Microwave Measuring System, LB 356-456 Micro-Moist PowerPoint Presentation
Download Presentation
Microwave Measuring System, LB 356-456 Micro-Moist

Microwave Measuring System, LB 356-456 Micro-Moist

163 Views Download Presentation
Download Presentation

Microwave Measuring System, LB 356-456 Micro-Moist

- - - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript

  1. 1

  2. 2

  3. 3

  4. 4

  5. Microwave Measuring System, LB 356-456 Micro-Moist Moisture Content in Coal is an important parameter: Preparation-Regulate Moisture Content Handling-Dust-Ice Transport-Weight Trading-Weight Calorific Value 5

  6. Microwave Measuring System, LB 356-456 Micro-Moist • Microwave Transmission Techniques are the most accurate • method of determining moisture content of Coal • Attenuation/Area Weight • Phase Shift/Area Weight • Phase Shift and or/Attenuation 6

  7. Microwave Measuring System, LB 356-456 Micro-Moist Attenuation measurement can provide accuracy up to 1wt% moisture Temperature dependence error Bulk Density dependence error Particle size dependent error Conductivity dependent error 7

  8. Microwave Measuring System, LB 456 Micro-Moist Phase Shift Measurement: or (Combined Attenuation and Phase Shift) Independent of Temperature of Coal Independent of Particle Size variations INTEGRAL Area Weight Compensation Accuracy of 0.2 wt% moisture achievable 8

  9. Microwave Measuring System, LB 356-456 Micro-Moist Principle of Operation 9

  10. Microwave Measuring System, LB 354-356-456 Micro-Moist • The choice of 2.7-3.4 GHz frequency range: • Measurement of bulk, not surface. This provides a representative measurement • The temperature coefficient of free water crosses zero at 3 GHz • Attenuation due to ionic conductivity (salt content,…) is reduced at higher • frequencies • Frequency analysis over the frequency range provides phase measurement greater • than 360 deg with plausibility control 10

  11. Microwave Measuring System, LB 356 Micro-Moist 11

  12. Microwave Measuring System, LB 356 Micro-Moist Coal Preparation Plant: 12

  13. Microwave Measuring System, LB 356 Micro-Moist Coal Preparation Plant management reported precision of 0.4% moisture (one sigma RMS) 13

  14. Microwave Measuring System, LB 456 Micro-Moist • Product Improvements: • Reference cable can be replaced by short link if Toconstant • PT-100 Temperature Compensation with direct connection • Detector to Evaluation Unit uses FSK (Frequency Shift Keying) 14