An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Chapter 15: Using Therapeutic Modalities © 2011 McGraw-Hill Higher Education. All rights reserved

  2. Therapeutic modalities can be an effective adjunct to various techniques of therapeutic exercise • Knowledge of the healing process is critical • A variety of modalities can be utilized by athletic trainers including cryotherapy, electrical stimulation, ultrasound, massage, traction, diathermy, lasers and magnets © 2011 McGraw-Hill Higher Education. All rights reserved

  3. Classification of Therapeutic Modalities • Electromagnetic • Includes cryotherapy, thermotherapy, electrical stimulating currents, diathermy and lasers • Rely on electromagnetic energy, which travels at the speed of light • Energy travels in a straight line • The energy can be absorbed, refracted, reflected or transmitted © 2011 McGraw-Hill Higher Education. All rights reserved

  4. Acoustic • Ultrasound utilizes acoustic energy • High frequency sound waves • Relies on molecular collisions for energy transfer • Vibration of tissue produces heat and impacts cell membrane permeability • Mechanical • Traction, intermittent compression, massage • Involves mechanically stretching, compressing and manipulating soft tissue and joint structures © 2011 McGraw-Hill Higher Education. All rights reserved

  5. Electromagnetic Modalities © 2011 McGraw-Hill Higher Education. All rights reserved

  6. Thermotherapy • Physiological Effects of Heat • Dependent on type of heat energy applied, intensity of energy, duration of exposure and tissue response • Heat must be absorbed to increase molecular activity • Desired effects • Increase collagen extensibility; decreasing joint stiffness; reducing pain; relieving muscle spasm; reduction of edema and swelling; increasing blood flow © 2011 McGraw-Hill Higher Education. All rights reserved

  7. Extensibility of collagen • Permits increases in extensibility through stretching • Pain relief • Activates gate control mechanism • Muscle spasm • Increased blood flow reduces ischemia • Assistance w/ healing process • Raises tissue temperature, increases metabolism resulting in reduction of oxygen tension, lowering pH, increasing capillary permeability and releasing bradykinins and histamine resulting in vasodilation • Parasympathetic impulses stimulated by heat are also believed to be a reason for vasodilation © 2011 McGraw-Hill Higher Education. All rights reserved

  8. Superficial Heat • Form of electromagnetic energy (infrared region of spectrum) • Increases subcutaneous temperature, indirectly spreading to deeper tissue • Muscle temperature increases through reflexive effect of circulation through conduction • Moist heat versus dry heat © 2011 McGraw-Hill Higher Education. All rights reserved

  9. Transmission of Thermal Energy • Conduction • Heat is transferred from a warmer object to a cooler one • Dependent on temperature and exposure time • Temperatures of 116.6o F will cause tissue damage and temperatures of 113o F should not be in contact w/ the skin longer than 30 minutes • Examples include moist hot packs, paraffin, ice packs and cold packs © 2011 McGraw-Hill Higher Education. All rights reserved

  10. Convection • Transfer of heat through movement of fluids or gases • Temperature, speed of movement, and conductivity of part impact heating • Whirlpools • Radiation • Heating is transferred from one object through space to another object • Shortwave diathermy, infrared heating and ultraviolet therapy • Conversion • Generation of heat from another object (sound, electricity or chemical agents) © 2011 McGraw-Hill Higher Education. All rights reserved

  11. Hydrocollator Packs • Equipment • Silicate gel pads submersed in 160-170o F water • Maintains heat for 20-30 minutes; must use 6 layers of terry cloth to protect skin Figure 15-1 © 2011 McGraw-Hill Higher Education. All rights reserved

  12. Indications • Used for general muscle relaxation and reduction of pain-spasm-ischemia-hypoxia-pain cycle • Limitation - unable to heat deeper tissues effectively • Application • Pack removed from water; covered w/ 6 layers of toweling which are removed as cooling occurs; area treated for 15-20 minutes • Athlete must be comfortable and should not lay on pack © 2011 McGraw-Hill Higher Education. All rights reserved

  13. Whirlpool Bath • Equipment • Varying sizes used to treat a variety of body parts • Tank w/ turbine that regulates flow • Agitation (amount of movement) is controlled by air emitted • Indications • Combination of massage and water immersion • Provides conduction and convection • Swelling, muscle spasm and pain • Application • Temperature is set according to treatment goals • Athlete should be set up to be reached by agitator (8-12” from agitator) • Do not place directly on injured site • Maximum treatment time for acute injuries should not exceed 20 minutes © 2011 McGraw-Hill Higher Education. All rights reserved

  14. Special Considerations Must be careful with full-body immersion Proper maintenance is necessary to avoid infection As volume of body part immersion increases, temperature should decrease Safety is a major concern Electrical outlets Athlete should not turn whirlpool on or off Contraindicated for acute injuries due to gravity dependent position Figure 15-2 © 2011 McGraw-Hill Higher Education. All rights reserved

  15. Paraffin Bath • Equipment • A paraffin wax and mineral oil combination, heated to 126-130o F, plastic bags, paper towels and towels • Indications • Useful in treating chronic injuries • Effective for angular areas of body such as hands, wrists, elbows, ankles and feet • Application • Body part is cleaned and dried • Dip and wrap technique • Hand dipped 6-12 times, wrapped in a plastic bag and then draped w/ a towel to maintain heat for 30 minutes • Soak technique • Body part remains in wax 20-30 minutes w/out moving it © 2011 McGraw-Hill Higher Education. All rights reserved

  16. Fluidotherapy • Equipment • Unit which contains cellulose particles through which warm air is circulated • Allows for high heating (higher than water and paraffin) • Indications • Used to treat distal extremities in effort to decrease pain, increase ROM and decrease swelling and spasm • Application • Temperature ranges from 100-113o F • Particle agitation should be controlled for comfort • Patient should be comfortable • Treatment time = 15-20 minutes • Exercise can be performed while in cabinet © 2011 McGraw-Hill Higher Education. All rights reserved

  17. Figure 15-3 Figure 15-4 © 2011 McGraw-Hill Higher Education. All rights reserved

  18. Special Consideration w/ Superficial Heat • Important contraindications • Never apply heat when there is loss of sensation • Never apply heat immediately after injury • Never apply heat when there is decreased arterial circulation • Never apply heat directly to eyes or the genitals • Never heat the abdomen during pregnancy • Never apply heat to a body part that exhibits signs of acute inflammation © 2010 McGraw-Hill Higher Education. All rights reserved © 2011 McGraw-Hill Higher Education. All rights reserved

  19. Cryotherapy • Used in first aid treatment of trauma to the musculoskeletal system • When applied intermittently w/ compression, rest and elevation it reduces many adverse conditions related to inflammation and the reactive phase of an acute injury • RICE (rest, ice compression, elevation) may be used for the initial days of and injury and continue up to 2 weeks after injury © 2011 McGraw-Hill Higher Education. All rights reserved

  20. Physiological Effects of Cold • Type of electromagnetic energy (infrared radiation) • Relies on conduction -- degree of cooling depends on the medium, length of exposure and conductivity • At a temperature of 38.3oF, muscle temperature can be reduced as deep as 4cm • Tissue w/ a high water content is an excellent conductor • Most common means of cold therapy are ice packs and ice immersion • Wet ice is a more effective coolant due to the energy required to melt ice © 2011 McGraw-Hill Higher Education. All rights reserved

  21. Vasoconstriction • Reflex action of smooth muscle due to sympathetic nervous system and adrenal medulla • Hunting response • Intermittent period of vasodilation will occur if cooling continues for >20 minutes • Blood viscosity will also increase with extended cooling • Decreases extent of hypoxic injury to cells • Decreases cell metabolic rate and the need for oxygen through circulation, resulting in less tissue damage • Decreased metabolic rate and vasoconstriction decreases swelling associated w/ inflammatory response © 2011 McGraw-Hill Higher Education. All rights reserved

  22. Decreases muscle spasm • Muscle becomes more amenable to stretch as a result of decreased GTO and muscle spindle activity • Decreases free nerve ending and peripheral nerve excitability • Analgesia caused by raising nerve threshold • Cold is more penetrating than heat • Ability to decrease muscle fatigue and increase and maintain muscular contraction • Attributed to the decrease of local metabolic rates and tissue temperature © 2011 McGraw-Hill Higher Education. All rights reserved

  23. Ice Massage • Equipment • Foam cup with frozen water - creating a cylinder of ice (towel will be required to absorb water) • Indications • Used over small muscle areas (tendons, belly of muscle, bursa, trigger points) • Application • Ice is rubbed over skin in overlapping circles (10-15 cm diameters) for 5-10 minutes • Patient should experience sensations of cold, burning, aching, & numbness --when analgesia is reached athlete can engage in rehab activities • Special considerations • Keep in mind comfort of the athlete during treatment © 2011 McGraw-Hill Higher Education. All rights reserved

  24. Figure 15-5 © 2011 McGraw-Hill Higher Education. All rights reserved

  25. Cold or Ice Water Immersion • Equipment • Variety of basins or containers can be used, small whirlpool • Temperature should be 50-60 degrees F • Indications • Circumferential cooling of a body part • Application • Patient immerses body part in water and goes through four stages of cold response • Treatment may last 10-15 minutes • Once numb, body part can be removed from immersion and ROM exercise can be performed • As pain returns re-immersion should take place • Cycle can be repeated 3 times © 2011 McGraw-Hill Higher Education. All rights reserved

  26. Cold or Ice Water Immersion (continued) • Special Considerations • Cold treatment makes collagen brittle -- must be cautious with return to activity following icing • Be aware of allergic reactions and overcooling © 2011 McGraw-Hill Higher Education. All rights reserved

  27. Ice Packs (Bags) • Equipment • Wet ice (flaked ice in wet towel) • Crushed or chipped ice in self sealing bag • Not as efficient, but less messy • Useful for approximately 15-20 minutes • Towel should be placed between skin and pack • Chemical Cold packs • Gel pack • Liquid pack • Indications • Athlete experiences four stages of cooling and then proceeds with ROM exercises © 2011 McGraw-Hill Higher Education. All rights reserved

  28. Special Considerations • Avoid excessive cold exposure • With any indication of allergy or abnormal pain, treatment should be stopped • When using gel packs, a single layer of toweling should be used • Crushed or flaked ice can be directly applied to skin Figure 15-6 © 2011 McGraw-Hill Higher Education. All rights reserved

  29. Vapocoolant Sprays • Equipment • Fluori-methane - non-flammable substance that is released in fine spray from pressurized canister • Indications • Reduces muscle spasm, increases ROM, effective on trigger point • Application • For spasm and ROM • Hold can 12-18 inches from skin, treat entire length of muscle - covering an area 4 inches/second • Apply spray 2-3 times, while gradually applying a stretch © 2011 McGraw-Hill Higher Education. All rights reserved

  30. Vapocoolant Spray (continued) • Application • For trigger points • Locate trigger point • Position athlete in relaxed position; place muscle on stretch; apply spray in specific region and over the length of the muscle • Apply passive stretch while spraying • After first session, heat area and then repeat if necessary • When stretch is complete, have athlete move limb throughout ROM; but do not overload © 2011 McGraw-Hill Higher Education. All rights reserved

  31. Figure 15-7 © 2011 McGraw-Hill Higher Education. All rights reserved

  32. Cryokinetics • Technique that combines cryotherapy with exercise • Goal is to numb region to point of analgesia and work towards achieving normal ROM • Equipment • Treat area with ice pack, massage or immersion • Application • When analgesia is experienced, exercises should be performed (window will last 4-5 minutes) • As pain returns, process may be repeated • Sequence can be repeated 5 times • Exercises should be pain free • Changes in intensity should be limited by both healing and patient’s perception of pain © 2011 McGraw-Hill Higher Education. All rights reserved

  33. Special Considerations for Cryotherapy • Cooling for an hour at 15.8o - 30.2o F produces redness and edema that lasts for 24 hours post exposure • Immersion at 41oF increases limb fluid volume by 15% • Exposure for 90 minutes at 57.2o - 60.8o F can delay resolution of swelling up to one week • Some individuals are allergic to cold and react w/ hives and joint pain • Icing through a towel or bandage limits the reduction in temperature -- could limit effectiveness of treatment © 2011 McGraw-Hill Higher Education. All rights reserved

  34. Special medical conditions • Raynaud’s phenomenon • Paroxysmal cold hemoglobinuria • Application of ice (very rare) can cause nerve palsy • Motor nerves close to skin overexposed to cold (peroneal nerve at head of fibula) © 2011 McGraw-Hill Higher Education. All rights reserved

  35. Electrical Stimulating Currents • Physical Properties of Electricity • Electricity displays magnetic, chemical, mechanical, and thermal effects on tissue • Volume of current (ampere) • Rate of flow of 1 amp = 1 coulomb • Resistance = ohms • Force that current moves along = voltage • Electricity is applied to nerve tissue at certain intensities and duration to reach tissue excitability thresholds resulting in membrane depolarization • Target sensory, motor, and pain nerve fibers in an effort to produce specific physiological effects © 2011 McGraw-Hill Higher Education. All rights reserved

  36. Equipment • Three types of units • TENS - transcutaneous electrical nerve stimulators • NMES/EMS - neuromuscular electrical stimulators or electrical muscle stimulators • MENS/LIS - microcurrent electrical nerve stimulators or low-intensity stimulators • Generate 3 types of current • Monophasic • Direct current or galvanic current - flow in one direction only from (+) to (-) or vice versa • Used to produce muscle contraction, pain modulation, ion movement (determined by specific parameters) © 2011 McGraw-Hill Higher Education. All rights reserved

  37. Figure 15-8 © 2011 McGraw-Hill Higher Education. All rights reserved

  38. Biphasic • Alternating current where direction of flow reverses during each cycle • Useful in pain modulation and muscle contractions • Pulsatile • Pulsed currents usually contain three or more pulses grouped together • Generally interrupted for short periods of time and repeat themselves at regular intervals • Used in interferential and so-called Russian currents • Current Parameters • Waveforms • Different generators have differing abilities relative to the production of various waveforms • A graphical representation of shape, direction, amplitude and direction of current • Can be sine, square or triangular in shape © 2011 McGraw-Hill Higher Education. All rights reserved

  39. Figure 15-9 Figure 15-10 © 2011 McGraw-Hill Higher Education. All rights reserved

  40. Modulation • Ability of stim unit to change or alter the magnitude and duration of a waveform • May be continuous, interrupted or surged for both AC and DC currents • Intensity • Voltage output of stimulating unit • High and low voltage units • Duration (pulse width or pulse duration) • Refers to the length of time that current is flowing • Pre-set on most high voltage DC units • Frequency • Number of waveform cycles per second © 2011 McGraw-Hill Higher Education. All rights reserved

  41. Polarity • Direction of flow -- either positive or negative • Electrode Set-up • Use of moist electrodes fixed to the skin • Can include monopolar (active and dispersive pad) or bipolar set-up • Current generally felt under and between both pads unless monopolar set-up is used --then current is felt under the smaller active pad © 2011 McGraw-Hill Higher Education. All rights reserved

  42. Indications • Pain Modulation • Gate Control • Intensity should produce tingling w/out a muscular contraction • High frequency and pulse duration • Descending Pain Control • High current intensity approaching noxious • Pulse duration of 10 msec; frequency should be 80 pps • Opiate Pain Control Theory • Point stimulator should be used with current intensity set as tolerable • Pulse duration should be at maximum; w/ a frequency of 1-5 pps © 2011 McGraw-Hill Higher Education. All rights reserved

  43. Muscle Contraction • Quality of contraction will change according to current parameters • Increased frequency results in increased tension (50pps results in tetany) • Increased intensity spreads current over larger area • Increased current duration causes more motor unit activation • Muscle pump • Used to stimulate circulation • High-volt, DC stimulator; 20-40 pps; surge mode (on/off 5 seconds each; elevation w/ active contraction • Treatment time 20-30 minutes © 2011 McGraw-Hill Higher Education. All rights reserved

  44. Muscle strengthening • High frequency AC current; 50-60 pps; 10:50 seconds on/off ratio; 10 repetitions 3x per week; perform with active contractions • Retardation of atrophy • High frequency AC current 30-60 pps; w/ voluntary muscle contraction encouraged; 15-20 minutes • Muscle re-education • Level of comfortable contraction -- 30-50 pps; w/ either interrupted or surge current • Athlete should attempt to contract muscle along w/ stim • Treatment time 15-20 minutes and repeated multiple times over the course of a week © 2011 McGraw-Hill Higher Education. All rights reserved

  45. Iontophoresis • Introduction of ions into body tissue via direct electrical current • Equipment • Iontophoresis generator which produces a continuous monophasic current • Indications • Used to treat musculoskeletal inflammatory conditions, analgesic effects, scar modification, wound healing, calcium deposits, hyperhidrosis • Medication • Dexamethasone and hydrocortisone are two commonly used © 2011 McGraw-Hill Higher Education. All rights reserved

  46. Application • Reusable or commercially produced electrodes • Three application techniques • Active pad over medication saturate gauze • Body part and active electrode submerged in tub of ion solution • Special active electrode with medication reservoir • Utilize large dispersive pad • Movement of positively and negatively charged ions relative to electrode charges (poles) • Treatment last 10-20 minutes depending on current intensity and ion concentrations in solution • Requires use of low voltage direct current on continuous mode w/ a long pulse duration (allows for migration of ions) • Must be careful to avoid chemical burns and certain to utilize appropriate medications for specific conditions © 2011 McGraw-Hill Higher Education. All rights reserved

  47. Interferential Currents • Equipment • Uses 2 separate generators, emitting current at slightly different frequencies • Quad polar pad placement is used, creating interference pattern • Creates a broader area of stimulation • Indications • Pain control (including joints), swelling, neuritis, retardation of callus formation following fracture & restricted mobility • Application • Pads must be placed to ensure that current is centered over painful area • Similar treatment parameters can be used © 2011 McGraw-Hill Higher Education. All rights reserved

  48. Low Intensity Stimulators • Equipment • Micro-current electrical nerve stimulator • Operates at low frequencies and intensities (sub-sensory) • Indications • Used to stimulate healing of soft tissue and bone • Modulate pain, promote wound healing, promote non-union fracture healing, tendon and ligament healing • Based on theory, little research support • Application • Utilizes same electrical currents as previously described • Using large dispersive pad maintains current density at thresholds which will not result in sensory nerve depolarization © 2011 McGraw-Hill Higher Education. All rights reserved

  49. Shortwave Diathermy • Physiological Effects • Generates deep tissue heating • Higher water content facilitates healing • Dependent on thickness of subcutaneous tissue • Heats tissue by introducing high frequency electrical current • Heats tissue by introducing high frequency electrical current © 2011 McGraw-Hill Higher Education. All rights reserved

  50. Pulsed diathermy is relatively new • Not continuous – reduces likelihood of significant tissue temperature increase • Utilizes drum electrode • Produces both thermal and non-thermal effects • Equipment • Frequency generator with an oscillator along with amplifier for converting AC current to DC • Also has circuit that tunes to patient • Treatment applicator is either condenser or inductive type • With condenser, patient is part of circuit and requires use of flexible electrodes • Inductive – utilizes drum or cable electrodes © 2011 McGraw-Hill Higher Education. All rights reserved