1 / 3

Best chiller plant maintenance services|Khatana Enterprises

Our organization have been actively engaged in providing Chiller Plant Maintenance Services in Gurgaon,Haryana, India. The daily log is still the first step toward maintaining an efficiently-run chiller plant. These services are rendered by our most skilled professionals using latest tools and machine. Our precious clients can avail these Chiller Plant Maintenance Services from us at rock bottom prices.See More:-http://www.khatanaenterprises.com/services1cpm.html

Download Presentation

Best chiller plant maintenance services|Khatana Enterprises

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Khatana Enterprises: Ways to Amplify Chiller Efficiency Chiller plant maintenance is considered a vital issue to operate the entire mechanism in an effective method. Chillers over and over again symbolize a plant's single biggest electric load. Operating a chiller plant in its crest performance saves energy but also lends a hand in diminishing maintenance costs. No doubt, the chiller efficiency has enhanced exponentially during the last decade. This became possible due to the arrival of new refrigerants as well as microprocessor controls, in addition to enhanced compressor along with motor design. On the other hand, ultra-modern chillers have narrower lenience, so that service and conservation are more fundamental than ever for keeping them operating at mountainperformance. Chiller presentation varies notably with operating conditions. Full-load performance is not a first-rate indicator of overall routine, since chiller plants infrequently operate at full load. In its place, part load performance is significant to superior overall chiller plant performance. The Director of Khatana Enterprisesshares a few vital tips that can lend a handin keeping the riding of chiller plantshigh.

  2. Take care of condenser water Condenser water circles using open cooling resources, like atmospheric cooling towers, need water treatment to avert fouling. Erosive conditions, for instance, sand flowing throughout the tubes at high velocity, may hollow tubes, diminishing tube effectiveness. Untreated water can harm tubes, piping along with other materials. A cooling tower blow down is the mainly effective way to eliminate solids as well as contaminants. When a sensor distinguishes high water conductivity, a mechanical valve leaves some water and its pack of dissolved and poised solids. A visual scrutiny also is a good, though less precise, indicator of water quality. You are advised to study chilled water loops once a year for all- purpose water quality and substantiation of corrosion. Keep tubes uncontaminated Heat transfer has the maximum single consequence on chiller show. Large chillers can have higher than five miles of condenser as well as evaporator tubes, so high heat transfer is elementary to maintaining competence. Chiller efficiency turns down rapidly when tubes become stained. Contaminants like raw materials, scale, sludge, algae and other adulteration augment thermal resistance and shrink performance. These contaminants mount up on the water side of heat transport surfaces in both closed- as well as open-loop systems. Pollution occurs regularly over time, depending on the class and warmthof the water used. overall

  3. The approach of the compressor temperature, the disparity between the heat of the fluid leaving the warm exchanger and the infiltration heat of the refrigerant being cooled or heated, is a first-class indicator of heat transfer competence. An amplified advance temperature is a chief indicator that heat transfer effectiveness is decreasing. An exact log sheet will disclose when temperatures begin to change from resourceful levels. Condenser tubes ought to be brushed, unsoiled instead of chemically cleaned, at least once a year with a mechanical rotary-cleaning engine to keep them liberatedfromcontaminants. Keep on a daily basis log The everyday log is yet the primary step in maintaining a competently run chiller plant. A log builds an account of operating settings, which includes flow rate, fluid level, pressure as well as pressure. Even though microprocessor controls are recording extra of these statistics, there is no replacement for a written log aspect findings from day by day assessment of controls in the chiller room. Reference:- http://goo.gl/FJJ5zO

More Related