지진 하중을 받는 구조물의 수정된 분산뱅뱅 제어기법을 이용한 MR Damper 제어

한국지진공학회 츤계학술발표 연세대학교 2002 년 3 월 23 일. 지진 하중을 받는 구조물의 수정된 분산뱅뱅 제어기법을 이용한 MR Damper 제어. 조 상 원* : KAIST 건설 · 환경공학과 박사과정 김 병 완 : KAIST 건설 · 환경공학과 박사과정 김 운 학 : 한경대학교 토목공학과 교수 이 인 원 : KAIST 건설 · 환경공학과 교수. CONTENTS. Introduction Semi-Active Control

nedaa
Download Presentation

지진 하중을 받는 구조물의 수정된 분산뱅뱅 제어기법을 이용한 MR Damper 제어

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 한국지진공학회 츤계학술발표 연세대학교 2002년 3월 23일 지진 하중을 받는 구조물의 수정된 분산뱅뱅 제어기법을 이용한 MR Damper제어 조 상 원* : KAIST 건설·환경공학과 박사과정 김 병 완 : KAIST 건설·환경공학과 박사과정 김 운 학 : 한경대학교 토목공학과 교수 이 인 원 : KAIST 건설·환경공학과 교수

  2. CONTENTS • Introduction • Semi-Active Control • Proposed Control Algorithm • Numerical Example • Conclusions and Further Studies Structural Dynamics & Vibration Control Lab., KAIST, Korea

  3. Introduction • Recent Earthquakes • Kobe, Japan (1995) 5,400 of death and 1.5 trillion won of damage • Gebze, Turkey (1999) 14,491 of death and 13 trillion won of damage • Chi-Chi, Taiwan (1999) 2,161 of death and 9.2 trillion won of damage To increase the safety and reliability, structural control is required Structural Dynamics & Vibration Control Lab., KAIST, Korea

  4. Structural Control Strategies • Active control • Use external control force to reduce the responses • Large external power • The problem of reliability under earthquake • Active Mass Damper (AMD) • Passive control • Increase the capacity of energy dissipation of structure • No external power • No adaptability to various external load • Lead Rubber Bearing (LRB) Structural Dynamics & Vibration Control Lab., KAIST, Korea

  5. Semi-active control • Change the characteristics of control devices • Small external power • Reliability of passive system with adaptability of active system • Variable-orifice damper, MR/ER damper Structural Dynamics & Vibration Control Lab., KAIST, Korea

  6. Semi-Active Control Devices • Variable-orifice damper Feng and Shinozuka (1990), Kawashima et al. (1992) • Variable-friction damper Akbay and Aktan (1990), Kannan et al. (1995) • Semi-active impact damper Masri and Yang (1973), Papalou and Masri(1996) Structural Dynamics & Vibration Control Lab., KAIST, Korea

  7. Controllable fluid damper • Electrorheorogical fluid damper (ER damper) Ergott and Masri(1992) • Magnetorheorogical fluid damper (MR damper) Carlson et al. (1994) Table 1 Properties of MR and ER Fluids Structural Dynamics & Vibration Control Lab., KAIST, Korea

  8. MR Damper • Characteristics of MR fluid With Magnetic Fields Without Magnetic Fields Wires to Electromgnet Diaphragm MR Fluid Coil Bearing & Seal Accumulator Structural Dynamics & Vibration Control Lab., KAIST, Korea

  9. x (1) • Modeling of MR damper • Model of the parallel-plate MR damper (Jansen et al. 2000) f c0 • Voltage dependence of the damper parameters (2) v : commanded voltage Indirect control command is used Structural Dynamics & Vibration Control Lab., KAIST, Korea

  10. Objective and Scope To develop an efficient semi-active control strategies considering the characteristics of MR damper Structural Dynamics & Vibration Control Lab., KAIST, Korea

  11. Semi-Active Control • Semi-Active Control Algorithms • Karnopp et al. (1974) “Skyhook” damper control algorithm • Feng and Shinozukah (1990) Bang-Bang controller for a hybrid controller on bridge • Brogan (1991), Leitmann (1994) Lyapunov stability theory for ER dampers • McClamroch and Gavin (1995) Decentralized Bang-Bang controller Structural Dynamics & Vibration Control Lab., KAIST, Korea

  12. Inaudi (1997) : Modulated homogeneous friction algorithm for a variable friction device • Sack et al. (1994), Dyke (1996) : Clipped optimal controllers for semi-active devices Structural Dynamics & Vibration Control Lab., KAIST, Korea

  13. Clipped-Optimal Control (Dyke et al. 1996) • Optimal control with clipped algorithm • Optimal control • State-space equation • Cost function (3) (4) Structural Dynamics & Vibration Control Lab., KAIST, Korea

  14. (5) • Optimal control algorithm K : solution of Ricatti equation (6) • Control force is linear to the state of structure- No consideration of saturation Structural Dynamics & Vibration Control Lab., KAIST, Korea

  15. Clipped algorithm • Indirect control command to MR damper • Control voltage v , instead of control force (7) fc : calculated optimal control force fi : control force of MR damper H : Heaviside step function vi : control voltage Structural Dynamics & Vibration Control Lab., KAIST, Korea

  16. Proposed Control Strategy : Clipped Decentralized Bang-Bang Control (CDBBC) • Decentralized Bang-Bang Control • To use full capacity of MR damper • To consider the saturation of MR damper • High speed switching control command • Clipped algorithm • Indirect control command Structural Dynamics & Vibration Control Lab., KAIST, Korea

  17. Decentralized Bang-Bang Control (McClamroch and Gavin, 1995) • Based on Lyapunov stability theory • Lyapunov function V(z) • Derivative of Lyapunov function (8) (9) Structural Dynamics & Vibration Control Lab., KAIST, Korea

  18. (10) • Control law which minimize Eq.(9) • Approximate sign function • Modified decentralized bang-bang control (11) (12) where Structural Dynamics & Vibration Control Lab., KAIST, Korea

  19. Clipped algorithm • Indirect control command to MR damper • Control voltage v , instead of control force (13) fc : calculated CMBB Control force fi : control force of MR damper (nonlinear) H : Heaviside step function vi : control voltage Structural Dynamics & Vibration Control Lab., KAIST, Korea

  20. Block diagram of proposed control algorithm Structure MR Damper ` Clipped Algorithm Modified DBB Control Clipped Modified Decentralized Bang-Bang Control (CMDBBC) Structural Dynamics & Vibration Control Lab., KAIST, Korea

  21. Numerical Examples • Six-Story Building (Jansen and Dyke 2000) f2 MR Damper v2 f1 LVDT v1 LVDT Control Computer Structural Dynamics & Vibration Control Lab., KAIST, Korea

  22. System data • Mass of each floor : 0.277 N/(cm/sec2) • Stiffness : 297 N/cm • Damping ratio : each mode of 0.5% Structural Dynamics & Vibration Control Lab., KAIST, Korea

  23. x • Damper modeling and parameters F-f , Bouc-Wen Model Structural Dynamics & Vibration Control Lab., KAIST, Korea

  24. 3 Modes of MR damper • Passive-off : input Voltage = 0 V • Passive-on : input Voltage = 2.5 V • Semi-Active : switching on and off according to control algorithm Structural Dynamics & Vibration Control Lab., KAIST, Korea

  25. Structural responses by CMDBBC (Under El Centro Earthquake, at 3rd floor) Uncontrolled CMDBBC Structural Dynamics & Vibration Control Lab., KAIST, Korea

  26. Unsaturated condition under El Centro earthquake Structural Dynamics & Vibration Control Lab., KAIST, Korea

  27. Discussions • Maximum measured control forces : 24.03 N • Capacity of MR damper : 29N (1.8% of total weight) Unsaturated condition !! Structural Dynamics & Vibration Control Lab., KAIST, Korea

  28. Saturated condition under magnified El Centro earthquake Structural Dynamics & Vibration Control Lab., KAIST, Korea

  29. Conclusions • Proposed Clipped modified decentralized bang-bang control reduce the structural responses from the uncontrolled value • Performance of proposed is not better than clipped optimal control under unsaturated condition • For the strong earthquake (i.e. saturated condition), clipped optimal control is not better than others Structural Dynamics & Vibration Control Lab., KAIST, Korea

  30. Further Studies • Clipped Modified Decentralized Bang-Bang Control • Improve the performance • Apply to full-scale MR damper • Experimental Studies • Shaking table test • Full-scale MR damper test Structural Dynamics & Vibration Control Lab., KAIST, Korea