trigger efficiency in endcap with muons from w candidates
Download
Skip this Video
Download Presentation
Trigger Efficiency in Endcap with muons from W candidates

Loading in 2 Seconds...

play fullscreen
1 / 10

Trigger Efficiency in Endcap with muons from W candidates - PowerPoint PPT Presentation


  • 112 Views
  • Uploaded on

Trigger Efficiency in Endcap with muons from W candidates. Takashi Kubota(ICEPP, the Univ. of Tokyo), WZO meeting @ CERN May. 21 th , 2010. Outline.

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Trigger Efficiency in Endcap with muons from W candidates' - kenna


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
trigger efficiency in endcap with muons from w candidates

Trigger Efficiency in Endcap with muons from W candidates

Takashi Kubota(ICEPP, the Univ. of Tokyo),

WZO meeting @ CERN

May. 21th, 2010

outline
Outline
  • The list of Wevents found in express stream circulated in the atlas-phys-sm-wzobservation@cern.ch: “W/Z Candidates in Runs 155073 - 155116”
  • Checked if (Endcap) trigger is working fine w/ isolated high-pt muons coming from Z
  • Using MuonID Ntuple: https://svnweb.cern.ch/trac/atlasoff/browser/PhysicsAnalysis/MuonID/MuonIDAnalysis/MuonIDNtupleMakers/tags/MuonIDNtupleMakers-00-03-05

RoIs in +- 3Bunches, perform track-RoI matching by track extrapolation in Endcap, judge TGC trigger condition

dataset and event selection
Dataset and Event Selection
  • data10_7TeV.00155[073, 112, 116].physics_MuonswBeam.recon.ESD.f255
    • Integrated Luminosity ~ 4.7 nb-1 (from MCP2010 Twiki)
    • due to L1_MBTS_2 + EF_mu4_MSOnly_MB2_noL2_EFFS, not necessarily passed L1_MU*
  • Preselection: MCP_2010_v0.14xml, BCID, GoodTiming (MBTS<10, LAr<5)

a

  • using staco container
  • as described in Twiki
  • WZObservationWithMuons
  • other than n90

b

after a: 39 W’s remain

after b: 16 W’s remain

after c: 16 W’s remain

c

w event candidates
W event candidates
  • 16 candidates found in total
  • Perform matching by extrapolation in Endcap, then judge trigger condition (3-station or not?)
  • Take every RoIs in Barrel

:Endcap

:Barrel

L1_MU0, MU6, MU10, MU0_COMM, MU20

L2_mu4, mu6, mu10, mu15, mu20

EF_mu4, mu6, mu10, mu15, mu20

EF_mu4_MSOnly_MB2_noL2_EFFS

w event candidates1
W event candidates
  • Endcap missed 1 L2, and 3 EF single muon items
  • TGC L1 is going well in terms of Efficiency(100%) and timing (all in 0 BC)
  • Timing stretch in Barrel saves a lot of W’s

:Endcap

:Barrel

L1_MBTS_2, EF_mu4_MSOnly_MB2_noL2_EFFS…

distributions
Distributions

phi

pT

eta

MET

|z0 - zvtx|

MT

run155116 lb32 6398227
Run155116, LB32, #6398227

EventNumber = 6398277 of the Run: 155116MET RefFinal :75.4 (GeV) MET Topo+Mboy :59.16 (GeV) # of PV: 2PV #1: nTracks = 20: z = 77.05 (mm)PV #2: nTracks = 0: z = 77.05 (mm)# of Muons Muid:1 Staco:1Muid #1: eta = 2.197: phi = -2.115: comb_pt = 24.17 ms_pt = 22.78: isolation = 0 : matchChi2 = 16.45: #Pix = 4: #SCT = 8: #MDT = 23 : #TrigPhi = 5: #TrigEta = 5: matched ROI_ID = 0Staco #1: eta = 2.196: phi = -2.115: comb_pt = 23.54 ms_pt = 21.43: isolation = 0 : matchChi2 = 34.1: #Pix = 4: #SCT = 8: #MDT = 23 : #TrigPhi = 5: #TrigEta = 5: matched ROI_ID = 0MUID MT for Muon #1 = 77.36STACO MT for Muon #1 = 69.04L2_mu20 = L2_passedRawEf_mu20 = L2_passedRaw

L1_MU20 = L1_passedRaw EF_mu4_MSonly_MB2_noL2_EFFS = EF_passedRawL1_MBTS_2 = L1_passedRaw# of MuonRois: 1muRoi #0 in Endcap: bcOffset = 0: eta = 2.178: phi = -2.116 : threNum = MU20: pt = 20: 3-station = 1

run155116 lb60 14061760
Run155116, LB60, 14061760

EventNumber = 14061760 of the Run: 155116MET RefFinal :37.48 (GeV) MET Topo+Mboy :39.3 (GeV) # of PV: 2PV #1: nTracks = 66: z = -2.35 (mm)PV #2: nTracks = 0: z = -2.35 (mm)# of Muons Muid:2 Staco:2Muid #1: eta = 1.914: phi = -0.9467: comb_pt = 46.15 ms_pt = 46.06: isolation = 0 : matchChi2 = 9.336: #Pix = 4: #SCT = 11: #MDT = 19 : #TrigPhi = 5: #TrigEta = 5: matched ROI_ID = 0 : #TrigPhi = 0: #TrigEta = 0: matched ROI_ID = -1Staco #1: eta = 1.914: phi = -0.9467: comb_pt = 46.82 ms_pt = 46.78: isolation = 0 : matchChi2 = 8.307: #Pix = 4: #SCT = 11: #MDT = 19 : #TrigPhi = 5: #TrigEta = 5: matched ROI_ID = 0MUID MT for Muon #1 = 82.78STACO MT for Muon #1 = 85.61L2_mu20 = L2_passedRawEf_mu20 = L2_passedRawL1_MU20 = L1_passedRaw

EF_mu4_MSonly_MB2_noL2_EFFS = EF_passedRaw L1_MBTS_2 = L1_passedRaw# of MuonRois: 1muRoi #0 in Endcap: bcOffset = 0: eta = 1.909: phi = -0.9292 : threNum = MU20: pt = 20: 3-station = 1

run155112 lb234 25389334
Run155112, LB234, 25389334

EventNumber = 25389334 of the Run: 155112MET RefFinal :71.98 (GeV) MET Topo+Mboy :57.4 (GeV) # of PV: 2PV #1: nTracks = 65: z = -13.26 (mm)PV #2: nTracks = 0: z = -13.26 (mm)# of Muons Muid:1 Staco:1Muid #1: eta = -1.783: phi = -0.4146: comb_pt = 36.86 ms_pt = 31.63: isolation = 0 : matchChi2 = 7.887: #Pix = 4: #SCT = 10: #MDT = 19 : #TrigPhi = 8: #TrigEta = 8: matched ROI_ID = 0Staco #1: eta = -1.783: phi = -0.4146: comb_pt = 36.7 ms_pt = 32.29: isolation = 0 : matchChi2 = 8.621: #Pix = 4: #SCT = 10: #MDT = 20 : #TrigPhi = 7: #TrigEta = 7: matched ROI_ID = 0MUID MT for Muon #1 = 86.51STACO MT for Muon #1 = 80.43Highest Pt Trigger in the event:L2_mu20 = L1_passedRawEf_mu20 = L1_passedRawEF_mu4_MSonly_MB2_noL2_EFFS = EF_passedRawL1_MU20 = L1_passedRawL1_MBTS_2 = L1_passedRaw# of MuonRois: 2muRoi #0 in Endcap: bcOffset = -1: eta = -1.773: phi = -0.4414 : threNum = MU20: pt = 20: 3-station = 1muRoi #1 in Endcap: bcOffset = 0: eta = -1.773: phi = -0.4414 : threNum = MU0: pt = 4: 3-station = 1

summary
Summary
  • Checked Trigger situations with muons in W event candidates, TGC fired w/ 100% efficiency and all RoIs are in current bunch and satisfy 3-station condition
  • Endcap HLT missed 3/10 EF and 1/10 L2
ad