1 / 69

Learning Objectives:

mohawk
Download Presentation

Learning Objectives:

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. “Architectural Nexus” is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credits(s) earned on completion of this program will be reported to AIA/CES for AIA member. Certificates of Completion for both AIA members and non-AIA members are available upon request. This program is registered with AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any material of construction or any method or manner of handling, using, distributing, or dealing in any material or product. Questions related to specific materials, methods, and services will be addressed at the conclusion of this presentation.

  2. Learning Objectives: • Understand how LEED is developing with recent changes proposed in LEED v4 • Understand how LEED v4 restructures credits • Review new LEED categories • Understand how the new Materials and Resources credits impact industry standards

  3. GBCI Credit • This presentation is pre-approved for one hour of LEED-specific continuing education by the Green Building Certification Institute. • Everyone will need to self report at gbci.org under 'my credentials.‘ • Leave your e-mail at the sign-in table for certificates.

  4. When will projects be allowed to register for LEED v4? A: RIGHT NOW! (Since November 2013 at Greenbuild) When will registration for v2009 end? A: June 1, 2015. When will LEED credential exams be updated? A: LEEDv4 exams start June 30, 2014 B. LEED 2009 (v3) exams sunset June 15, 2014

  5. Image Credit: Natural Capital

  6. BD+C (10 categories) ID+C(3 categories) 4 Rating Systems EB:O+M(6 categories) NC (2 categories) 110 points total 40-49 points CERTIFIED 50-59 points SILVER 50-59 points GOLD 80-110 points PLATINUM

  7. - NEW - NEW - CHANGES - CHANGES - CHANGES Credit Categories - MAJOR CHANGES - CHANGES - NO CHANGES - NO CHANGES

  8. Question #1 • What is one of the new categories in LEED v4?

  9. Integrative Process

  10. v2009 DIDN’T EXIST v4 IPc1 • NEW CREDIT • ENCOURAGES EARLY ANALYSIS OF ENERGY AND WATER SYSTEMS TO INFORM DESIGN

  11. CHANGES IN SUSTAINABLE SITES LOCATION & TRANSPORTATION v4 SUSTAINABLE SITES v4 SUSTAINABLE SITES v2009 16 26 10

  12. Location & Transportation

  13. v4 v2009 DIDN’T EXIST LTc1 • NEW CREDIT • ENCOURAGES EARLY ANALYSIS OF ENERGY AND WATER SYSTEMS TO INFORM DESIGN

  14. v4 LTC5 v2009 SSc4.1 • CREDIT RENAMED FROM “ALTERNATIVE TRANSPORTATION – PUBLIC TRANSPORTATION ACCESS” • MULTIPLE THRESHOLDS TO REWARD VARYING TRANSIT SERVICE LEVELS .25mi WALKABLE DISTANCE = .25mi RADIUS = .25mi

  15. v4 LTc8 v2009 Sc4.3

  16. Sustainable Sites

  17. NEW RENAMED / REORGANIZED

  18. v2009 DIDN’T EXIST v4 SSc1 • NEW CREDIT • ENCOURAGES EARLY ANALYSIS OF SITE CONDITIONS TO INFORM DESIGN

  19. v2009 SSc7.1 v4 SSc4 v2009 SSc7.2 • COMBINATION OF “HEAT ISLAND EFFECT – NONROOF” AND “HEAT ISLAND EFFECT – ROOF” • UPDATED

  20. SACRAMENTO

  21. v2009 SSc8 v4 SSc6 • INCLUDED THE BUG RATING METHODOLOGY AS A PRESCRIPTIVE WAY TO MEET THE EXTERIOR LIGHTING REQUIREMENTS • ADDED LIGHTING ZONE 0 • INCLUDED EXTERIOR SIGNAGE REQUIREMENTS • ADDED EXEMPTIONS

  22. Question #2 • What importance does the heat island effect have on mechanical systems and architectural design?

  23. Water Efficiency

  24. NEW

  25. No irrigation beyond 2-yr. maximum establishment period, OR • 30% minimum irrigation water reduction for peak watering month. • Building Water Use • 20% minimum indoor water reduction. • New fixtures: Watersense labeled • Appliance and Process Water Use • Standards for Appliances – ENERGY STAR, CEE • Standards for Processes: • No once-through potable water cooling for appliances that reject heat • Cooling Towers and Evap. Condensers: Equip with additional meters and alarms to reduce water use • Permanent water meters for potable water – manual or automated • Share 5 years of data with USGBC

  26. Conduct a one-time potable water analysis in cooling towers and evaporative condensers to measure concentrations of 4 minerals + conductivity • 1 point: Limit cooling tower cycles to avoid exceeding maximum concentration levels. • +1 point: Increase treatment OR use 20% recycled non-potable water • Permanent Water Meters for Two or More Subsystems: • Irrigation • Indoor plumbing fixtures • Domestic hot water • Large boilers • Reclaimed water • Other process water

  27. Question #3 • Why is it important to distinguish between potable and non-potable water use?

  28. Energy & Atmosphere

  29. NEW NEW

  30. Reference Guides: • ASHRAE Guidance 0-2005 and ASHRAE Guideline 1.1-2007 for HVAC&R Systems • NIBS Guideline 3-2006 for exterior closures • Addition of exterior closures in OPR and BOD documents • Can be reviewed by member of design or construction team • Creation of Facilities Maintenance Plan

  31. ASHRAE 90.1-2010 • More efficient Baseline • Must meet before counting Renewable Energy • Option 1: Energy Simulation • 5% NC, 3% MR, 2% CS • Retail must include process load equipment • Option 2: Prescriptive Compliance: ASHRAE 50% Energy Design Guide • Option 3: Prescriptive Compliance: Advanced Buildings’ “Core Performance” Guide • Less then 100,000 SF • Not Healthcare • Data Centers must be 5% over baseline by energy cost and IT equipment cost • Includes cooling units for computer and data rooms and critical equipment • 2% of 5% energy savings through building power cooling infrastructure • Include process loads from unregulated load and IT equipment load

  32. Meters for five years • Share with USGBC • Path 1: is similar to LEED 2009 • Path 2: Additional point by developing monitoring-based procedures and identify measurement points to evaluate performance of systems AND/ OR (2pts) • Option 2: Envelope Commissioning • Data Centers that select Path 2 Option 1 must: • Review of OPR and BOD before 50% CD’s • Back check review comments and • Review at 95% • Larger projects review at start of DD’s, before 50% CDs, and at 100%

  33. Makes energy generation more efficient, grid reliability, reduces greenhouse gasses • Participate in DR program w real time fully automated if Initiated by external DR programmer • 1 yr 10% peak energy demand • Plan for meeting commitment and scope of work for Cx to test system OR if DR not available (1pt) • Install infrastructure for future program • Plans for commitment and Cx • Contact utility about future participation • Whole building monitoring of energy sources and • Monitoring of energy use 10% of building

  34. Addition of carbon offsets for scope or 2 emissions on a metric ton of carbon dioxide Green-e Climate or equivalent certified • Must be for offsets for projects within US • 50% and 100% reduction

  35. Question #4 • What is the biggest change in Energy & Atmosphere when compared to LEED 2009?

  36. Materials & Resources

  37. NEW

  38. New: • Now can Include wood waste converted to fuel (bio-fuel) in the calculations • Waste-to-energy systems may be considered waste diversion if listed directives are followed • Option 1: Divert 50% and three material streams (1 point) • Option 2: Divert 75% and four material streams (2 points) • Option 3: Reduction of total waste material (2 points) • Do not generate more than 2.5 pounds of construction waste per square foot of the building's floor area.

  39. Chico Gateway Museum: 114.72 tons generated = 229,440 pounds 9,698 s.f. 23.68 psf generated! (68% diverted) Fausel Professional Building: 158.24 tons generated = 316,480 pounds 18,637 s.f. 16.98 psf generated! (82% diverted) NRF Production Support Complex: 303.4 tons generated = 606,800 pounds 89,964 s.f. 6.74 psfgenerated! (65.5% diverted)

  40. BUILDING PRODUCT DISCLOSURE AND OPTIMIZATION CREDITS: • ALPHABET SOUP • LCAs EPDs HPDs C2C Athena Impact Estimator

  41. ALPHABET SOUP • Life Cycle Assessment (LCA) • Environmental Product Declaration (EPD): • Environmental Report of product performance based on Life Cycle Assessment Image: Edge Environment

  42. PRODUCT TRANSPARENCY • Step 1: Disclosure of impacts • Step 2: Optimization of impacts - Image: GreenScreen

More Related