G-M 计数器特性研究

G-M 计数器特性研究. 廖捷 10300720045 2012.12.25. 目录. GM 计数管结构和原理 原先的实验电路及现象 改进 后的实验电路 改进 前后计数率变化. GM 计数管的结构. 惰性气体 高压 电源加载至阳极 柱状对称的 电场 阳极附近电场最强. 引自 《 近代物理实验补充讲义 》. GM 计数管的基本原理. 气体电离. 雪崩放电. 输出脉冲. 死亡时间. 引自 复旦大学物理教学实验中心. 实验仪器. 改变 X 放射源电流 计数率 R~I. 原先的实验电路结果. U hv =522V G=7 R=25 KΩ

palti
Download Presentation

G-M 计数器特性研究

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. G-M计数器特性研究 廖捷 10300720045 2012.12.25

  2. 目录 GM计数管结构和原理 原先的实验电路及现象 改进后的实验电路 改进前后计数率变化

  3. GM计数管的结构 • 惰性气体 • 高压电源加载至阳极 • 柱状对称的电场 • 阳极附近电场最强 引自《近代物理实验补充讲义》

  4. GM计数管的基本原理 • 气体电离 • 雪崩放电 • 输出脉冲 死亡时间 引自复旦大学物理教学实验中心

  5. 实验仪器 • 改变X放射源电流 • 计数率R~I

  6. 原先的实验电路结果 Uhv=522V G=7 R=25KΩ Ux=19.1KV

  7. 为什么会出现非线性? 正离子鞘减弱电场 死亡时间td 到达某一半径R0 刚好引起放电 向阴极扩散 恢复时间tr 分辨时间τ 脉冲能引起计数 分辨时间τ引起了漏记! 正离子到达阴极

  8. 漏记修正 单位时间内 记录m次, 每次计数后τ 时间内发生漏记 实际应计数n次

  9. 原先的实验电路结果拟合 得到分辨时间:τ=268.1μs

  10. GM计数器分辨时间

  11. RC弛豫过程 RC充电曲线 RC放电曲线

  12. 改变负载电阻(RC) R=100KΩ R=25KΩ

  13. 微分电路的作用 输出的尖脉冲波形的宽度与R*C有关,R*C越小,尖脉冲波形越尖,反之则宽。 引自《模拟电子技术基础》

  14. 实验电路改进

  15. 微分处理后的结果 Uhv=522V G=7 R=25KΩ Ux=19.1KV DIV=6 得到分辨时间: τ=83.6μs

  16. 改进前、后的计数率变化 分辨时间减小: τ =268.1μs τ’=83.6μs 在高计数率情况下相性关系良好

  17. 改进前、后的计数率变化

  18. 改变微分常数的变化

  19. 总结 前置电路的RC常数影响了分辨时间 引入微分电路,减小了分辨时间,改善计数特性 微分常数越小,信号越窄,幅度越小 计数阈值很有可能不是0.6V

  20. 谢谢观看! 廖捷 10300720045 2012.12.25