html5-img
1 / 18

Environmental analysis applying inner-shell spectroscopies and the molecular orbital theory

Environmental analysis applying inner-shell spectroscopies and the molecular orbital theory. Jun Kawai Kyoto University. Acknowledgements S. Kunimura, N. Sasaki Asahi Glass Foundation MTA-JSPS Joint Resaerch Project. Portable TXRF with Hamamatsu Photonics tube (1W).

maleah
Download Presentation

Environmental analysis applying inner-shell spectroscopies and the molecular orbital theory

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Environmental analysis applying inner-shell spectroscopies and the molecular orbital theory Jun Kawai Kyoto University Acknowledgements S. Kunimura, N. Sasaki Asahi Glass Foundation MTA-JSPS Joint Resaerch Project

  2. Portable TXRF with Hamamatsu Photonics tube (1W)

  3. http://www.x-ray.co.jp/imp_pico.html http://www.rigaku.co.jp/products/p/xfex0015/ 5 kg 37kg www.fisichem.com 70kg Non-mono X-ray tube 1 W Detection limit 1 ng August 2007 http://www.technos.co.jp/products/index.html

  4. X-ray XRF + Scat. Non-TXRF XRF X-ray TXRF K: 6 ng Ca,Sc,Ti,V,Cr,Mn,Fe: 8 ng Ni: 24 ng S: 435 ng TXRF:Yoneda & Horiuchi (1971)

  5. TXRF Yoneda & Horiuchi (1971) Kunimura Horiuchi April, 2007

  6. Vanadium containing mineral water Blank 20 x 7 mL 9 ng of V

  7. 20 mL x 0.5 ppm Cr K: 6 ng Ca, Sc, Ti, V, Cr, Mn, Fe: 8 ng, Ni: 24 ng S: 435 ng

  8. 20 mm 100 mm 0.8 mm 1 mm 5 mm Egorov: X-Ray Spectrom. 33 (2004)360 Si wafer Al strips

  9. Conventional XRF TXRF H.J. Sanchez: Nucl. Instr. and Meth. in Phys. Res. B 194 (2002) 90 Detector www.fisichem.com Sample Reflectors

  10. Waveguide Mode Formation 2 3 Air Mo Be Mo Substrate

  11. ~150 mm … X-ray 50 mm X-rays ~25 mm … 50 mm W Si Music plate lens X-ray wave guide Ca - Fe 4 ng, Ni 12 ng

  12. Detection limit for various TXRF spectrometers

  13. Donau Kamogawa Kyoto

  14. Standard soil sample (KKS) Pb 1077 ppm As 408 ppm Se 314 ppm Cd 614 ppm Hg 72 ppm 50 kV X-ray tube zoom

  15. Conclusions • Non-mono X-ray tube 1 W, TXRF: Detection limit 1 ng at August 2007 • X-ray optics: wave guides, music lens, discharge X-ray tube, … • Quantum chemistry-Pb La/Lb ratio…

More Related