Online DAQ System: From Detector to Tape. T. Yasuda Fermilab. Overview Hardware Control System Primary/Secondary Data Path DAQ Applications DAQ in action Conclusions. Overview. The DØ DAQ system is divided into two components: Trigger system Level 1 hardware trigger components

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about ' Online DAQ System: From Detector to Tape' - kyra-cline


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
Online daq system from detector to tape

Online DAQ System: From Detector to Tape

T. Yasuda

Fermilab

NIU Workshop


Online daq system from detector to tape

  • Overview

  • Hardware

  • Control System

  • Primary/Secondary Data Path

  • DAQ Applications

  • DAQ in action

  • Conclusions

NIU Workshop


Overview
Overview

  • The DØ DAQ system is divided into two components:

  • Trigger system

    • Level 1 hardware trigger components

    • Level 2 specialized processors

    • Level 3 crate readout and software trigger components

  • Online or Host system

    • Detector controls

    • Data Logging

    • Monitoring

    • Control room applications

  • NIU Workshop


    Overview1
    Overview

    • DAQ Architecture

      • Event data rate and operational redundancy achieved by a high degree of parallelism

        • Level 3

        • Host

      • Capability for multi-user, multi-stream operation

        • With central resource configuration manager

      • Network-centric Host design

    NIU Workshop


    Daq components
    DAQ Components

    Detector

    Trigger and Readout

    Controls

    NT Level 3

    Control

    Room

    PCs

    Linux

    PCs

    UNIX

    Servers

    FCC

    NIU Workshop


    Hardware description
    Hardware Description

    • 3 Compaq/Digital Alpha Servers

      • d0ola: Alpha Server 4000, 1 processor, 466MHz, 500 MB memory

      • d0olb: Alpha Server 4000, 2 processors, 600 MHz, 500 MB memory

      • d0olc: Spec out by Aug 3. Probably Alpha Server ES40, 4 processors, 667 MHz

      • Clustered / redundant

      • 500 GB shared RAID disks for online apps and database (Mirrored)

      • 500+ GB local ‘data buffer’ disks, fiber channel based (40M/sec)

    NIU Workshop


    Hardware description1
    Hardware Description

    • Linux/NT nodes

      • Buying 6 nodes with dual PIII, 600 MHz, 500MB memory, 2 graphics cards

      • 3 Linux nodes and 3 NT nodes exist

      • Will run Vmware on Linux nodes

    • Control system embedded 68Ks and PowerPCs (VxWorks)

    • Network

      • Cisco 6509 GB Ethernet switch for all FCH nodes

      • Satellite 100 MB switches in MCH

      • GB fiber to FCC

    • Security

      • Access control filter to online machines

      • Kerberos authenticated ssh session only

    NIU Workshop


    Control monitoring

    Hardware

    Database

    Control & Monitoring

    1553

    Detector

    Vertical Interconnect

    Controls

    Trigger and Readout

    Controls Crate

    Readout Crate

    Ethernet

    EPICS Clients:

    Low Voltage

    High Voltage

    Rack Monitor

    1553 Devices

    SMT Monitor

    FT Monitor

    etc

    EPICS DB Generator

    ORACLE

    Control Room PCs

    UNIX Servers

    NIU Workshop


    Control system
    Control System

    • Built upon EPICS control system

      • A ‘standard’ toolkit upon which we’ve built DØ extensions

      • Lots of user-community supplied tools

    • ORACLE Hardware Database

      • Extract EPICS db from ORACLE

      • Web-based and batch interfaces

    • Hardware Control

      • Low Voltage, High Voltage, etc dedicated GUI applications

    • Downloading

      • Registers, Pedestals, etc

    • Significant Event (alarm) System

    • Interface to Accelerator and Cryogenics controls systems

    NIU Workshop


    Status of control system
    Status of Control System

    • Calorimeter

      • Preamp PS, BLS PS, ADC PS control exist

      • Pulser control (in progress)

    • SMT

      • EIPCS records for Sequencer, Sequencer control, VRB, VRBC, Emulator (in progress) exist and used in the test stands

    • Muon

      • Tested communication using 1553 for PDT, MDT, SRC cards

    • FPD

      • Used RM support to control motors

    NIU Workshop


    Status of control system1
    Status of Control System

    • Luminosity

      • Scalers and FE processing results communicated to Accelerator via ACNET

    • Cryo

      • Communicated with DMAX system

    • Common Tools

      • generic 1553 support

      • generic VME support

      • HV used in SMT, Muon, Lum

        • V1 running for months, V2 work starting

      • Diagnostic support for busses

      • Standard operator interface (GUI)

    NIU Workshop


    Hardware database
    Hardware Database

    • Describes Control aspects of electronics

    • Based on ORACLE

      • 2 instances of the database ( dev, user testing)

    • Web based interface for entering, modifying, deleting records

    • Python script for batch entries exists

    • Calorimeter records in the database

    NIU Workshop


    Hardware database1
    Hardware Database

    NIU Workshop


    Significant event alarm system
    Significant Event (Alarm) System

    • System to detect alarm conditions and state changes in the DAQ system

      • Server with DAQ components as clients

      • COOR sends alarm and run control messages

      • CR, DL, DD send alarm messages

      • Version 1 Display exists

      • Working on version 2 Display (Summer student)

      • Need to integrate EPICS alarms into the system (Fall 2000)

        • on IOC EPICS alarms -> ITC client

        • ITC client sends alarms to Server on host

        • EPICS Alarm Handler can be used for now

    NIU Workshop


    Significant event system

    Front-End

    Significant Event System

    Filter

    F

    SE Message

    Process

    Filtered Message

    Periodic

    Heartbeat

    Heartbeat

    Significant Event

    Server

    F

    F

    F

    F

    Display

    Archiver

    F

    HV Control

    Fault Watcher

    Run Control

    (COOR)

    Run

    Suspend

    NIU Workshop


    Configuration run control

    Disk

    Configuration & Run Control

    1553

    Detector

    Vertical Interconnect

    Controls

    Trigger and Readout

    Controls Crate

    Readout Crate

    L1, L2, TCC

    Data Cable

    L3 VRC

    L3 Supervisor

    Data Cable

    Control Room PCs

    L3 Filter

    Run Control

    Client

    NT Level 3

    Ethernet

    Collector / Router

    COOR

    Data Logger

    Comics

    Data Distributor

    EXAMINE

    DSM

    RIP

    UNIX Servers

    Linux PCs

    Ethernet

    FCC

    NIU Workshop


    Software description
    Software Description

    • Configuration Management and Run Control

      • Coordination (COOR)

      • User interface (TAKER)

      • Download manager (COMICS)

    • Primary event path

      • DAQ State Manager (DSM)

      • Collector / Router

      • Data Logger

      • Event metadata manager (SAM)

      • Event data manager (enstore)

    • Secondary event path

      • Secondary DAQ Supervisor

      • Data Merger

    NIU Workshop


    Software description1
    Software Description

    • Event monitoring

      • Data Distributor

      • Analysis applications (EXAMINE)

    • DAQ Monitoring

      • Client/Server access to DAQ flow statistics, trigger rates, etc

    • Detector Monitoring

      • Front End active & parasitic monitors

    • Calibration

      • Client/Server interface to database

    • Infrastructure

      • Databases (ORACLE)

      • Task-to-task communication (ITC)

    NIU Workshop


    Secondary daq data flow

    EPICS

    CA Server

    Detector DAQ

    Shared

    Data

    EPICS

    CA Client

    Data Merge

    Collector / Router

    Collector / Router

    Monitor GUI

    Data Logger

    Data

    Distributor

    Data

    Logger

    EXAMINE

    Examine

    GUI

    Disk

    Disk

    Examine

    RIP

    RIP

    Secondary DAQ Data Flow

    Detector

    1553Bus

    VMEBus

    Controls/Readout

    Crates

    CA Link

    ITC

    Control Room PCs

    Linux PCs

    UNIX Server

    UNIX Server

    FCC

    NIU Workshop


    Secondary daq system
    Secondary DAQ System

    • Alternative data path

    • Mainly used for monitoring and calibration

    • Takes advantage of powerful front-end processors

    • Uses the same data path as the primary path after Data Merger

    NIU Workshop


    Daq monitor
    DAQ Monitor

    • Monitors the status of DAQ subsystems (L1/2, CR, DL, DD)

    • Collects statistics information from the subsystems

    • C++ itc Server with python Display clients

    NIU Workshop


    Daq monitor1
    DAQ Monitor

    NIU Workshop


    Event monitoring examine
    Event Monitoring:EXAMINE

    • Samples and reconstructs event based on Stream IDs and trigger IDs

    • Clients of Distributor

      • Network and file event transfer modes work

      • Calorimeter EXAMINE

        • used for preamp testing

      • CFT EXAMINE

        • Getting ready for raw data unpacking

        • MC packed data?

      • SMT EXAMINE

        • used for SiDet data

      • Muon EXAMINE

        • used for commissioning

    NIU Workshop


    Event monitoring examine1

    Disk

    Event Monitoring: EXAMINE

    Detector

    Trigger and Readout

    Readout Crate

    L1, L2, TCC

    Data Cable

    L3 VRC

    L3 Supervisor

    Data Cable

    L3 Filter

    NT Level 3

    Ethernet

    ROOT Client

    Collector / Router

    EXAMINE

    Data Logger

    Data Distributor

    Express Line

    ROOT Client

    Control Room PCs

    UNIX Servers

    Linux PCs

    NIU Workshop


    Event monitoring examine2
    Event Monitoring:EXAMINE

    • Need:

      • L3 EXAMINE

      • Vertex EXAMINE

      • Preshower EXAMINE

    • Planned improvements

      • Histoscope -> Root after NIU workshop

      • on-the-fly histogram

      • e-browser

      • Framework improvement

        • name server for accessing only the histograms

    NIU Workshop


    Online event display
    Online Event Display

    NIU Workshop


    Online calibration
    Online Calibration

    • Perform electronics calibration of sub-detectors and insert results to ORACLE database

    • COOR controlled via Taker

    • Common server and database interface for all sub-detectors

    • Calibration results transmitted as special event messages through DAQ paths

    • Current status

      • Successfully ran SMT calibration at 1% test stand and NW test stand

    NIU Workshop


    Calibration manager
    Calibration Manager

    Taker

    Configure

    Calib Manager

    Display

    Request start run

    Start run,

    End run

    COOR

    Calibration

    Manager

    Comparison

    Results

    End calib.

    Request

    download

    Pedestals

    Gains

    End run

    Validator

    COMICS

    Database

    Interface

    Pedestals

    Gains

    Start run

    Download

    Database

    Access

    Crates

    Data

    Calib. Data

    Processor

    Calibration

    Database

    NIU Workshop


    Online daq in action
    Online DAQ in Action

    • Electronics/DAQ Commissioning

      • 2 VRB crates with 10 cards each, synchronized with SCL from TFW to L3

      • L1 muon crate

      • 1 Muon Scint crate with 2 MRCs

      • 1 Muon PDT crate with 1 MRC

      • 1 Calorimeter crate

      • Combinations of 2 systems done

        • but not with MCH2+MCH3

      • 2 simultaneous runs done

        • 3 simultaneous runs require one more L3 node or script runner

    NIU Workshop


    Online daq in action1
    Online DAQ in Action

    • SMT Test Stands

      • 1% and NW test stands

        • 1 HDI, 1 Sequencer, 1 VRB, 1 VRBC, 1 VBD

        • Download done with COMICS and database

      • 10% test stand

        • 3 HDIs, a few Interface Boards, a few Sequencers, a few VRBs, 1 VRBC, 1 1553 controler, 1 VBD + L3

        • Download done by spread sheet for now

      • Databases (Electronics) exist for all three stands

      • Calibration run performed at 1% and NW test stands

    NIU Workshop


    Online daq in action2
    Online DAQ in Action

    • Commissioning Run

      • Two detectors installed for the upcoming Commissioning Run

        • Run I Luminosity scintillation counters

        • Forward Proton Detector

      • Both detectors will be read out using the Run II Online system.

      • Data will be transferred to and from the Accelerator Controls System via the EPICS/ACNET Gateway.

    NIU Workshop


    Conclusions
    Conclusions

    • All of the DAQ components exist and function.

    • Improvements are implemented daily following user suggestions.

    • We have been intimately involved in daily commissioning activities for the past few months.

    • Bring in your sub-detectors!!

    NIU Workshop