§ 7 红外吸收光谱的实验技术

§ 7 红外吸收光谱的实验技术. 一、仪器的基本结构及工作原理. 1 、红外辐射光源 2 、放置样品的样品室 3 、色散红外辐射的单色器 4 、接受辐射的检测器 5 、电子放大及数据处理系统. 二、测定技术. 试样的制备技术. 1 、气体样品. 2 、液体样品. 3 、固体样品. ( 1 )、压片法. 把 1~2mg 固体样品放在玛瑙研体中研细,加入 100~200mg 磨细干燥的碱金属卤化物(多用 KBr )粉末,混合均匀后,加入压模内,在压片机上边抽真空边加压,制成厚约 1mm ,直径约为 10mm 左右的透明片子,然后进行测定。.

odele
Download Presentation

§ 7 红外吸收光谱的实验技术

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. §7 红外吸收光谱的实验技术 一、仪器的基本结构及工作原理 1、红外辐射光源 2、放置样品的样品室 3、色散红外辐射的单色器 4、接受辐射的检测器 5、电子放大及数据处理系统

  2. 二、测定技术 试样的制备技术 1、气体样品 2、液体样品

  3. 3、固体样品 (1)、压片法 把1~2mg固体样品放在玛瑙研体中研细,加入100~200mg磨细干燥的碱金属卤化物(多用KBr)粉末,混合均匀后,加入压模内,在压片机上边抽真空边加压,制成厚约1mm,直径约为10mm左右的透明片子,然后进行测定。 由于KBr的吸湿性,在~3330cm-1和~1650cm-1处会产生杂质峰。

  4. (2)、糊状法 将固体样品研成细末,与糊剂(液体石蜡油)混合成糊状,然后夹在两窗片之间进行测定,用石蜡做糊剂不能用来测定饱和碳氢键的吸收情况,可以采用六氯丁二烯代替石蜡油做糊剂。 液体石蜡是一种精制过的长链烷烃,只有在3000~2850cm-1区的C-H伸缩振动、~1456cm-1和~1379cm-1的C-H变形振动以及720 cm-1的CH2的平面摇摆振动的吸收。 六氯丁二烯在4000~1700cm-1无吸收, 1700~600cm-1有多个吸收峰。

  5. (3)、薄膜法 把固体样品制成薄膜来测定,薄膜的制备有两种: A、直接将样品加热,熔融样品涂制或压制成薄膜; B、先把样品溶于挥发性溶剂中制成溶液,然后滴在盐片上,待溶剂挥发后,样品遗留在盐片上而形成薄膜。