An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. GAFCHROMICApplicationsPrince KIRYAMANISP

  2. GAFCHROMIC EBT2 Self developing - eliminates the processor Energy independent dose response Near tissue equivalent Dose range: Red Channel 1 – 800 cGy Green Channel: 8 – > 50 Gy 8”x10” and 14”x17” sheets High spatial resolution Can be handled under indoor lighting Scan with either flatbed scanner or medical scanner Water resistant – usable in water phantoms High uniformity (+/- 3% maximum in dose) Economical Blue Channelto be used for film uniformity correction for even higher accuracy in future releases of the FILMQA software.

  3. BallCubeII Film and Phantom Placement

  4. Procedure

  5. FilmQA in Six Easy Steps • Import Calculations • From treatment planning system • Import Films • Using flatbed or medical scanner • Register • Automatic orientation of films • Calibrate • Convert to dose images • Evaluate • Compare calculations to films • Create Reports • Customizable in HTML Format

  6. Ball Cube II Film Analysis marker locations film CAL film scan 3D dose matrix .TIF file .DCM file .XML file FilmQA analysis

  7. GAFCHROMIC RTQA2 1010 1010P 111 1417

  8. GAFCHROMIC XR-QA2 Can be handled under indoor lighting 8”x10” or 10”x12” High spatial resolution Dose range: 0.1 – 100 cGy Scan with flatbed scanner Can be analyzed with the FILMQA and FILMQA-XR softwares.

  9. GAFCHROMIC XR-QA2

  10. GAFCHROMIC XR-CT

  11. GAFCHROMIC XR-M2

  12. GAFCHROMIC XR-RV3 1 1417

  13. FilmQA-XR – Single Click!

  14. RADView Badge Radiologically equivalent to soft tissue Transparent to X-rays at the kVp settings for CT scans Measures the surface dose from X-ray treatments Self-developing radiation sensitive film Calibrated for dose 1.2” x 2.4”

  15. Thank you