Outcomes of surgery for posterior polar cataract using torsional handpiece

Outcomes of surgery for posterior polar cataract using torsional handpiece. Dr. Aysel Pelit, Dr. Yonca A. Akova Baskent University, Faculty of Medicine, Adana, Turkey No author has a financial or proprietary interest in any material or method mentioned. Purpose.

knoton
Download Presentation

Outcomes of surgery for posterior polar cataract using torsional handpiece

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Outcomes of surgery for posterior polar cataract using torsional handpiece Dr. Aysel Pelit, Dr. Yonca A. Akova Baskent University, Faculty of Medicine, Adana, Turkey No author has a financial or proprietary interest in any material or method mentioned

  2. Purpose • The aims of this study wereto report outcomes of surgery for posterior polar cataract using the OZil torsional handpiece.

  3. Method-I • Medical records of 26 eyes of 21 consecutive patients with posterior polar cataract who had cataract surgery using the OZil torsional handpiece were evaluated • The cataract surgeries were performed by the same surgeon (AP) • All surgeries were carried out under peribulbar anaesthesia

  4. Method-II • Continuous curvilinear capsulorhexis was performed under an ophthalmic viscosurgical device • Hydrodissection was avoided in order to prevent posterior capsule rupture • All patients underwent hydrodelineation • For soft nucleus, the chip and flip technique was used. The parameter used were 100 mmHg and 20% torsional amplitude

  5. Method-III • For harder nucleus (grade II-III), the stop and chop technique was used. The parameters used for trenching were 50-60 mm Hg vacuum and 80%-90% torsional amplitude. Emulsification was done at the 60%-70% torsional amplitude at an increased vacuum pressure of 100 mmHg. • Throughout the procedure the aspiration flow rate was 16-18 ml/min at the bottle height of 50-60 cm

  6. Method-IV • In all cases the epinucleus was aspirated and pulled towards the centre without crossing the central area • All cortex had been brought to the centre it was aspirated together with the central area • Usually, the plaque came out with the aspiration, but in some there was central posterior capsule rupture

  7. Results • Of the 26 eyes, 24 (92.3%) had small to medium posterior polar opacity. Two eyes had large opacity. • Posterior capsule rupture occurred in 4 (15.3%) eyes. The mean visual acuity improved significantly after surgery (p<0.001). • The postoperative visual acuity was worse than 20/20 in 5 eyes. The cause of the low acuity was amblyopia.

  8. Conclusion • Posterior polar cataract can be safely extracted using the OZil torsional handpiece. • Phacoemulsification using the OZil torsional handpiece leads to good visual outcome.