1 / 23

Design and validation of a Solar Domestic Hot Water Heating Simulator

Thomas Cemo April 29, 2009. Design and validation of a Solar Domestic Hot Water Heating Simulator. Department of Mechanical Engineering Baylor University. Outline. Introduction Background Assumptions Theory Apparatus Results Conclusions. Introduction: Goals.

july
Download Presentation

Design and validation of a Solar Domestic Hot Water Heating Simulator

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thomas Cemo April 29, 2009 Design and validation of a Solar Domestic Hot Water Heating Simulator Department of Mechanical Engineering Baylor University

  2. Outline • Introduction • Background • Assumptions • Theory • Apparatus • Results • Conclusions

  3. Introduction:Goals • To accurately simulate efficiency ratings provided by the Solar Rating and Certification Corporation (SRCC). • To create a platform for testing modifications to domestic solar hot water heating systems.

  4. Background:Domestic Hot Water heating • The home is the second largest non-commercial consumer of energy, behind transportation. • 14% to 25% of domestic energy is demanded by water heating. • Solar thermal water heating has a tremendous opportunity to reduce this demand.

  5. Background:Solar Rating and Certification Corporation (SRCC) • Arab Oil Embargo of the 1970s • Federal tax credits motivated a rush to hastily install solar thermal systems. • The market was flooded with poor designs and craftsmanship. • Solar Rating and Certification Corporation (SRCC) Founded in 1980 • Reassures consumers of quality products. • Efficiency ratings will be used to validate our hardware simulation.

  6. BACKGROUND:DOUBLE TANK SYSTEMS • Water is heated as it is circulated through a collector. • Energy is transferred to thermal storage and auxiliary heating if necessary. • Hot water is then drawn for domestic uses such as dishwashing. Double Tank System

  7. Assumptions:Solar Day • How to accurately model the energy available during a typical day? • Standardized weather profile provided by the SRCC. • All calculations occur in an adjusted time frame known as Solar Time. Insolation (Whr/m2) Solar Day Solar Night Solar Night

  8. Theory: Solar Energy Factor Qdel: Thermal energy delivered to the domestic hot water load. Qpar:Energy required by parasitic devices such as pumps and controllers. Qaux:Energy required by auxiliary resistive heating elements. Average SEF: 2.0 - 5.0

  9. Theory:QdElDelivered Energy Solar ‘Day’ Draw Schedule

  10. Theory:Solar Fraction SF: Portion of hot water provided by solar energy. EF: Energy factor for a conventional electric hot water heater (0.9). SEF: Solar Energy Factor. Average Solar Fractions: 0.50 - 0.75

  11. Apparatus Solar Thermal Collector Simulator Mains Chiller Solar Storage Tank Auxiliary Storage Tank

  12. Apparatus: Solar Thermal Collector Simulator (STCS) • Simulates thermal collector absorbing insolation during a solar day within 10% accuracy. • LabVIEW Control Software calculates the useful power from the simulated collector array. • Modified Seisco on-demand hot water heater. • Resistive heating elements deliver power to circulated water.

  13. Apparatus:LabVIEW Control Software

  14. Apparatus:LabVIEW Control Software

  15. Apparatus:Mains Chiller Chiller tank • Test conditions require 14°C. • Baylor water mains temperature range from 15°C to 22°C. • Closed loop that circulated water through 60ft of copper submerged in an ice bath. • 19 gallons were cooled to 14°C in approximately 25 min. • Temperatures maintained within 0.4°C. Pump controls Ice bath

  16. Results:Double Tank Configuration Solene Double Tank Drainback System

  17. Results:Double Tank Configuration • Average Solar Fraction of 0.65 • Solar Savings =30,155 kJ/day • 8.3 kWh/day • Average Electricity cost $0.13/kwh* Yearly Savings: $388 *Average Retail Price of Electricity to Ultimate Customers by End-Use Sector, by State, EIA

  18. Results:Double Tank Configuration Solar Day

  19. Results:Double Tank Configuration Solar Day

  20. Conclusions • Constructed a test platform for future research into solar domestic water heating. • Calculated accurate and repeatable results verified by SRCC data.

  21. Recommendations • Incorporate a Differential Temperature Controller • Utilize location specific weather data • Construct an array of thermocouples to be inserted into the tanks.

  22. Acknowledgments • Departments of Mechanical and Electrical Engineering for providing the means to continue this research. • Dr. Van Treuren, Dr. Gravagne, and Dr. Lehr • Mr. Ashley Orr and Mr. Dan Hromadka

  23. Questions?