UV Electrical Cabinet (Machines 16 and above). General. General (Cont.). General (Cont.). The power cabinet is responsible for the following functions: Supplying voltages & controlling the UV lamp system Supplying voltages & controlling the cooler unit

lisagray
Download Presentation

UV Electrical Cabinet (Machines 16 and above)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UV Electrical Cabinet (Machines 16 and above)

  2. General Confidential

  3. General (Cont.) Confidential

  4. General (Cont.) • The power cabinet is responsible for the following functions: • Supplying voltages & controlling the UV lamp system • Supplying voltages & controlling the cooler unit • Supplying voltages & controlling the extraction unit Confidential

  5. General (Cont.) • Wiring Notes: • Blue wire: 24VDC • Red wire: 110VAC • Black wire 400VAC Confidential

  6. Electro Magnetic Compatibility Filter A1.1 Q1.1 -Mains circuit breaker Earth Leakage Relay Q2 -Transformer breaker K2-UV Main Contactor Units Description Confidential

  7. Units Description (cont.) • Safety Switch Relay K9: • Verify that the UV lamphead cover is closed and enables the UV main contactor K2. Confidential

  8. Fuses • F1: 110 V out from the transformer, 2 Amps fuse • F2: 24VDC power supply output protection, 2 Amps fuse • F3: Shutter open signal to the shutter valve, 1.6 Amps fuse Fuses Confidential

  9. Fusses E.M Contact 1&2 Shutter Close 1 ShutterClose2 Over Tem’ (Lamp) Lamp pressure Shutter Open Safety Relays Confidential

  10. K3 K4 K5.1 K5.2 Units Description (cont.) • UV lamp High Voltage contactors: • Enable the high voltage to the lamp by levels (30%-100%). Confidential

  11. Units Description (cont.) • Overload Relays: • Q6.11 - Cooler Pump • Q6.12 - Cooler Fan1 • Q6.22 - Cooler Fan2 • Q7 - Extract Fan Frequency Inverter A7 • Contactors: • K6.11-Cooler Pump Contactor • K6.12-Cooler Fan1 Contactor • K6.22-Cooler Fan2 Contactor Confidential

  12. Extraction Fan Frequency Inverter A7 Units Description (cont.) • Extraction fan frequency inverter A7: • Controls the air extraction flow rate, depending on the UV lamp power. Confidential

  13. Units Description (cont.) • PLC Panel Confidential

  14. PLC Panel Inputs: • R1: Shutter ON, from the machine • R3, R4 and R5: UV power bits, from the machine • R6: Extraction fan operation indication, from A7 (Inverter) Confidential

  15. PLC Panel (Cont.) • Inputs: • R7: Cooler pump or cooler fans trip indication • R8: Lamp head pressure switch, from the UV lamp head • R9: Lamp head cover status (closed/opened) indication • R10: Transformer Contactor Operation K2 • R12: Alarm reset button • V2: 24VDC • 0VD: 0VDC Confidential

  16. PLC Panel (Cont.) • Inputs and outputs: • I1: Transformer breaker • I2: Shutter opened indication, from the UV lamphead • I3: Shutter closed indication, from the UV lamphead • I4: Lamp head over temperature indication Confidential

  17. PLC Panel (Cont.) • Inputs and outputs (cont.): • I5: Emergency switch from the machine • I6: Cooler over temperature indication, from the thermal switch in the Cooler • I7: UV lamp power indication • I9: Cooler low level indication • I10: UV ON signal from the machine • 0VD: 0VDC • QA1: Output signal to the extraction fan frequency inverter A7 Confidential

  18. PLC Panel (Cont.) • Outputs: • Q1: Extraction fan frequency inverter A7 • Q2: Operating power to the UV main contactor K2 • Q3, Q4 and Q5: Output power for enabling the high voltage contactors • Q6: Enabling cooler pump and fans Confidential

  19. PLC Panel (Cont.) • Outputs Signals: • S1: UV ready signal to the machine • S2: Shutter open signal to the shutter valve • S3, S4 and S5: UV fault signal to the machine Confidential

  20. Transformer • Receives an input of 380-480VAC. • Converts the voltage to 110VAC. Confidential

  21. 24VDC Power Supply • Receives an input voltage of 110VAC. • Converts the voltage to 24VDC for the PLC. Confidential

  22. High Voltage Transformer • Receives an input voltage of 230VAC. • Converts the voltage to 2000VAC for the UV lamp. Confidential

  23. Capacitors • Supply the high voltage to the UV lamp Confidential

  24. Electrical Connections • XPC1: Connected to the cooler. • XPC2: Connected to the cooler. • XPPT: Connected to the UV lamp head. • XPF7: Connected to the extraction fan. Confidential