1 / 14

EVAPOCLEAN TM

EVAPOCLEAN TM. CLOSED ENVIRONMENT EVAPORATION DEVICE. ACID AND SOLVENT PURIFICATION. ACID AND SOLVENT EVAPORATION FOR TRACES ANALYSIS. PATENTED. SAMPLE DIGESTION. CLEANING STATION.

keene
Download Presentation

EVAPOCLEAN TM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EVAPOCLEAN TM CLOSED ENVIRONMENT EVAPORATION DEVICE ACID AND SOLVENT PURIFICATION ACID AND SOLVENT EVAPORATION FOR TRACES ANALYSIS PATENTED SAMPLE DIGESTION CLEANING STATION EVAPOCLEAN arise from the collaboration of the ANALAB compagny and the researchers of the NATIONAL CENTER for SCIENTIFIC RESEARCH allocated to a laboratory of the PHYSICAL Institut of the Globe of Paris

  2. 1 EVAPOCLEANTM CLOSED ENVIRONMENT EVAPORATION DEVICE FIVE MAJOR ADVANTAGES OF THE EVAPOCLEAN THE EVAPOCLEAN ALLOWS YOU TO EVAPORATE SOLUTIONS totally or partially, at constant and controlled temperature, reducing possible matrix interferences, with good recoveries down to ppt levels, without external contamination. IT PRODUCES ULTRA-PURE CHEMICALS by sub-boiling distillation and greatly reduces the costs related to the purchase of sub-ppb ultra-pure reagents (HCI, HF, HNO3, HClO4, H2SO4, ,NH4OH, H2O2,…) THE ACIDIC DIGESTION HOLES allow you to simultaneously solubilize several samples [up to 28 samples at a time]. THE CLEANING of elbows and containers are easily achieved without additional cleaning systems, with reduced handling of cleaning reagents. THE SYSTEM WORKING AS A CLOSED ENVIRONMENT protects your staff and your laboratory against corrosive vapors. It reduces greatly your operating costs while avoiding any investment in vapor neutralization systems, scrubbers and pumps.

  3. 2 EVAPOCLEANTM CLOSED ENVIRONMENT EVAPORATION DEVICE SIMPLICITY OF USE: A TECHNICAL CHOICE ALL SURFACES ARE COVERED WITH TEFLON® A RELIABLE EQUIPMENT STURDY EQUIPMENT REQUIRING NO MAINTENANCE CABLES AND CONNECTORS ARE PROTECTED

  4. 3 EVAPOCLEANTM PRINCIPLE OF OPERATION OPTIMAL HEATING-SURFACE OF CONTAINERS. DIGESTION and VAPOR CLEANING Condensation area GRAPHITEHEATING BLOCK ELBOW COLD ZONE VAPORS CUP SAMPLE [MATRIX AND TRACE ELEMENTS] CUP CONDENSED MATRIX THE SUB-BOILING EVAPORATION OF THE CHEMICAL MATRIX TO BE ELIMINATED OR TO BE CLEANSED TAKES PLACE UNDER CONSTANT, HOMOGENEOUS AND CONTROLLED TEMPERATURE. THE VAPORS, ISOLATED FROM THE SURROUNDING ATMOSPHERE, ARE CONDENSED AND CHANNELLED IN THE COLD ZONE. CONTAMINANTS IN TRACES REMAIN IN THE EVAPORATED CUP.

  5. 5 EVAPOCLEANTM CLOSED ENVIRONMENT EVAPORATION DEVICE HOMOGENOUS TEMPERATURE BETWEEN SAMPLES. EXCELLENT RECOVERY RATES HIGH - PERFORMANCE DEVICE PROGAMMABLE TEMPERATURE IN RAMP OR PLATEAU BY DEDICATED REGULATOR. EVAPORATION SPEED RATE ADJUSTABLE.

  6. 7 EXAMPLES OF RECOVERY DATA with EVAPOCLEAN 12p125 [Analysis of sub-ppb Semiconductor grade chemicals by ICP-MS] 50 ppt Spikes 100ppt Spikes 500ppt spikes

  7. 11 EVAPOCLEANTM HANDLING OF ELBOWS AND CUPS THIS FUNCTIONAL STAND, ALLOWS SAFE HANDLING OF ELBOWS AND CUPS BEFORE AND AFTER EVAPORATION

  8. PUMP 12 EVAPOCLEANTM ABOLISH THE SYSTEM OF NEUTRALIZATION OF THE ACID VAPORS AS DURING THE USE OF MICRO-WAVES, HEATING PLATES, BATHS OF SAND SYSTEME UNDER GAS STREAM. ACID VAPORS BATHS OF NEUTRALIZATION NO MORE STOCKING OF NEUTRALIZING PRODUCTS NO MORE IMMOBILIZATION OF MONEY

  9. EVAPOCLEANTM 14 TECHNICAL CHARACTERISTICS OF CUPS AND ELBOWS 1. THE CHOSEN MATERIALS IN TEFLON® PTFE AND PFA ARE CONSISTENT WITH MINIMAL CONTAMINATION. 2. PRESSURE TEST OF TEFLON® PFA CUPS [33 ml] : UNDER 5 bars PRESSURE (70.5 PSI), 10 ML WATER @100°C (212°F): NO DETERIORATION. 3. PRESSURE MEASUREMENT OF A 33 ml PFA CUP CONTAINING 10 ml OF WATER @ 100°C (212°F): THE MAXIMUM PRESSURE MEASURED WAS 0,6 bars (8,7 PSI) ABOVE ATMOSPHERIC PRESSURE. TESTS MADE VOLUNTARLY BEYOND NORMAL CONDITIONS OF USES CAUTION:CUPS ARE NOT FORESEEN TO BE USE UNDER HIGH PRESSURES. PRELIMINARY TESTINGS ARE RECOMMENDED.

  10. EVAPOCLEANTM 15 CONTAMINATION RATE AND MEMORY EFFECT EVAPORATION, of concentrate solution (HNO3 at 70°C) in 4 hours. Measured by ICP-MS.

  11. EVAPOCLEANTM 17 AVALAIBLE MODELS MODEL 1 EVAPOCLEAN 6p25 = 6 Evaporation positions and 14 Digestion / Cleaning positions.Accepts Cups of 17-24-33-60 ml brim capacity [diameter: 29 mm]. Allows Evaporation of samples up to 25 ml. 14 Digestion holes on top of the Device [These holes can be use also for Cups and Elbows cleaning]. EVAPOCLEAN 12p25 = 12 Evaporation positions and 28 Digestion / Cleaning positions. :similar to the 6p25 Evapoclean, but with 12 Evaporating positions and 28 Digestion holes. Same Cup sizes. EVAPOCLEAN 6p25.STSimilar to 6p25 but without Digestion Holes on top of the Device. Same Cup sizes. EVAPOCLEAN 12p25.STSimilar to 12p25 but without Digestion Holes on top of the Device. Same Cup sizes. MODEL 2 EVAPOCLEAN 6p125 = 6 Evaporation positions and 14 Digestion / Cleaning positions.Accepts Cups of 65-95-185 ml brim capacity [diameter: 49 mm]. Allows Evaporation of samples up to 90 ml. 14 Digestion holes on top of the Device. EVAPOCLEAN 12p125 = 12 Evaporation positions and 28 Digestion / Cleaning positions. :similar to the 6p125 Evapoclean, but with 12 Evaporating positions and 28 Digestion holes. Same Cup sizes. EVAPOCLEAN 6p125.ST:Similar to 6p125 but without Digestion Holes on top of the Device. Same Cup sizes. EVAPOCLEAN 12p125.ST:Similar to 12p125 but without Digestion Holes on top of the Device. Same Cup sizes. EVERY EVAPOCLEAN IS DELIVERED WITH THE NUMBER OF ELBOWS IN TEFLON® AND CONTAINERS IN P.F.A CORRESPONDING TO THE ORDERED MODEL.EXEMPLE: EVAPOCLEAN 6p25 IS DELIVERED WITH 6 ELBOWS AND 12 P.F.A CUPS [mention Selected Cup sizes when ordering].

  12. EVAPOCLEANTM 21 EVAPOCLEAN 6 POSITIONS WITH ALL ACCESSORIES 8 6 7 4 2 3 1 5 1 .REGULATOR 2 . PROBE OF TEMPERATURE INTERNAL 3 . EVAPORATING OF MICRO VOLUMES 4 . INTERNAL CLEANING OF ELBOWS 5 . EVAPORATION AND DISTILLATION BIG VOLUMES 6 . INTERNAL CLEANING OFCONTAINERS 7 . AREA OF SOLUBILIZATIONS OF SAMPLES 8 . CONTAINERS 60 ml, 90 ml, 180 ml

  13. EVAPOCLEANTM 22 FLEXIBILITY OF THE DEVICE THE DEVICE ALLOWS THE USE OF DIFFERENT SIZES CUPS, BY INSERTION OF GRAPHITE WEDGES IN THE HOLES. BEING MANUFACTURED IN THE SAME GRAPHITE MATERIAL AS THE HEATER BLOCK, THEY INSURE AN HOMOGENEOUS HEATING OF THE SAMPLES. DIGESTION POSITIONS [also used for Cups and Elbows Cleanings] WEDGES WEDGES ELBOW Evaporation EVAPORATION PROCESS, PURIFICATION OF ACIDS & SOLVENTS, CLEANING OF CUPS AND ELBOWS. Condensation WEDGES CUP

  14. CONTACT US FOR MORE INFORMATION Analab sarl 23 route de la Wantzenau BP 40141 Hoenheim 67804 Bischheim cedex France Tél.00.33.(0)388.517.951 Fax.00.33.(0)388.517.913 E-mail. analab@wanadoo.fr Website. analab.fr Please contact: Michel Gaertner

More Related