How to manage cabinets with very low-density cooling requirements?

AnIT Rack is a power hub with computing capabilities that uses a lot of electricity. It generates a fair share of heat that requires continuous monitoring and regulation with cooling infrastructure solutions. Thus, a cooling strategy is essential to ensure the overall efficiency of anIT Infrastructure installed inside the cabinet.<br>For more detais: https://www.netrackindia.com/

Download Presentation

How to manage cabinets with very low-density cooling requirements?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. How to manage cabinets with very low-density cooling requirements? https://www.netrackindia.com/

  2. Cabinets with very low-density cooling requirements AnIT Rack is a power hub with computing capabilities that uses a lot of electricity. It generates a fair share of heat that requires continuous monitoring and regulation with cooling infrastructure solutions. Thus, a cooling strategy is essential to ensure the overall efficiency of anIT Infrastructure installed inside the cabinet. Server density and heat generation According to secondary research, the average temperature of an IT Rack should vary between 18 and 27 degrees Celsius with a relative humidity between 20 to 80 percent. Based on the servers and the size of the Cabinet, heat generation varies. For example; a low-density server generates less heat. Hence, it is relatively simple and cost-efficient to manage cabinets with low power consumption and heat generation. Strategize cooling solutions Traditional Server Room uses air conditioners as a cooling technique. While couple of Smaller set ups will have very low density of Cooling requirement. Currently, the cooling technique for such a small setup areSelf-Cooled and Self-Contained Racks. https://www.netrackindia.com/

  3. Cabinets with very low-density cooling requirements • AC Rack deployment • NetRack being a leading rack enclosure manufacturer, designed Self-Cooled and Self-Contained Racks with air conditioning installed within the rack itself to house critical IT equipment. • Small setups such as; shops, cafeterias, and warehouses mostly lack air conditioning and to separately create optimal cooling for a smaller setup is expensive. NetRackintroduced the Panel Mount self-cooling server rack. The AC Rack offers a cooling capacity of 0.7kW to 7kW along with the following features. • It requires minimal maintenance. • It is ideal for remote locations. • Smaller Foot Print • We at NetRack ensure that the AC racks are manufactured with the highest quality steel sheets certified by ISO 9001 | ISO 14001 | ISO 27001 | ISO 45001 Manufacturing and Quality management system. Hence the self-cooling racks are reliable, durable, and cost-efficient. https://www.netrackindia.com/