1 / 22

Manual MS/MS spectra interpretation

Manual MS/MS spectra interpretation. Practical course 24 .09.2013. Overview of fragmentation modes. CID: collision induced dissociation HCD: higher energy collision induced dissociation ETD: electron transfer dissociation. CID, ETD. HCD. Typical scan cycle.

kenyon
Download Presentation

Manual MS/MS spectra interpretation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Manual MS/MS spectra interpretation Practical course 24.09.2013

  2. Overview of fragmentation modes • CID: collision induced dissociation • HCD: higher energy collision induced dissociation • ETD: electron transfer dissociation CID, ETD HCD

  3. Typical scan cycle • Accumulation of 1e6 intact peptide ions in linear ion trap • Transfer of intact peptide ions into orbitrap and acquisition • Overfilling of linear ion trap and isolation of ~3e4 precursor ions in linear ion trap • Fragmentation of precursor ions and acquisition of fragment spectrum (MS/MS)

  4. Characteristics of CID and HCD • CID • Peptides are fragmented in an ion trap • “low energy” fragmentation • Peptides undergo multiple collisions with inert gas molecules • Additional excitation (RF pulse) required • HCD • Peptides are fragmented in dedicated fragmentation cell (quadrupole, octopole) • “high energy” fragmentation • Peptides are accelerated and collide with inert gas molecules • Peptides fragment instantaneously

  5. Characteristics of CID and HCD • CID • Works best for 2+/3+charge states • Efficient fragmentation • Sensitive detector (1 ion -> 1 detector count) • Produces predominantly b and y ions • Low mass cutoff • Low resolution/mass accuracy • Fragment charge state determination (>1+) impossible • HCD • Efficient fragmentation • Detector less sensitive (~5 ions required for orbi signal) • Produces mainly y ions, but also internal ions • No low mass cutoff • High resolution/mass accuracy • Fragment charge states

  6. Peptide fragmentation nomenclature

  7. Peptide fragmentation • Mechanism

  8. Peptide fragmentation • MS/MS spectra

  9. y1 ions • If you have performed a trypsin digest then one of these ions should be present in the MS/MS fragmentation spectrum and this will reveal the C-terminal residue.  • Hint: The N-terminal b1 ion is never observed but often the b1 ion can be observed after acetylation of the peptide. 1xOH = 17,00274 1xH = 1,00783 1xH+ = 1,00728

  10. y1 ions

  11. MS/MS interpretation • Good MS/MS spectrum

  12. MS/MS interpretation • Example exercise m/z 448.22 z =2

  13. MS/MS interpretation • Example exercise m/z 448.22 z =2

  14. MS/MS interpretation • Example exercise m/z 448.22 z =2

  15. MS/MS interpretation • Example exercise m/z 448.22 z =2

  16. MS/MS interpretation • Example exercise m/z 448.22 z =2

  17. MS/MS interpretation • Example exercise m/z 448.22 z =2

  18. MS/MS interpretation • Example exercise m/z 448.22 z =2

  19. MS/MS interpretation m/z 448.22 (2+) [M+H] = 895.43 • Example exercise

  20. MS/MS interpretation m/z 448.22 (2+) [M+H] = 895.43 • Example exercise

  21. MS/MS interpretation m/z 448.22 (2+) [M+H] = 895.43 • Example exercise

  22. MS/MS interpretation m/z 448.22 (2+) [M+H] = 895.43 • Example exercise

More Related