An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Testing of MEMS Materials Using Thermal Actuation, AFM Image Correlation and Capacitance Measurement Students: Y. Chen, B. Peng, and Z. He Mentor: Y. Zhu March 20, 2003

  2. Introduction • The reliability of MEMS devices is a major issue and it can only be addressed by direct measurements on small specimens with dimensions on the same order of magnitude as the fabricated micro-devices • Knowledge on bulk material behavior fails to describe material response in this size regime • Various techniques have been developed in the past to address the issues of mechanical integrity and evaluation of the elastic properties of polysilicon. • Tensile tests are less vulnerable to geometry-induced errors and the measurements are easier to interpret from an error analysis point of view

  3. A Actuation Pads S Sensing Pads Specimen Thermal Actuator Load Sensor -Vo +Vo S High-Resolution AFM Imaging of Specimen Film S V A A Vsense S Experimental setup Scheme of the MEMS tensile testing device Three components: Thermal actuator , specimen, load sensor

  4. 1 micron Optical image of the microtensile specimen and the MEMS testing device. AFM image shows the surface roughness and grain size of the specimen

  5. Experiment Step 1: Characterize the system error by scanning the same area at zero loading to eliminate the results of the shifting and minimize the measuring error Step2: Using AFM records of deformed and undeformed specimen configurations to measure the strainsof the surface of the specimen

  6. Step 1.Scanning the same area without load Two AFM images of the undeformed specimen surface. The images are scanned at the same location with a frequency of 2 Hz. The scanning area is 5x5 mm2 . It is very hard to find the difference of the two images by naked eyes.

  7. exx, 10 mm x 10 mm exx, 10 mm x 10 mm Analyze the displacement by DIC method(1) exx =0.000521, eyy = -0.0484

  8. eyy,, 5 mm x 5 mm exx, 5 mm x 5 mm Analyze the displacement by DIC method (2) exx =0.000569, eyy = -0.0509

  9. exx, 2 mm x 2 mm eyy, 2 mm x 2 mm Analyze the displacement by DIC method(1) exx =0.000518, eyy = -0.0533

  10. Step 2: Y X (a) Strain of undeformed specimen at x direction (c) Strain of deformed specimen at x direction 1 mm (b) Strain of undeformed specimen at y direction (d) Strain of deformed specimen at y direction DIC results of strain analysis on both undeformed and deformed specimen. The four images are at the same location. X is the direction of the load.

  11. Calculated Strain:

  12. Simulation

  13. Conclusion • The absence of surface developed charges makes the use of a probe microscope possible in the regime of small interaction forces between the film and the AFM probe. • This technique is less vulnerable to geometry-induced errors and the measurements are easier to interpret from an error analysis point of view. • Although there is an initial drifting of the AFM image at zero load, the strain of the specimen can be compensated by subtract the measured strain by the initial shifting • Future work will be conducting measurements at various voltages (loads) to find the sensitivity of the strain measurement.