1 / 14

UV-vis data and NORS validation server

UV-vis data and NORS validation server. F. Hendrick, B. Langerock, M. Van Roozendael, and M. De Mazière. Belgian Institute for Space Aeronomy (IASB-BIRA), Brussels, Belgium. NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 1. Context.

nikki
Download Presentation

UV-vis data and NORS validation server

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UV-vis data and NORS validation server F. Hendrick, B. Langerock, M. Van Roozendael, and M. De Mazière Belgian Institute for Space Aeronomy (IASB-BIRA), Brussels, Belgium NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 1

  2. Context • To develop and implement a web-based application for validation of MACCII products using the NORS data products (NORS WP8) MACC output at 0, 6, 12, 18, 24h UT NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 2

  3. 1. Temporal interpolation • For UV-vis data, three different cases need to be considered: • Total ozone columns (90° SZA AM and PM) • Stratospheric NO2 columns and profiles (90° SZA AM and PM) + diurnal variation • Products from MAX-DOAS observations (every ~30’) NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 3

  4. Temporal interpolation: total ozone • Choose a characteristic time-window (e.g., 6h as for FTIR): MACC output 6h 6h Time 90°SZA AM observation 90°SZA PM observation NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 4

  5. Temporal interpolation: stratospheric NO2 90°SZA PM 90°SZA AM MACC-II output Scaling factor x_MACCII(LTDOAS) = x_MACCII (LTMACCII) . [ x_model(LTDOAS)/x_model(LTMACCII) ] with x= NO2 VCD or [NO2] at altitude z NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 5

  6. NORS NO2 photochemical correction tool • ‘Off-line’ calculation of look-up tables of NO2 profile diurnal variation using of the BIRA photochemical box model PSCBOX • Model calculations for the following scenarios: altitude (24 levels), latitude (18 values covering 85°N→85°S by 10° step), longitude set to 0, months 1-12 • For each month, use of the SLIMCAT chemical and meteorological fields corresponding to the middle of the month averaged over a period of 10 years (2000-2009) • Look-up tables of NO2 profile diurnal variation in ASCII • Creation of an interpolation routine in FORTRAN to extract the needed scaling factors NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 6

  7. Sensitivity tests (1) March 15th chemical field and p, T profiles averaged over 10 years (2000-2009) NO2_model(LTDOAS) / NO2_model(LT) March 15th 2000 NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 7

  8. Sensitivity tests (2) March 15th chemical field and p, T profiles averaged over 10 years (2000-2009) NO2_model(LTDOAS) / NO2_model(LT) March 15th 2005 NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 8

  9. Sensitivity tests (3) denoxification NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 9

  10. NORS NO2 photochemical correction tool • ‘Off-line’ calculation of look-up tables of NO2 profile diurnal variation • Use of the photochemical box model PSCBOX • Model calculations for the following scenarios: altitude (24 levels), latitude (18 values covering 85°N→85°S by 10° step), longitude set to 0, months 1-12 • For each month, use of the SLIMCAT chemical and meteorological fields corresponding to the middle of the month averaged over a period of 10 years (2000-2009) • For polar regions in late fall, winter, early spring, additional look-up tables are needed for denoxification conditions; the choice of LUTs (denoxification conditions or not) could be based on the measured NO2 columns NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 10

  11. Temporal interpolation: MAX-DOAS products • Smaller time-window due to the strong short-term variation: 1h 1h MACC output Time MAX-DOAS observations (every ~ 30’) NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 11

  12. 2. Spatial interpolation • As for FTIR, calculate the location of the effective airmass of every measurement • Interpolate the four surrounding MACC-II model data to this effective airmass location: Is it relevant to proceed like this with UV-vis measurements ? Do we have tools for such calculations ? NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 12

  13. 3. Smoothing and vertical gridding Profile comparisons: • MACC-II profile xMACC must be regridded to the vertical grid of the NORS profile • The MACC-II data is smoothed with the averaging kernel of the NORS measurement using: • xs,MACC = xa,NORS + ANORS (xMACC – xa,NORS) • IF DOFS < 5, one defines partial column boundaries in between which there is about one DOF. Partial column boundaries should be defined by the PI of the instrument NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 13

  14. 3. Smoothing and vertical gridding Column comparisons: • MACC-II profile xMACC must be regridded to the vertical grid of the NORS profile • The MACC-II data is smoothed with the column averaging kernel of the NORS measurement using: • Cs,MACC = Ca,NORS + (xMACC – xa,NORS) • Suitable for OEM-based retrievals but what we do for total ozone and stratospheric NO2 column retrievals (no a priori data used) ? NORS/NDACC UV-VIS meeting, Brussels, 3-4 July 2012 14