1 / 7

Long Baseline Neutrino Experiment Target Irradiation Damage Studies at BLIP Experiment Status

Long Baseline Neutrino Experiment Target Irradiation Damage Studies at BLIP Experiment Status N. Simos Help from: L. Mausner, H. Kirk, H. Ludewig, N. Souchlas, N. Mokhov, P. Hurh, J. Misek, B. Zwaska, J. Hylen. What is LBNE and to Where ?. Neutrino SuperBeam from AGS. LBNE from Fermilab.

jkatrina
Download Presentation

Long Baseline Neutrino Experiment Target Irradiation Damage Studies at BLIP Experiment Status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Long Baseline Neutrino Experiment Target Irradiation Damage Studies at BLIP Experiment Status N. Simos Help from: L. Mausner, H. Kirk, H. Ludewig, N. Souchlas, N. Mokhov, P. Hurh, J. Misek, B. Zwaska, J. Hylen

  2. What is LBNE and to Where ? Neutrino SuperBeam from AGS LBNE from Fermilab

  3. Why LBNE target experiment and why BLIP? • A series of recent BNL studies at BLIP revealed surprising results regarding some materials of interest and their ability to withstand proton-induced irradiation (i.e. graphite, CC) – First signs of “trouble” observed with LHC collimator materials • A repeatable fluence threshold (~ 10^21 p/cm2) was identified using the BNL Linac at 200 MeV • Fermilab NuMI target (120 GeV) performance adhered to similar fluence limitations (~ factor of 4 higher) leading to questions such: why the difference? • Detailed studies (Fermilab/BNL) of interaction of matter with protons at different energies confirmed that the observed higher rate at BLIP is true!!

  4. Running at BLIP 0.42 dpa in 9 weeks (graphite) 400 W/g power density 9 weeks ~ 1 LBNE year at 700 kW

  5. Challenges in getting experiment off the ground • MUST work in tandem with Isotope Producing Operation • incident energy of ~112.6 MeV (102 MeV on first isotope target) • Gaussian beam similar to 117 MeV operation • Work with quantized Linac energy (139, 160.5, 181, 202) • While degrading the beam appropriately, design target configuration to operate within desired temperature bands so to mimic actual LBNE operations (avoid runaway temperatures especially in encapsulated targets) • Array of analyses and multitude of iterations proceeded the adoption of final configuration (MARS, MCNPX, SRIM, heat transfer and thermo-mechanical)

  6. So, following a 9-week irradiation phase at BLIP the real work will begin to identify: • Threshold for different graphite & CC so LBNE target lifetime can be assessed • Role of environment (vacuum, water cooled, or inert gas) in damage rate and lifetime • Targets currently in beam until the end of FY10 run • Post-irradiation study in hot labs of Bldg. 801 over the summer

More Related