O verview of Fermilab Accelerator Complex and Beam Lines. T. Kobilarcik FNAL. Fermilab Accelerators. Linac Booster Main Injector Tevatron. Linac. 400 MeV protons. 15 – 50 m s spill at 15 Hz. 35 mA . Currently transports beam to MTA hall.

joyce
Download Presentation

O verview of Fermilab Accelerator Complex and Beam Lines

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Overview of FermilabAccelerator Complex and Beam Lines T. Kobilarcik FNAL

  2. Fermilab Accelerators • Linac • Booster • Main Injector • Tevatron Santa Fe Polarized Drell-Yan Workshop 2010

  3. Linac • 400 MeVprotons. • 15 – 50 ms spill at 15 Hz. • 35 mA. • Currently transports beam to MTA hall. • Hall is 40’ long, 21’ wide, and 16’ tall. • Probably need new facility. Santa Fe Polarized Drell-Yan Workshop 2010

  4. Booster • 8 GeV protons • 1.6 ms spill at 15 Hz; 53 MHz structure. • 5 x 10^12 protons per spill. • Currently transports beam toward MiniBooNE experiment via Booster Neutrino Beamline. Santa Fe Polarized Drell-Yan Workshop 2010

  5. Tevatron • Presently unable to deliver beam to fixed target experiments. • Historically: • 800 GeV protons • 20 second slow spill at 60 seconds; 53 MHz structure. • 1 x 10^13 protons per spill. • Single turn extraction possible Santa Fe Polarized Drell-Yan Workshop 2010

  6. Main Injector • 120 GeV protons. • 10 ms single turn extraction. • 1 to 4 second slow spill. • 53 MHz structure. • 60 second repetition rate. • Delivers beam to fixed target area. Santa Fe Polarized Drell-Yan Workshop 2010

  7. Fixed Target Area Santa Fe Polarized Drell-Yan Workshop 2010

  8. Fixed Target Area – NM Beamline • Presently used for E906/SeaQuest. • 5 x 10^12 protons per spill. Santa Fe Polarized Drell-Yan Workshop 2010

  9. Fixed Target Area – MT Beamline • Presently serves the Meson Test Beam Facility. • All rate are 100’s of kHz. • Primary Beam. • 120 GeV protons. • Secondary Beam. • Pion Mode: 1- 66 GeVpions or 200 MeVpions. Santa Fe Polarized Drell-Yan Workshop 2010

  10. Fixed Target Area – MC Beamline • Formerly housed the MIPP experiment • May re-commission beamline in within the year. • May be possible to target up to 2x10^12 protons per spill (once per minute) with shielding upgrade. • Can house ~225’ long beamlinewithing detector building. Santa Fe Polarized Drell-Yan Workshop 2010