An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2012 DCPM Changes This presentation is to summarize the changes to the DCPM that are proposed from the 2011 version

  2. What is the DCPM? • D – Design [dih-zahyn] • to prepare the preliminary sketch or the plans for (a work to be executed), especially to plan the form and structure of: to design a new bridge. • C - Construction [kuhn-struhk-shuhn] • the way in which a thing is constructed: a building of solid construction. • P – Practice [prak-tis] • habitual or customary performance; operation: office practice. • M – Manual [man-yoo-uhl] • a small book, especially one giving information or instructions

  3. What is the purpose of DCPM? • The purpose of this manual is to consolidate the rules, regulations and guidelines covering the design and construction of water and wastewater facilities within the service areas of the Anchorage Water and Wastewater Utility (AWWU). • The complexity of our system necessitates standardizing design practices which will provide a consolidated guideline to facilitate proper maintenance of the system.

  4. What Rules? • AWWU Tarriff • Wastewater utility • Water utility • 10-State Standards • Others not specifically listed here

  5. What Regulations? • EPA – Safe Drinking Water Act (SDWA) & CFR’s • ADEC – Alaska Administrative Code (AAC) 18 – Environmental Conservation • Chapter 70 – Water Quality Standards • Chapter 72 – Wastewater Treatment and Disposal • Anchorage Municipal Code (AMC) – • Title 21 – Land Use Planning • Title 23 – Building Codes • Title 24 – Streets & Rights of Way • Title 26 – Utilities • Others not specifically listed here

  6. What Guidelines? • American Water Works Association Standards • Manufacturer’s recommendation • Ductile Iron Pipe Association – DIPRA • Plastic Pipe Institute • PVC Pipe Association • Others not specifically listed here

  7. What is the history of the DCPM • 1990 – Issued by Richard Besse, GM (first saved copy) • 1994 – Updated Under Mark Premo, GM • 2003 – Update Started but not completed • 2004 - Updated Under Mark Premo, GM • 2007 – Update Started but not completed • 2008 – Update Started but not completed • 2010 – Updated Under Mark Premo, GM • 2011 – Updated Under Mark Premo, GM • 2012 – Update in progress

  8. Who does the DCPM impact? Rate Payers Engineers Contractors Developers AWWU Operations and Maintenance Other City Governments by reference to MOA MASS & DCPM And anyone else who interfaces with the above including policy makers

  9. Rate Payers • Provides a method of delivering safe, high quality water at a reasonable rate • Ensures compliance and responsible wastewater collection and treatment • Ensure longevity of the water/wastewater system to reduce and/or control rate increases due to replacement of existing infrastructure • Efficient and orderly development to maintain quality of life metrics (housing values, healthy living)

  10. Engineers • The DCPM reduces design costs by implementing a “play book” in which the designer and utility employees can work from to promote orderly, efficient, and enduring infrastructure.

  11. Contractors • The DCPM provides clear and concise requirements for durable infrastructure construction • Allows AWWU to inform Contractors installing AWWU infrastructure of expectations facilitating ease of construction and reduce rework

  12. Developers • The DCPM ensures that all parties are working from one standard. • Promotes transparency of AWWU requirements

  13. AWWU Operations & Maintenance • The DCPM incorporates lessons learned from existing materials and practices to promote longevity of the infrastructure • Streamline inventory by installing consistent products such as valves, fire hydrants, and pipe materials

  14. Others • AWWU appears to be leading other communities in Alaska developing standards for infrastructure installation, rehabilitation, and maintenance as such they reference our manual. • This is a best practice as identified in benchmarking projects AWWU has participated in

  15. How is it set up?

  16. Sections • Section 10 – General • Section 20 – Items that are applicable to both water and sewer • Section 30 – Items only applicable to sewer • Section 40 – Items only applicable to water • Section 50 – Items applicable to record drawings • Section 60 – Drafting, notes and presentation styles • Section 70 – Appendices, SCADA, abbreviations, definitions

  17. What are the changes? Material changes – Specific Items Grammatical Update (legalese) - Example Organization - Example Add / remove requirements - Example Remove duplicated text - Example

  18. Material Changes – New Requirements • Trace wire for all non-metallic pressure pipe • Warning tape for all pipe installations • Fusion bonded epoxy coatings on all fittings

  19. Material Changes • Specified fittings commonly used in design and construction: • Section 30 – Sewer Fittings • Inflow Dish required on water tight manholes

  20. Material Changes • PVC over insertion protection device – EBAA Iron Mega-Stop™ Prior to insertion After insertion The why – over insertion caused break

  21. Material Changes • Require stainless steel key box rod

  22. Grammatical Updates - Example Shall versus Must (most of the changes to the DCPM had to do with this) Correct usage The engineer shall submit plans. Legal translation The engineer has a duty to submit plans.

  23. Grammatical Updates - Example Shall versus Must (most of the changes to the DCPM had to do with this) Incorrect usage The pavement shall be saw cut. Legal translation The pavement has a duty to be saw cut The pavement cannot have a duty, thus: The pavement must be saw cut.

  24. Organization – Example Change • 2011 DCPM – Pavement removal • Previous Location Section 30 – Sewer

  25. Organization – Example Change • 2012 DCPM – Pavement removal • New location Section 20 – Water and Sewer

  26. Add/remove requirements • Corrosion Control and Study DCPM Section 20.10 • 2010 & 2011 Corrosivity evaluation report required for all projects

  27. Add/remove requirements • 2012 DCPM removes the requirement for a mandatory corrosivity evaluation if the design met AWWU minimums for corrosion protection: • 20.10.06 Standardized Corrosion Protection In recognition of AWWU’s commitment to ensure the longevity of our underground pipe assets while creating efficiencies in the design and construction of those assets; the requirement for a corrosivity evaluation will be removed when the design includes the following items: • Anodes installed on all metallic water/sewer main line & water services • Non-metallic water mains and apparatuses must have an anode on all metallic fittings with the limit that one anode may serve fittings and fire hydrants within 20’ of the anode with the exception of EBAA Iron Mega-Stop™ which does not require an anode. • Anodes installed at a regular interval of eighteen feet (18’) or less on sixteen inch diameter (16”∅) or smaller ductile iron pipe • Two zinc ribbon anodes with test stations installed on either side of sixteen inch diameter (16”∅) or greater ductile iron pipe. Ribbon anodes must be properly detailed and sized for the soil conditions. • Electrical continuity is installed and tested for all ductile iron pipe • Epoxy coating is specified for all fittings • Require protective coatings on all metallic pipe unless the engineer can demonstrate that groundwater is not present at the proposed burial depth of the pipeline. • Stainless steel bolts are specified for all bolts used to construct valves • Stainless steel bolts or blue bolts are specified for water fittings • Stainless steel operating rods for copper water services

  28. Remove Duplicate Text - example • 2011 DCPM 20.04.05 • 2011 DCPM 20.13.02 • 2012 DCPM merged 20.04.05 & 20.13.02 into one location:

  29. How Much will it Cost? Estimated cost impacts Private Development Projects Capital Improvement Projects Operations and Maintenance

  30. What are the potential savings for private developers • Private developers can expect cost savings in these areas: • AWWU is to provide modeling of fire and waste flows ($500) • Removed requirement for unified AutoCAD drafting (layer names) and geographical information ($1,000-$2,500) • Shortened required length of mainlines in Cul-de-sacs ($50) • Removed mandatory requirement for corrosion evaluation reports ($3,000-$5,000) • Removed requirement for tightly bonded coated sewer DIP ( $500-$1,000/stick) • Streamlined process to construct service extensions beyond other utilities ($100-$500) • Removed SCADA requirement for private lift stations ($2,500-$10,000)

  31. What are the potential additional costs for private developers • Private developers can expect cost increases in these areas: • Expanded the use of Stainless steel to key box rods ($100-$200) • Expanded requirements of water shutoff notifications ($100-$200) • Require all fittings to be epoxy coated ($30-$50 per fitting w/o accounting for savings by not having to use denso paste/tape) • Require the use of tracer wire on all non-metallic pipe ($50) • Require the use of an over insertion device for PVC pipe installation ($50-$100 per joint)

  32. What will it cost/save the Capital Improvement Program • Reduces cost associated with: • Corrosion study • Increased costs associated with: • Stainless steel key boxes • Water outage notification • Over insertion device for PVC pipe

  33. What will it cost/save Operations and Maintenance • Reduces cost associated with: • Mainline breaks • By increasing the longevity of newly installed assets • Stainless steel key box rods • Epoxy coated fittings • Standardized cathodic protection (conservative protection) • Increased costs associated with: • Stainless steel key boxes

  34. Rollout Schedule Schedule Scheduled meetings Public Notices Policy Memo – Notice Period for Changes to Construction

  35. Rollout • Revisions – Continuous Improvement • Edits to the manual started in early December 2011 • Draft 2012 DCPM is published • January 19, 2012 • Review meetings • Field Services – December 14th, 2011 • CIP Staff – February 2, 2012 • Public – February 16, 2012 • Draft 2012 DCPM comment period closure • February 21, 2012 • Final DCPM Published • March 7, 2012

  36. Public Notice – Post Card

  37. Public Notice – Email

  38. Policy Memo Notice Period

  39. Upcoming foreseeable changes Impacts from the Corrosion Master Plan Manhole infiltration requirements PVC Restraint – Belt and Suspenders Modification of the Municipality of Anchorage Standard Specifications (MASS) Dewatering requirements – ADEC, Contaminated sites, DNR permitting

More Related