1 / 8

RCT Shift Report 24 June, 2009

RCT Shift Report 24 June, 2009. Michalis Next shifter: Christos. RCT shift report. 1. July 1, 2009. 18-crate pattern test known problems. Exclusively run by Kira Known problems EM Crate 4 :2 bit stuck low (GCT)

makala
Download Presentation

RCT Shift Report 24 June, 2009

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RCT Shift Report24 June, 2009 Michalis Next shifter: Christos RCT shift report 1 July 1, 2009

  2. 18-crate pattern test known problems • Exclusively run by Kira • Known problems • EM Crate 4 :2 bit stuck low (GCT) • Adjusted GCT cable, went away ,back on 12 March,gone on 27th March back 17 April • EM crate 15:all noniso 4 bit stuck low (came went came)(GCT) went away after adjustments on GCT -reappeared same day • J/S crate 13, card 0 regions 0/1—512 bit stuck low(intermittent occurrence) • J/S crate 15, card 1, regions 0/1 2 bit stuck low (GCT) • Went away after readjustments by GCT but reappeared later • J/S crate 15, card 3,regions 0/1-- 32 bit stuck low (GCT) • Appeared after GCT Intervention • J/S crate 15, cards 5,6, regions 0,1 –unplugged source card • J/S crate 0 –cards 5/6 unplugged source card • HF: crates 0,15,all –unplugged source cards • HF crate 5 Crads 1/3 have 64 bit stuck low • Appeared Feb 23d,gone April 14th , reappeared May 22 RCT shift report 2 July 1, 2009

  3. Pattern tests: New Problems • EM Crate 1 , card 6 Possible sharing problem • Needs more investigation RCT shift report 3 July 1, 2009

  4. DCS status summary • More or less everything went OK • A spike in temperature for 5 mins last Friday • A network outage for 1 min • When we restarted RCT the FSM had dead status • Known problem with CERN DCS FSM framework • Needs restarting the FSM node • Asked Bobby to do it • Everything fine after that RCT shift report 4 July 1, 2009

  5. Shift phone • Call On Tuesday 23:00 • Trigger shifter asked if they were using the correct RCT key • Replied yes but Pam also verified it • Call ON Tuesday 00:10 • RCT failed to configure • Manually destroyed cell and asked them to retry • It worked even if they didn't believe it would RCT shift report 5 July 1, 2009

  6. Data quality monitoring • CRUZET started Monday Morning • Masked SCs and Fibers:Monday • HF:RCT 11 eta=30 phi odd • ECAL:RCT 0-8 , RC 4 & 5, ieta =17 ,phi odd and even for EE-/EB- edge • ECAL: RCT crate 15, card 6 region 1 ECAL • ECAL EE+8 masked , ieta 18-28 phi even and odd • More masking due to high rates • Masked RCT 5 RC 3 eta 9-13,15,16 phi odd(starting run 101644) • Masked RCT 5 RC 6 eta=25-28 odd and phi even (starting 101649) • Masked RCT 5 , RC3 eta 14 after 101649 due to operator error RCT shift report 6 July 1, 2009

  7. Wednesday Current masks:  a - HF: RCT 11 eta=30 phi odd    b - ECAL: RCT 0-8, RC 4 & 5, ieta = 17, phi odd and even for EE-/EB- edge   c - ECAL: RCT Crate 15 Card 6, region 1 ECAL   d - ECAL: EE+8 masked, ieta 18-28 phi even and odd   e - HCAL: RCT 5 RC 3 eta 9-16 phi odd (except eta = 14 in region 1 before run 101649)   f - HCAL: RCT 5 RC 6 eta 25-28 phi odd and phi even 

  8. According to Marc /data are not in DBS yet so we could not run the DQM today! DQM Runs RCT shift report 8 07/01/09

More Related