1 / 41

Bruce Mayer, PE Licensed Electrical & Mechanical Engineer BMayer@ChabotCollege.edu

Engineering 36. Real Life Application. Bruce Mayer, PE Licensed Electrical & Mechanical Engineer BMayer@ChabotCollege.edu. AL-3100 S2 Seismic Loading CG Measurements. Bruce Mayer, PE Dir. System Engineering 23Jul01. System FootPrint. MacroMicro Main Unit. Loader/UnLoader.

milek
Download Presentation

Bruce Mayer, PE Licensed Electrical & Mechanical Engineer BMayer@ChabotCollege.edu

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Engineering 36 Real LifeApplication Bruce Mayer, PE Licensed Electrical & Mechanical EngineerBMayer@ChabotCollege.edu

  2. AL-3100S2 Seismic LoadingCG Measurements Bruce Mayer, PEDir. System Engineering23Jul01

  3. SystemFootPrint

  4. MacroMicro Main Unit

  5. Loader/UnLoader

  6. 3100 MiniEnvironment Housing

  7. Results, MiniEnvironment • Total Weight/Mass = 25.3 kN, 260 kg, 570 lb • Maximum Leg Load = 1.33 kN (300 lb) • Center of Gravity Offset from Geometric Center • CG 3% to Left (toward side A-D) • CD 2% Forward (toward end A-B) • CG offset Attributed to Fan Motor Inverter-Drive Unit

  8. Leg Loading & Ctr of Gravity Test Apparatus C D Load Cell at Each Level-Leg A B

  9. Main Unit Center of GravityTest: X-Axis Tilt Main Unit Center of Gravity TestY-Axis Tilt

  10. Load/Unload Unit Center of GravityTest: X-Axis Tilt

  11. Load/Unload Unit Center of GravityTest: X-Axis Tilt BEFORE • Level • 0.04° Tilt AFTER • Level • 3.17° Tilt

  12. LCGD-1k Load Cell Test – No Load - 23Jul01 3100 SEMICon-West01 MiniEnvironment Crate Load Cell Lift Truck 13.65 Vdc Excitation Power Source NO Load OutPut Signal (mVdc)

  13. LCGD-1k Load Cell Test – Full Load - 23Jul01 3100 SEMICon-West01 MiniEnvironment Crate Load Cell Lift Truck 13.65 Vdc Excitation Power Source Loaded OutPut Signal (mVdc): 8.8 mV•(50lb/mV)  440 lbs

  14. XY CG Calc • Measure With Load Cells • Total SubSytem Weight • Reaction loads at All Floor Contact Points • Calc using RA & RB • Solve for W and Y1 • Check W by

  15. Vertical CG (z-CoOrd) Determination After Before

  16. Vertical CG Determination • Use XY CG Results • TIP System, and Measure Angle with Digital Protractor • Note that for Higher CG, the Restoring Lever Arm is Shortened More • Working the Geometry, and Doing the Math Find for Small Tilt Angles :

  17. 3x00 S2-§19Seismic Protection Bruce Mayer, PEDir. System Engineering19Feb02 • EarthQuake • Magnitude 8.0 • Kurile Islands • 03Dec1995

  18. 3x00 Seismic Protection Analysis Plan • Measure/Calc Weight and Center of Gravity • Consult S2/§19 for Lateral Loading Criteria (0.63g) • Consult Mechanical Design Drawing for Seismic Structural-Element Location & Configuration • Use Newtonian Vector Mechanics to Determine Force & Moment Loads • Use Solid-Mechanics Analysis to Determine Fastener (Bolt) Stresses • Use Mechanical-Engineering & Materials Properties to determine Factors of Safety

  19. BMayer

  20. S2-0200 Test SystemAL3120F, s/n 111001 3x00 S2Testing: Tatsuno Japan, Dec01 3x00_S2S8_Tatsuno_PhotoDoc_0112.ppt

  21. 3x00 Seismic Loading & Geometry BMayer

  22. Loading Geometry Detail

  23. Leg Loading & Ctr of Gravity Test Apparatus Load Cell atEach Level-Leg Jack to TiltFrame Unit P7310022a_mm_tilt_full.JPG A

  24. Center of Gravity Tilt-Testing: Before DigitalProtractor P7310050_Ul_gage_before.JPG

  25. Center of Gravity Tilt-Testing: After DigitalProtractor P7310055_me_GageAfter.JPG

  26. OverTurning Analysis • Analysis Parameters: • Worst Case → SHORTEST Restoring-Moment Lever-Arm • Lever Arms= 582mm, 710mm, 776mm (see slides 4&5) • Vertical (resisting/restoring) Acceleration of 0.85gper SEMI S2 §19.2.4 • Horizontal (overturning) Acceleration for non-HPM equipment of 0.63g per §19.2.2 • Results → Safe From Overturning WithOUT Restraints (but not by much!) 3x00_Seismic_Analysis_0202.xls

  27. Bracket Stress Analysis • Analysis Parameters • Assume Failure Pointat M6 or M10 Bolts • FOUR (4) Angle Brackets With a total of 8 Connecting & Anchor Bolts, Resist Shear • Two Bolts Per Point, Each Bolt Bears 50% of Load • Bolt Axial-PreLoad is negligible (Snug-Fit) • Shear Load Per Restraint Point = 500lb/2.22kN • Use Von Mises Yield Criteria: Ssy = 0.577Sy • Results 3x00_Seismic_Analysis_0202.xls

  28. 3x00 S2-§19- Appendix A - R5-1: Seismic Protection CheckList

  29. X See Analysis By B. Mayer PE: file 3x00_Seismic_Analysis_0202.xls X Factor of Safety 10x for Shear-Load

  30. S2-0200, §19 R5-1: Seismic Protection CheckList cont.1 X Anchors are well secured, and system is connected by Flexible Electrical & CDA conduits X FrameWork is Rigid Relative to Module Weight Given 0.63g acceleration X FrameWork is Rigid Relative to Module Weight Given 0.63g acceleration X Customer Supplied M10 Floor Anchors Should have Need Pull-Out Rating 1.1 kN (250 lb) Ref: ASTM Standard E 488 X NO attached Equipment

  31. S2-0200, §19 R5-1: Seismic Protection CheckList cont.2 X No Large and Brittle Components X X NOT APPLICABLE by Q.B3

  32. S2-0200, §19 R5-1: Seismic Protection CheckList cont.3 X No Hazardous Piping. The CDAir piping is flex-line X X X

  33. S2-0200, §19 R5-1: Seismic Protection CheckList cont.4 X X

  34. OLYMPUSIntegrated Technologies America, Inc. 3x00 S2-§19- Appendix B -Anchor-Bolt PullOut Ratings

  35. B. Mayer Research: 1911 25-Jul-01 • Ref: http://www.powers.com/manual/23pb.htm • 23.7 Performance DataTesting conducted according to ASTM Standard E 488. Ultimate Load Capacities - Carbon Steel Power-Bolt™

  36. OLYMPUSIntegrated Technologies America, Inc. 3x00 S2-§19- Appendix C -Engineering Mechanics Analsysis

More Related