1 / 19

xDSL Line Tester Modem EX 30M

ELEKTR NIKA. xDSL Line Tester Modem EX 30M. EX 30M is a handheld, cost-effective test set to check DSL services and the copper cable capability.

mingus
Download Presentation

xDSL Line Tester Modem EX 30M

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ELEKTRNIKA xDSL Line Tester Modem EX 30M EX 30M is a handheld, cost-effective test set to check DSL services and the copper cable capability. It is a remote controlled reference modem which can be controlled by an android application running on a tablet PC or smart phone through Bluetooth connection.. Internet

  2. ELEKTRNIKA xDSL System Group Selection 126 Selectable System Groups ●ADSL ●VDSL For details click on the corresponding keys

  3. ELEKTRNIKA ADSL Modem Test 126 By means of the “Golden Modem” of EX 30M we can check the proper operation of DSLAM. EX 30M offers two test options: ● Synchronization Test providing information on the training process and the actual state of line. In this mode there isn’t data transfer between the local and public network. ●Automatic Test providing detailed information on the quality of data transfer between the local and public network. The actual connection profile and the LAN parameters can be modified before starting the test. For details click on the corresponding keys.

  4. ELEKTRNIKA ADSL Synchronization Test When the synchronization test mode is selected the Modem Status display appears and EX 30M automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. The status indicator shows the actual state of synchronization: RED The line is in Idle State (No synchrony) GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed Finishing the training process EX 30M provides detailed line diagnosis.

  5. ELEKTRNIKA Automatic ADSL Test When the automatic test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. xDSL connection Indicator RED No synchrony GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization iscompleted Link IP Status Indicator RED There is no data transfer YELLOW Trying to establishdata transfer GREEN Successful data transfer ETET 30 provides: ●Ping & Trace test ●Detailed line diagnosis ●Browsing possibility For details click on the corresponding key.

  6. ELEKTRNIKA Editing of ADSL Profile EX 30M supports the synchronization in all ADSL modes and connection types. Supported ADSL Modes As a default EX 30M supports the synchronization in all ADSL modes but the operator can disable one ore more of them. Selectable connection types: In ADSL mode EX 30M supports five connection types.

  7. ELEKTRNIKA LAN Settings The IP parameters of the modem can be modified here.

  8. ELEKTRNIKA Ping & Trace Test The ping tests can manage:●the URL format ●IP address format The number of PING requests and the size of PING packets can be set. To call the Trace Test window click on the Trace key

  9. ELEKTRNIKA Traceroute Test The Trace Test can manage: ●the URL format ●IP address format

  10. ELEKTRNIKA Line Diagnosis In this mode EX 30M provides detailed line diagnosis in graphic and numeric forms.

  11. ELEKTRNIKA VDSL Modem Tests By means of the “Golden Modem” of EX 30M we can check the proper operation of DSLAM. EX 30M offers two test options: ● Synchronization Test providing information on the training process and the actual state of line. In this mode there isn’t data transfer between the local and public network. ●Automatic Test providing detailed information on the quality of data transfer between the local and public network. The actual connection profile and the LAN parameters can be modified before starting the test. For details click on the corresponding keys. For details click on the corresponding keys.

  12. ELEKTRNIKA VDSL Synchronization Test When the synchronization test mode is selected the Modem Status display appears and EX 30M automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. The status indicator shows the actual state of synchronization: RED The line is in Idle State (No synchrony) GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization is completed Finishing the training process EX 30M provides detailed line diagnosis.

  13. ELEKTRNIKA Automatic VDSL Test When the automatic test mode is selected the Modem Status display appears and ETET 30 automatically starts the synchronization. The training process takes a while. During this time the actual modem status information is displayed. xDSL connection Indicator RED No synchrony GREEN (blinking) The training is in progress GREEN (Continuous) The synchronization iscompleted Link IP Status Indicator RED There is no data transfer YELLOW Trying to establishdata transfer GREEN Successful data transfer ETET 30 provides: ●Ping & Trace test ●Detailed line diagnosis ●Browsing possibility For details click on the corresponding key.

  14. ELEKTRNIKA Editing of VDSL Profile EX 30M supports the synchronization in all VDSL modes and connection types. Supported VDSL Modes As a default EX 30M supports the synchronization in all VDSL modes but the operator can disable one ore more of them. Selectable connection types: In VDSL mode EX 30M supports3 connection types.

  15. ELEKTRNIKA LAN Settings The IP parameters of the modem can be modified here.

  16. ELEKTRNIKA Ping & Trace Test The ping tests can manage:●the URL format ●IP address format The number of PING requests and the size of PING packets can be set. To call the Trace Test window click on the Trace key

  17. ELEKTRNIKA Traceroute Test The Trace Test can manage: ●the URL format ●IP address format

  18. ELEKTRNIKA Line Diagnosis In this mode EX 30M provides detailed line diagnosis in graphic and numeric forms.

  19. THANK YOU FOR YOUR ATTENTION!