1 / 7

Latest KEK Beam Test Results from Canada, France, Germany, Japan, and the Philippines

This report presents the interim results of the DoubleFit and FTPC analyses from various institutions including KEK, TUAT, and universities across Canada and Japan. Key findings include measurements of resolution and pad response function under an ArIso220 setup. Results indicate a drift resolution of s0 = 0.91 ± 19 mm (Neff = 13.2 ± 0.8) and FTPC extrapolated resolution of s0 = 0.102 ± 38 mm at 2m and B=4T (Neff = 25.6 ± 5.6). Extensive comparisons of phi and theta track angles are also detailed.

lobo
Download Presentation

Latest KEK Beam Test Results from Canada, France, Germany, Japan, and the Philippines

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KEK Beam Test Results Canada, France, Germany, Japan, Philippines KEK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., Japan MSU, Philippines, Carleton Univ.of Ottawa,Univ. de Montréal, Canada, MPI, Germany, DAPNIA-CEA, Saclay, IN2P3-LAL and IPN, Orsay, France Dan Burke 20/12/05

  2. Contents • DoubleFit and FTPC interim results (ArIso220) • Resolution • Pad Response Function • Phi + Theta comparisons

  3. DoubleFit Resolution ArIso 220V/cm s0= 91+-19 mm Neff = 13.2 +- 0.8

  4. FTPC Resolution s0= 102+-38 mm Resolution extrapolated to 170 mm @ 2m and B=4T Neff = 25.6+-5.6 Resolution (mm) Drift Distance (mm)

  5. Pad Response Function Amplitude Distance (mm)

  6. FTPC and DoubleFit Phi ArIso 220V/cm Track Angle (degrees) Track Angle (radians)

  7. FTPC and DoubleFit Theta ArIso 220V/cm Track Angle (degrees) Track Angle (radians)

More Related