1 / 17

ANGIOGRAFIJA KRVNIH SUDOVA VRATA NA VIŠESLOJNOM KT-SKENERU KOMPARACIJA 16- I 64-SLOJNOG kt

ANGIOGRAFIJA KRVNIH SUDOVA VRATA NA VIŠESLOJNOM KT-SKENERU KOMPARACIJA 16- I 64-SLOJNOG kt. AUTORI : BRANKA ČANIĆ VANJA MAREŠ. Anatomija. Arcus aortae. Tr. brachiocephalicus. Art. carotis communis sin. Art. subclavia sin. Art. subclavia dex. Art.carotis communis dex.

Download Presentation

ANGIOGRAFIJA KRVNIH SUDOVA VRATA NA VIŠESLOJNOM KT-SKENERU KOMPARACIJA 16- I 64-SLOJNOG kt

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ANGIOGRAFIJA KRVNIH SUDOVA VRATA NA VIŠESLOJNOM KT-SKENERUKOMPARACIJA 16- I 64-SLOJNOG kt AUTORI :BRANKA ČANIĆ VANJA MAREŠ

  2. Anatomija Arcus aortae Tr. brachiocephalicus Art. carotis communis sin. Art. subclavia sin. Art.subclavia dex. Art.carotis communis dex.

  3. Indikacije za pregled Indikacije za pregled: - kongenitalne anomalije - aneurizme - stenoze - AV malformati - vaskulitisi - trauma

  4. Potrebna aparatura 16-slojni KT skener Automatski injektor kontrasta 64-slojni KT skener Automatski injektor kontrasta

  5. Priprema pacijenta • Rozabraunilaplasirana u venu • Nalaziureeikreatinina u granicamareferentnihvrijednosti

  6. Koji se programi biraju na KT skeneru i automatskom injektoru?

  7. Planiranje pregleda 16-slojni KT (SIEMENS Somatom Sensation 16) 64-slojni KT (GE LightSpeed VCT)

  8. Programiranje injektora Za SIEMENS: Test bolus: 30 mlkontrasta, 20 mlNaCl Kontrastna serija: 70 mlkontrasta, 80 ml NaCl Brzinaprotoka je 4 ml/s, a pritisak je 325 psi Za GE: Kontrastna serija: 50 ml kontrasta, 50 ml NaCl Brzina protoka je 4 ml/s,a max pritisak je 300 psi Mallinckrodt OPTIVANTAGE DH NEMOTO DUAL SHOT Alpha

  9. Praćenje kontrasta SIEMENS: OpcijaTest Bolusza praćenje optimalne ispunjenosti kontrastom luka aorte GE: Opcija Smart Prep uz vizuelno praćenje kontrasta u arteriji basilaris

  10. 3D-rekonstrukcije na radnoj konzoli tehničara (SIEMENS)

  11. Najčešće greške prilikom pregleda i kako ih izbjeći Najčešći razlozi suboptimalnog pregleda: • usporen rad srca • “loše vene” kod pacijenta Kako doći do uspješnog pregleda? • Obratiti pažnju na uputnu dijagnozu,ultrazvučni pregled krvnihsudova vrata

  12. Rezultati iz naše prakse • Pregled se radi rutinski • Svakodnevni termini za angio program • Neurolozi i vaskularni hirurzi imaju pristup PACS-sistemu (slike i nalazi)

  13. Hvala na pažnji!