slide1 n.
Download
Skip this Video
Loading SlideShow in 5 Seconds..
SRRp 2010, Bucuresti, 8 octombrie 2010 PowerPoint Presentation
Download Presentation
SRRp 2010, Bucuresti, 8 octombrie 2010

Loading in 2 Seconds...

play fullscreen
1 / 17

SRRp 2010, Bucuresti, 8 octombrie 2010 - PowerPoint PPT Presentation


  • 85 Views
  • Uploaded on

SRRp 2010, Bucuresti, 8 octombrie 2010. Implicarea Laboratorului de Metrologia Radionuclizilor din IFIN-HH in imbunatatirea calitatii masurarii 99m Tc in unitatile de medicina nucleara. M.Sahagia*, A. Luca, A.Antohe, A.C.Watjen, C.Ivan,

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'SRRp 2010, Bucuresti, 8 octombrie 2010' - jock


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

SRRp 2010, Bucuresti, 8 octombrie 2010

Implicarea Laboratorului de Metrologia Radionuclizilor din IFIN-HH in imbunatatirea calitatii masurarii 99mTc in unitatile de medicina nucleara

M.Sahagia*, A. Luca, A.Antohe, A.C.Watjen, C.Ivan,

Institutul National de C&D pentru Fizica si Inginerie Nucleara Horia Hulubei, IFIN-HH

Str. Atomistilor nr.407, 077125, Magurele, Jud. Ilfov

Corespondenta*: msahagia@nipne.ro

slide2
Rezultate recente ale Laboratorului de Metrologia Radionuclizilor (LMR) din IFIN-HH, suport pentru medicina nucleara

Asigurarea lantului de trasabilitate prin:

  • Etalonarea absoluta a radionuclizilor utilizati pentru radiofarmaceutice
  • Participarea la comparari internationale
  • Implementarea Sistemului de Calitate, aprobat de Technical Committee – Quality (TC-Q) al EURAMET
  • Echivalenta internationala este recunoscuta prin : 34 fisiere, Calibration and Measurement Capability (CMC) publicate in CIPM-MRA, Annex C, Data Base, www.bipm.org, in 2008.
  • Obtinerea acreditarii RENAR pentru LMR:

- Etalonare in Activitate

Certificat : LE 013/2009; la p. 9 figureaza Etalonarea calibratoarelor

- Incercare in Masurarea Activitatilor Joase

Certificat: LI 084/2009

  • Desemnare CNCAN ,2009, Laborator de Etalonare Notificat:

LE 05/2009

cadrul national si international
Cadrul National si International
  • Legislatia de Metrologie din Romania:

Calibratoarele de Radioizotopi din spitale nu sunt in lista mijloacelor de masura supuse controlului legal. Ele trebuie sa fie reetalonate dupa un program

  • Agentia Internationala pentru Energia Atomica a condus:

Coordinated Research Project (CRP) E2.10.05 “Harmonization of quality practices for nuclear medicine radioactivity measurements” 2004 – 2009.

Rezultatele CRP:

- Elaborararea de documente

  • Technical Report Series 454
  • Protocols for participation of the national laboratories at international

comparisons

  • Protocols for organization of the national comparisons with nuclear

medicine units .

- Organizatrea de comparari internationale : 131I si 57Co

- Organizarea de comparari nationale: 131I si 99mTc

  • LMR a participat la toate actiunile CRP.
publicatii
Publicatii :

International Atomic Energy Agency (IAEA)-Vienna, Austria - Technical Report Series 454 (TRS 454), 2006, ISBN 92-0-105306-1, ”Quality Assurance for Radioactivity Measurements in Nuclear Medicine” p.1-96, Contributors to drafting and review: M.Dondi, C.P.Herbst, A.Iwahara, M.Morengo, S. Mather, J.P. Norenberg, V.Olsovcova, P.Oropesa Verdicia, P.Otiz-Lopez, L.Joseph, M.Ghafoori, J.A.Onto, N. Ramamoorthy, M.Sahagia, K.R. Shortt, S.Tastan, P.Vincze, M.J.Woods, B.E.Zimmerman

Olsovcova, V., Iwahara, A., Oropesa, P.,Joseph, L., Rabindra, A., Ghafoori, M., Son, H-K., Sahagia, M., Tastan, S., Zimmerman, B. ”National comparisons of I-131 measurements among nuclear medicine clinics”.

Applied Radiations and Isotopes 6(2010)1371-1377

Zimmerman, B., E., Megzifene, A., Short, K.R. ”Establishing measurement traceability for national laboratories: Results of an IAEA comparison of 131I”. Appl. Radiat. Isot, 66, 6-7 (2008)954-959

Sahagia, M., Wätjen, A.C., Ivan, C. «Progress in organizing national and international comparisons for nuclear medicine measurements”. Rom. J. Phys.54, 7-8(2009)619-627

lucrari recente ale lmr in cadrul crp e2 10 05
Lucrari recente ale LMR in cadrulCRP - E2.10.05
  • Participarea la o comparareorganizata de AIEA pentru Co-57, 2008.
  • Recunoscuta ca o compararesuplimentara a CIPM-MRA, CCRI : CCRI(II)-S6.Co-57
  • Motive pentruorganizareacompararii:

- Tc-99m esteutilizatpescaralarga in clinici de diagnostic

  • Nu se puteaorganiza o comparareinternationala de Tc-99m datoritavietii sale scurte (6,007 ore)
  • Pregatireauneicompararirealenationale de Tc-99m
participarea la compararea de 57 co
Participarea la compararea de 57Co.

- Solutia a fost distribuita de QSA Global GmbH-Germania

- Etalonarea absoluta s-a facut prin metoda coinicidentelor 4πPC-γ.

- S-a reetalonat camera de ionizare CENTRONIC IG 12/20A, Etalon Secundar de Activitate al LMR.

Rezultatele au fost trimise la AIEA, fiind publicate in Rapoartele Internationale.

2 preliminary results of 57 co comparison
2. Preliminary results of 57Co comparison

RAPOARTE INTERNATIONALE :

1. B.E.Zimmerman,S.Palm.

Results of an international comparison of 57Co.

Appl. Radiat.Isot. 68(2010)1212 - 1220

Draft A Report of CCRI Comparison

CCRI(II)-S6.Co-57

B. E. Zimmerman1, S. Palm2, and G. Ratel3

1Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD USA

2 Dosimetry and Medical Radiation Physics Section, International Atomic Energy Agency, Vienna, Austria

3 Bureau International des Poids et Mesures, Sévres, France

radionuclidul tc 99m
Radionuclidul Tc-99m

- Solutiile au fost preparate prin elutia unor generatori comerciali, din solutie de Mo-99.

- Tc-99m este un radionuclid dificil de etalonat absolut

- Prima etalonare a camerei CENTRONIC s-a bazat pe metoda spectrometriei radiatiilor gama.

- In 2005 a fost elaborata o metoda originala de etalonare prin metoda coincidentelor; a fost reetalonata camera CENTRONIC. Cele doua valori au avut o concordanta foarte buna.

Sahagia, Maria.

Standardization of 99mTc.

Appl. Radiat. Isot. 64(2006)1234-1237

organizarea compararii de tc 99m
Organizarea compararii de Tc-99m
  • LMR aelaborat Procedura de Lucru,

Cod AC-PL-LMR-07, ”Organizarea de comparari interlaboratoare asupra masurarii activitatii surselor solide si a solutiilor radioactive”

  • Documente de referinta:

(i) ISO/IEC 17043,

(ii) ILAC-G13:2000 „Guidelines for Requirements for the Competence of Providers of Proficiency Testing Schemes”

(iii) EAL-P7, 1996 „Interlaboratory Comparisons of the European Cooperation for Accreditation of Laboratories”

desfasurarea compararii
Desfasurarea compararii
  • Conceptia a fost adaptata unui radionuclid de viata scurta
  • Participantii si-au eluat proprii generatori,

- au masurat fiola cu calibratoarele proprii,

- au completat formularul de comparare

- au trimis formularul completat si fiola la IFIN-HH

  • DRMR: compararile de I-131 si Tc-99m - parte a procesului de acreditare RENAR pentru CPRLAB
date raportate
Date raportate
  • Activitatea, AR , exprimata in MBq, sau mCi la momentul masurarii
  • Incertitudinea statistica combinata, uc2 % , k = 1
  • Alte date:

- Tipul echipamentului

- Situatia etalonarii/verificarii metrologice

  • Incercari suplimentare:

- masurarea fondului,

- masurari cu sursele test: Co-57, Ba-133, Co-60, Cs-137,

- corectii de dezintegrare

masurari la ifin hh lmr
Masurari la IFIN-HH, LMR
  • Fiolele au fost transportate la IFIN-HH
  • Activittatea a fost masurata cu camera CENTRONIC IG12/20A, Etalon Secundar de Activitate, calibrata cu solutie etalon.
  • Activitatea este ACA, Activitate Conventional Adevarata, sau Activitate de Referinta, incertitudinea statistica, uc1 %, k = 1.
slide14
Prelucrarea datelor la LMR:
  • Corectii de dezintegrare
  • Calculul parametrilor relevanti:
  • R = AR/ACA, raportul dintre valoarea raportata si cea conventional adevarata;
  • Diferenta;
  • Deviatia normalizata la incertitudinea statistica:, k = 2,
  • Rezultatele sunt declarate acceptabile, daca:
conclu ziile compararii
Concluziile compararii:

Din 7 valori raportate, 5 sunt in limita diferentei < 5 % , iar 7 sunt in limita< 10 %

-Toti participantii dse incedreaza in limita impusa Farmacopeea Europeana: incertitudine maxima de masurare in spitale de 10 %

Valoarea medie R = AR/ACA , pentru cele 7 valori raportate este:

R = 1.012 (Sn-1 = 4.9 %). Rezultatele sunt aproximativ normal distribuite

Criteriul En<1 , k=2,

- participantul L2b a subevaluat incertitudinea si este eliminat, desi diferenta sa este <5 %

concluzii
CONCLUZII
  • LMR, IFIN-HH a asigurat intregul suport laboratoarelor de medicina nucleara din Romania, prin:

1. Recunoasterea internationala a echivalentei etalonului romanesc de activitate prin comparari internationale: radionuclidul 57Co.

2. Obtinerea acreditarilor nationale necesare pentru asigurarea trasabilitatii nationale, organizarea unei comparari nationale de 99mTc si etalonarea calibratoarelor utilizate in unitatile de medicina nucleara.