An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SPELL SCHOOL

  2. DEPARTMENT OF COMMUNITY AFFAIRS BUILDING CODES & STANDARDS MANUFACTURED BUILDINGS PROGRAM MICHAEL D. ASHWORTH, MANAGER 850-922-6075 michael.ashworth@dca.state.fl.us

  3. FACTORY BUILT SCHOOLS(PORTABLES)

  4. STATUTORY AUTHORITIES • S. 553.415 FS —GOVERNS PORTABLE CLASSROOMS UNDER THE FBC (DCA)—(PROPOSED DELETION) • RULE 9B-1.O26, 028 & 030 FAC—ADDITIONAL PROCEDURES • S. 1013.20 FS--AUTHORIZES 5 YR PLAN & EXEMPTION FROM FBC (DOE)—SUNSETS FEB, 2008, (UNLESS EXTENDED BY LEGISLATURE).

  5. NEW CONSTRUCTION TYPE II-B (OLD IV) (“SREF”)(pg.1) • PLANS REVIEWED BY CRA • MFG’D BY DCA APPROVED MFGR • INSPECTED AT PLANT BY SCHOOL B.O. OR 3RD PARTY AGENCY (S.553.415(9) FS)-(PROPOSED DELETION). • “SREF” INSIGNIA NOW INSTALLED AT THE FACTORY (see next slide)

  6. TYPE II-B (SREF) (pg.2) • SITE INSPECTIONS ARE SCHOOL’S RESPONSIBILITY. (No longer req’d by DCA; Still req’d by DOE). • NO INSPECTION REPORTS/NO INSIGNIA ORDERED ONLINE (NEW CONST.) (Deleted by Rule 9B-1 change).

  7. TYPE II-B (SREF) (pg.3) • “SREF” INSIGNIA ISSUED; AFFIXED BY THIRD PARTY AGENCY AT PLANT (Rule 9B-1 change) • LEASED PORTABLES TREATED SAME AS OWNED (INSIGNIAS; ETC) • INSTALLED BY LICENSED CONTRACTOR/B.O.--PERMIT

  8. TYPE II-B (SREF) (pg.4) • SITE PLANS NOT REVIEWED BY CRA • DUAL PLANS REVIEWS NOT NEEDED (CRA + 3RD PARTY AGENCY) • CRA DOES PRODUCT APPROVAL & 633 REVIEW • CBPB-DISCUSS

  9. Q & ATYPE II-B (ONLY)(EXISTING PORTABLES-- NEXT) ???

  10. EXISTING BLDGS TYPE III-B (OLD V) & V-B (OLD VI) CONST.

  11. 2001 FBC2004 FBC Type I Type I-A Type II Type I-B Type III Type IV Type IV 1-hour Protected Type II-A Type IV Unprotected Type II-B Type V 1-hour Protected Type III-A Type V Unprotected Type III-B Type VI 1-hour Protected Type V-A Type VI Unprotected Type V-B EXISTING BLDGS--APPENDIX DTYPE OF CONSTRUCTION

  12. TYPE III-B & V-B (EXISTING) (pg.1) • PLANS REVIEWED BY THIRD PARTY AGENCY (RECERTIFICATION). • SITE & ANNUAL INSPECTIONS BY SCHOOL (S.1013.20 FS-DOE) • INSIGNIA ORDERED ONLINE (BCIS) • LEASED PORTABLES MUST BE BEAR “SREF” INSIGNIA

  13. TYPE III-B & V-B (EXISTING) (pg.2) • PORTABLES IN 5 YR PLAN (FBC NON-COMPLIANT) ARE NOT ELIGIBLE FOR DCA INSIGNIA (SUNSETS FEB, 2008); OK TO HOUSE STUDENTS W/ COMPLETED SITE & ANNUAL INSPECTIONS (SUNSETS FEB, 2008)

  14. TYPE III-B & V-B EXISTING (pg.3) • RELOCATION TO SAME WIND SPEED DESIGN=NO RECERT/NO NEW DCA INSIG; (IF REQD BY LOCAL B.O.= 3rd PARTY AGENCY or LOCAL B.O.) • RELOCATION TO HIGHER WIND SPEED DESIGN = RE-ENGINEERING OF PLANS (& POSSIBLY, BLDG) TO OBTAIN RECERTIFICATION.

  15. TYPE III-B & V-B EXISTING (pg.4) • RECERTIFICATIONS -- ALL SITE INSTALLATION (FOUNDATION, ETC.,) MUST COMPLY WITH LOCAL WIND SPEED DESIGN REQMNTS. • NO (HUD STANDARD) MOBILE HOMES CAN BE USED TO HOUSE STUDENTS.

  16. TYPE III-B & V-B EXISTING (pg.5) • OFF-CAMPUS SCHOOL BOARD OFFICES, STORAGE SHEDS, ETC., NOT HOUSING STUDENTS DO NOT HAVE TO BE “SREF” COMPLIANT. • ALL PORTABLE CLASSROOMS BUILT PRIOR TO 03/01/02 SHOULD HAVE A DCA INSIGNIA (see next slide), UNLESS IN THE 5 YR PLAN.

  17. QUESTION & ANSWER ???