sFHENIX HADRON CALORIMETER 90 degree Support Structure Analyses

This analysis examines the modifications made to the sFHENIX Hadron Calorimeter 90° support structure, including the attachment of a vertical frame to blue connecting belts via a new transparent element. The ANSYS module is used for detailed analyses, including mesh and deformation studies, as well as equivalent stress calculations. Key findings include the deformation of the absorber structure due to asymmetry and the location of maximum stress on the bottom absorber plate separator.

langlinais
Download Presentation

sFHENIX HADRON CALORIMETER 90 degree Support Structure Analyses

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. sFHENIX HADRON CALORIMETER 90 degree Support Structure Analyses DUE TO SYMMETRICITY ½ STRUCTURE TAKEN IN ANALYSES ORIGINAL MODULE HAS BEEN MODIFYED: VERTICAL FRAME NOW NOT ATTACHED TO ABSORBER R. Ruggiero, A.Gordeev

  2. sFHENIX HADRON CALORIMETER 90 degree Support Structure Analyses MODULE MODIFICATION: VERTICAL FRAME ATTACED NOW TO BLUE CONNECTING BELTS THROUGH NEW ELAMENT (TRANSPARENT) R. Ruggiero, A.Gordeev

  3. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE . ISO VIEW. R. Ruggiero, A.Gordeev

  4. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE . FRONT VIEW. R. Ruggiero, A.Gordeev

  5. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. SIDE VIEW R. Ruggiero, A.Gordeev

  6. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. SIDE VIEW 4 SNEW SUPPORT ELEMENTS INSTALLED: 2 ON THE BOTTOM AND 2 ON THE TOP R. Ruggiero, A.Gordeev

  7. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. NEW SUPPORT ELEMENT DETAIL 4 SNEW SUPPORT ELEMENTS INSTALLED: R. Ruggiero, A.Gordeev

  8. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. MESH R. Ruggiero, A.Gordeev

  9. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. MESH DETAIL R. Ruggiero, A.Gordeev

  10. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. MESH DETAIL R. Ruggiero, A.Gordeev

  11. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. SETTINGLOAD - STANDARD EATH GRAVITY R. Ruggiero, A.Gordeev

  12. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. DEFORMATION DUE TO NOT SYMMETRICAL ABSORBER STRUCTURE MODULE INCLINED TO ONE SIDE 1 mm = 0.03937” R. Ruggiero, A.Gordeev

  13. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. DEFORMATION DETAILS DEFORMATION ON DIFFERENT POINT OF ABSORBER R. Ruggiero, A.Gordeev

  14. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. DEFORMATION DETAILS R. Ruggiero, A.Gordeev

  15. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. EQUIVALENT STRESS 1 MPa = 145.038 p.s.i. R. Ruggiero, A.Gordeev

  16. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. EQUIVALENT STRESS. BOTTOM DETAILS R. Ruggiero, A.Gordeev

  17. sFHENIX HADRON CALORIMETER 90 degree Support Structure AnalysesANSYS MODULE. EQUIVALENT STRESS. DETAILS MAX STRESS LOCATED ON THE CALORIMETER BOTTOM ABSORBER PLATE SEPARATOR R. Ruggiero, A.Gordeev