Training CourseSuperCool 1000 Level 1 Course #P0131
Contents • Module 1: Introduction • Module 2: Inputs and Outputs • Module 3: Features • Exam
LCD display for ease of programming LED display readable at a distance Manual switch for mist Pilot lights indicate status of controller outputs 75.4 M1 Tº 72.0 ºF Pr. Act: 123456 Rapid-access function keys
System • Controls the operation of a high pressure nozzle system by keeping track of humidity and temperature levels. • The high pressure nozzle system is the one sold by Victoria Equipment. • Controls stir fans. • Dairy cows are the main application. It can also be used for poultry and hog production. Click on image to view video.
What the Client Gets • Controller; • 1 temperature probe; • Contactor box for pump; • Instruction manual / wiring diagram. Product Options • Up to 3 relative humidity sensors; • Indoor or outdoor temperature probes; • Valve; • Pressure switch; • Water meter; • Configuration module; • Comlink-1 for communications (Bridge)
6 x indoor Tº probes 1 x outdoor Tº probe 3 x indoor relative humidity sensors 1 x water meter 1 pressure switch 1 mist output 1 pump 1 mist valve 1 drain valve 3 fan groups. Inputs and Outputs
Input: Relative Humidity Sensors • You can select sensors to use. • Allows for various strategies: • Misting: • Compensation on pump operating times; • Stop pump if RH too high. • Operation of fan groups according to RH level • History record over 7 days for minimum and maximum values.
Output: Mist • Operates according to 4 intensity levels. For each level, user must indicate: • Start and stop temperature; • Timer settings. • For example: Intensity
Output: Mist (cont’d) • Depending on RH level, controller will modify timer operating times in 2 ways: • Humidity lower than comfort zone: Time Off is decreased • Humidity higher than comfort zone: Time On is decreased Current Current 50% = % Time Off 50% = % Time On RH Comfort Zone No compensation Pump will operate for a shorter period Pump will stop for a shorter period Max Compensated Max Compensated %RH 90% 50% 60% 80% Low RH set-point High RH set-point
Output: Mist (cont’d) • Mist operation can be shut off: • If RH level too high; • During the night. • Mist can be activated if RH too low (dust control)