270 likes | 376 Views
Explore the latest features and tools in EMR-Link to streamline lab operations. Learn about auto-splitting, new products, maintenance tips, radiology orders, and more. Improve clinic efficiency!
E N D
Housekeeping • Shrinking the GTM session • Being muted. • Your Audio Pin • Raising hands. • We’ll have breaks for questions. • Use “Chat” to queue up questions.
What We’ll Cover Today • What’s new with orders? • Auto-splitting • Courtesy copies • Billing interface • EMR-Link 2.0 (well, it’s not so new any longer) • What’s new with results? • Always copy this user….. • Send results to my HIE too…. • New products • PDF download • HIE Connect • Adding a second lab (and the three possible levels) • Adding radiology orders • Maintenance tips • When your lab changes an order code • Where to find help
The Whole Picture Clinic’s EMR-LINK Account Lab Lab compendiums • Point-of-care ABN Validation(Uses lab’s ABN rules) • Rules-based routing (insurance and location) • Clinic specific mappingof EMR-to-Lab data • Order Entry Questions • Requisition printing • ABN printing • Label printing Lab 2 Lab 1 Clinic’s mapping tables Requisition Completion 4 5 6 • HL7 compliant ORM • Complete order information to lab’s requirements HL7 Order Req 3 Routing Rules (choose the lab) Label 7 Lab Requisitioning Database EMR-Link Connector • Manifest Reports • Future Orders • Billing interface back to PM (future) 2 2 • Secure HTTPSdownloads • Auto-Completion • Provider desktop notification 1 3 8 EMR-LinkConnector Lab Result Manager Your Code EMR Order Codes Meds Electronic (HL7) Result LIS LinkLogic Radiology Services Clinic’s EMR
The Billing Interface Clinic’s EMR-LINK Account Lab Lab compendiums • Point-of-care ABN Validation(Uses lab’s ABN rules) • Rules-based routing (insurance and location) • Clinic specific mappingof EMR-to-Lab data • Order Entry Questions • Requisition printing • ABN printing • Label printing Lab 2 Lab 1 Clinic’s mapping tables Requisition Completion 2 • HL7 compliant ORM • Complete order information to lab’s requirements HL7 Order 1 Req Routing Rules (choose the lab) Label Lab Requisitioning Database EMR-Link Connector • Manifest Reports • Future Orders • Billing interface back to PM (future) PMIS 3 4 • Auto-Completion • Provider desktop notification EMR-LinkConnector Lab Result Manager Your Code EMR Order Codes Meds Electronic (HL7) Result LIS LinkLogic Radiology Services Clinic’s EMR
Consolidation For The Practice EMR-LINK Clinic’s mapping tables Order Completion Electronic (HL7) Order Lab Lab Routing Rules (choose the lab) Lab Orders Database EMR-Link Connector Lab • Secure HTTPSdownloads Lab Result Manager Your EMR Order Codes EMR-LinkConnector Meds Electronic (HL7) Results LinkLogic Radiology Services Clinic’s EMR
EMR-Link: Extensible Lab and EMR Connectivity • Labs with Bi- • Directional Integration • LabCorp • Quest • Bio-Reference • CPL (Sonic) • Mullins • Providence • PAML • PeaceHealth • Mercy Medical • Cortland EMR-Link Reference Labs EMR Clinic 1 HospitalLabs EMR Clinic 2 ImagingDepts EMR Clinic 3 Repositories(HIE or public)
EMR-to-Hospital Integration Practice Hospital EMR-Link Orders hospital services Orders PACS Lab ECG • Full text report Results review • Structured results Engine • URL link to image LinkLogic • Link to reporting system • Lab results • ECG reports/images • Radiology results/images • Practice Benefits • Order reconciliation (auto-completion) • Guaranteed chart matching • Link to images (radiology) • Hospital Benefits • Competitive Outreach Services • Increase Referrals to Departmental Services. • Clean orders (decreases write-offs)
Radiology Workflow Improvements • Pre-auth? • Scheduling? • Clinical lists Clinic Imaging • AOE questions • Minimize data entry Order Completion • Req’d insurance • Verified ABN • No data entry • Easy to order • ABN validated Physician Ordering RIS PACS Physician Review • Desktop notification • Updates the order status EMR Chart Matching • Results match to charts • Contains link to the image study
PDF Result Interfaces • The lab report you already know now includes a link that references the PDF • Enhanced view can include color, graphics, etc. Ideal for specialty labs • You can add multiple PDF storage locations as needed. E.g., if you fill up one disk you can leave the current PDF files there and start a new data store elsewhere. • Easy to install and configure. It only takes a few minutes more than a standard results kit. • PDF storage is at the clinic so you have ownership of the data • Works with all supported EMR releases except 5.6.
PDF Results Flow Clinic’s EMR-LINK Account Lab Lab compendiums • Point-of-care ABN Validation(Uses lab’s ABN rules) • Rules-based routing (insurance and location) • Clinic specific mappingof EMR-to-Lab data • Order Entry Questions • Requisition printing • ABN printing • Label printing Lab 2 Lab 1 Clinic’s mapping tables Requisition Completion • HL7 compliant ORM • Complete order information to lab’s requirements HL7 Order Routing Rules (choose the lab) Lab Requisitioning Database PDF File Store Link to PDF 4 2 Your EMR Order Codes EMR-LinkConnector Lab Result Manager Electronic (HL7) Result With PDF Meds LIS LinkLogic 3 1 Radiology Services Clinic’s EMR
Health Information Exchanges Health information exchange (HIE) is defined as the mobilization of healthcare information electronically across organizations within a region, community or hospital system.
EMR-Link: Extensible Lab and EMR Connectivity • Labs with Bi- • Directional Integration • LabCorp • Quest • Bio-Reference • CPL (Sonic) • Mullins • Providence • PAML • PeaceHealth • Mercy Medical • Cortland EMR-Link Reference Labs EMR Clinic 1 HospitalLabs EMR Clinic 2 ImagingDepts EMR Clinic 3 Repositories(HIE or public)
Implementation Times Improve From 120 hours … to 16 hours • Alliance of Chicago deploys EMRs at community health centers across the US • They’ve standardized on Ignis for all lab and imaging integration. They’ve seen improvements here……..
Automating The Setup: The Orders Builder Lab Utilization Reports Orders Builder EMR Clinical Kits EMR EMR Orders Builder • Builds your order categories(or maps the ones you already have) • Builds your custom order lists
The Lab Results Builder • Builds your EMR flow-sheet • Builds your cross reference (xref) from lab codes to EMR flow-sheet observation terms(or evaluates the one you have already)
In Closing • Provider and practice workflow is job 1 • We automate setup • We automate maintenance • We’ll keep you up to date (monthly release notes) • We give you tools for your job (ROI worksheet) • Contact us any timewww.emr-link.com
Results Only Dataflow Lab • Uniform and Secure Download Mechanism for the Clinic • Download method for one lab or many labs • Uniform Distribution Mechanism for Labs • Establishes EMR-Link framework for adding Lab Orders. Paper Lab Order Clinic’s EMRLINK Account • Queues results for the clinic • Responds to HTTPS requests for downloads. • Secure HTTPSdownloads EMR-LinkConnector Result Manager Lab Order Codes Meds Electronic (HL7) Result LinkLogic Radiology LIS Services Clinic’s EMR Lab Results
Comparing Lab Orders…. Centricity EMR 9.2 And EMR-Link
The Benefits of Centricity 9.2HL7 ORM and assisted order completion. Lab ORM complies with the HL7 ORM orders message needed by the labs. Patient ID in the order guarantees a match to the patient’s chart when the result is returned. Narrows the choices of orders for manual “complete” • HL7 compliant ORM • Patient ID • Provider ID Lab Orders Lab Order Codes Meds LinkLogic Radiology Lab Results LIS Services Clinic’s EMR
EMR-Link adds the following to 9.2 Lab • Billing decisions are made. • Test specific (AOE) Order Entry Questions • Requisition printing • ABN printing • Label printing • Point-of-care ABN Validation(Uses lab’s ABN rules) • Rules-based routing (insurance and location) • Clinic specific mappingof EMR-to-Lab data 1 2 4 Clinic’s mapping tables Order completion 3 Lab Orders • HL7 compliant ORM • Patient ID • Provider ID Orders database 5 • Manifest Reports • Future Orders • Billing messages sent to clinic’s PM. Lab Order Codes Meds • Auto-Completion • Dr. Desktop Notification LinkLogic Radiology Lab Results LIS Services 6 Clinic’s EMR
The Difference…… with EMR-Link you get 9.2 ORM support and. • Point of care ABN validation. EMR-Link informs the provider at the point of care that a lab test is medically necessary based on CRM (Medicare)’s ABN rules. • Rules based routing. EMR-Link routes your lab tests to the appropriate lab service provider, based on the patient’s insurance and your location of care preferences. • Support for UPIN or NPI. The provider’s UPIN or NPI number is inserted into the order. Also, once the lab is chosen, EMR-Link inserts the correct order codes for that lab, the correct insurance codes, and the account number for that lab. • Requisition completion --- with minimal manual entry of order data. • No manual entry of data by your nurse or phlebotomist. • Insurance rules decide if billing is to the 3rd party (insurance company), client (bill to the clinic), or to the patient. • Required test specific AOE (ask at order entry) questions are asked • Requisitions to the lab’s specifications are printed • Labels are printed for specimen containers • ABNs, when needed, are printed. • Manifest Reporting: The EMR-Link lab orders database provides • Downloadable manifest reporting includes: patient, test ordered, chosen lab, billing type chosen, insurance, Patient Service Center orders, ….etc. • Future orders are stored here until the patient returns for the specimen collection, triggering the “Order Completion” process. • HL7 billing messages are returned to the practices PM based on insurance or lab chosen. • Auto-Completion of Orders. Returned lab results are processed with the initial lab orders information. • EMR test IDs are inserted into the ORU result, enabling Centricity EMR’s “auto-completion” machinery. Upon signing of the result, the specific tests will auto-complete. • The ordering provider’s UPIN (or NPI) is converted to their EMR login. This ensures desktop notification to the ordering provider.
Data Flow for PDF Downloads Centricity EMR Lab EMR-LINK EMR-Link Connector ABN Validation EMR-Link Database Electronic (HL7) Order ORU Message Provider’s Desktop LinkLogic MDM Message With PDF Reference • ResultManager: • Receive lab result and encoded PDF • Insert original EMR order ID • Insert ordering provider • Send PDF to Clinic file store • Send ORU to EMR • Send MDM to EMR PDF File HTTPS Patient’s Chart Electronic (HL7) Result With embedded PDF Clinic’s PDF File store