1 / 11

Systems Engineer: Ren Fanucchi Phone #: 650-745-1934

AT&T Voice Over Managed Services Wisconsin Interscholastic Athletic Association, Inc. (WIAA) IP#: IP09075893 Service Line: MISBIB BIB / BVoIP IP Flex Reach IP-PBX ANALOG Vo MIS IP Local Site Documentation Package. Customer Contact: Shipping Address: City / State: Phone :.

parley
Download Presentation

Systems Engineer: Ren Fanucchi Phone #: 650-745-1934

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. AT&T Voice Over Managed Services Wisconsin Interscholastic Athletic Association, Inc. (WIAA) IP#: IP09075893 Service Line: MISBIB BIB / BVoIP IP Flex Reach IP-PBXANALOG VoMIS IP Local Site Documentation Package Customer Contact: Shipping Address: City / State: Phone: Todd Clark 5516 Vern Holmes Drive Stevens Point, WI. 54481 715-344-8580 For any T1.5 Circuit Questions or To Schedule a Test & Turn-up: Please call Between hours of 8 am - 5 pm Eastern. Please allow 48 hours for scheduling. Call PTE/IM:Michael Smith Phone #:1-888-613-6330 Pmts #4, #1 Systems Engineer: Ren Fanucchi Phone #: 650-745-1934

  2. SHEET NO. 2 3 4 5 6 7 & 8 9 10 11 DESCRIPTION TABLE OF CONTENTS EQUIPMENT ORDER LIST (EOL) AT&T / Edgemarc Hardware & Cable Detail ROUTER CABLING AND ADDRESSING DIAGRAM IP Flex Reach Analog FXS Ports BIB Base Unit to Add-On Device Connectivity Chart 12-Port PoE (Base Unit Router) Back Panel. 12-Port PoE (Base Unit Router) Front Panel. 8-Port ATA (4508E) Analog Expansion Module. REVISION 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 TABLE OF CONTENTS Attention Customer: The equipment you received has already been configured. Please do not attempt to re-configure this Equipment.

  3. EQUIPMENT ORDER LIST (EOL) Attention Customer: The equipment you received has already been configured. Please do not attempt to re-configure this Equipment.

  4. AT&T / Edgemarc Hardware & Cable Detail 4508T4WPoE 12 Port Base Router Hardware & Cables included with each device 4508E (8 Port ATA) Analog Expansion Module Hardware & Cables included with each device. • Power Pack 1.0 Amps. • - A/C Power cord ( 6ft. ). • 2 long “L” shaped mounting brackets & 6 small philips mounting screws. • 3 Mounting holes to unit, 2 Elongated holes for rack mounting. • Brackets may be pre-installed. • - One V.90 Cable. Brown in color. • 14 feet in length, (RJ11 male- RJ11 male) with a tape labeled V.90 • at each end. • - One Ethernet Cable. Burnt Orange in color. • 14 feet in length, (RJ45 male- RJ45 male) with a tape labeled Ethernet • at each end. • - 1 plastic bag containing one black 4” pull tie and six 5/8” philips screws. • 1 plastic bag containing one 1” square piece of foam tape, and plastic • cable holder for pull tie. • -1 faceplate template for wall mounting. • - Power Pack 3.75 Amps. • A/C Power cord ( 6 ft.). • Wireless Antenna. • 2 “L” shaped mounting brackets & 8 small philips • mounting screws. • 4 holes for Mounting to unit, 2 Elongated holes for rack • mounting. • Brackets may be pre-installed. • One T1 cable. Grey in color. 14 feet in length, • (RJ45 male - RJ45 male) with a tape labeled T1 at each end . • - One V.90 Cable. • Brown in color. 14 feet in length, (RJ11 male - RJ11 male) with • a tape labeled V.90 at each end. Attention Customer: The equipment you received has already been configured. Please do not attempt to re-configure this Equipment.

  5. ROUTER CABLING DIAGRAM IP PBX - IP Local Public Media Address: (Loopback): 12.209.106.18 4 2 3 1 Host Name 4508E (ATA) ATA #1 USWIAASTEWI07S WAN IPAddress:12.87.215.138/30 Voice VLAN 100: 1.1.2.1 /24 Data VLAN 200: 192.168.4.1 /22 Public Network Customer VLAN 300: 12.45.43.16 /28 Management VLAN 500 12.45.43.0/28 Management IP of the 4508T4W12.45.43.1/28 Internal IP Address: 172.16.10.10 Antenna Range 300 Feet Base Router Host Name USWIAASTEWI01R 4508T4WPoE12 T1 NETWORK FACILITY Ethernet WAN port not used 56941-025-262 (ISE642-025) x 4 USB Ports Not Used AT&T T1.5 CKT ID: DHEC 191928 ATI - Port 1 V.90 TO 2-WIRE DIAL-UP LINE To Be Provided GCBSR2-J11J11-22mo4 Maintenance Option: M4 (7X24, Four Hour Response)

  6. BIB Base Unit to Add-On Device Connectivity Chart *Add-On to Base Unit cable type - Straight Ethernet RJ45-RJ45 Attention Customer: The equipment you received has already been configured. Please do not attempt to re-configure this Equipment.

  7. BIB Base Unit to Add-On Device Connectivity Cont… Attention Customer: The equipment you received has already been configured. Please do not attempt to re-configure this Equipment.

  8. 12-Port PoE Base Unit Router Front Panel 6 4 2 3 5 1 FXS ports Circled. 6 Ports used for connecting to voice devices. Analog Phones and Equipment Ports 1-6 (Circled) outlined in green)) are to be connected to phones, analog PBX/key systems and fax machines for the VoIP service provide by Office in a Box. During the telephone install process you will be directed to connect to your phones and/or fax machines. IP Flex Reach Analog FXS Ports Attention Customer: The equipment you received has already been configured. Please do not attempt to re-configure this Equipment.

  9. 12-Port PoE (Base Unit Router) Back Panel 1). Connect a gray RJ-45 14' T1 straight-through cable to the region denoted as “F” of the 24-Port PoE Base Unit Router Back Panel. 2). Connect the other end to a T1 demarcation point.

  10. 12-Port PoE (Base Unit Router) Front Panel 3). If you will be using the wireless LAN, connect the wireless antenna to the front of the Base Unit Router as shown in region “A” of the 12-Port PoE Base Unit Router Front Panel. 4). Connect the appliance from region B, 12-Port PoE Base Unit Router Front Panel to an AC outlet.

  11. 8-Port ATA (4508E) Analog Expansion Module WAN Port (PVID 100) LAN Port 3 (PVID 500) 1). Connect one end of the orange RJ-45 cable provided with the analog expansion module to the highest numbered port (located in region “B” of the 24-Port PoE Base Unit Router Back Panel of the switch. Connect the other end to the Ethernet port (labeled as “A” in Figure 9. 8-port analog expansion module) on the analog expansion module. 2). If more than one analog expansion module will be used, connect another RJ-45 cable to the highest numbered port (located in region “B” of the 24-Port PoE Base Unit Router Back Panel of the switch. Connect the other end to the Ethernet port (labeled as “A” of the 8-port analog expansion module) on the analog expansion module. Connect up to three 8-port analog expansion modules, repeating steps 1 and 2 accordingly. Following the guidelines at the beginning of this section, connect each appliance from region B of the. 8-port analog expansion module to an AC outlet

More Related