=14TeV ds /dpT / nb/GeV ds /dpT / pb/GeV |ye| < 2.5 pTe > 25 GeV ET> 25 GeV |ye| < 2.5 pTe > 25 GeV pT (Z) / GeV e+ e– ATLAS Z pT • LHC: beam energies ~7x higher than Tevatron • Probing new part of phase space • Tevatron forward detectors map on to LHC central detectors • Problem! W/Z production is a benchmark

  32. Z pT C-P Yuan

  33. Indirect GW

  34. without small-x effect: pT < 5GeV/c: c2/dof = 0.8/1 pT<30GeV/c: c2/dof = 11.1/11 including small-x effect: pT < 5GeV/c: c2/dof = 5.7/1 pT<30GeV/c: c2/dof = 31.9/11

  35. u u p d d u p u W± l± n

More Related