Frequently Asked Questions

Frequently Asked Questions. Technical and Installation. What will my slot depth/size for the bottom track need to be?.

jaeger
Download Presentation

Frequently Asked Questions

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Frequently Asked Questions Technical and Installation

  2. What will my slot depth/size for the bottom track need to be? The slot depth for standard flush tracks and full drainage tracks can be determined by measuring 2-5/16” down from the top of the finished floor to bottom of the slot. This allows for approximately 1/2” shim space below the track.

  3. What needs to happen with the drain hoses for the transverse drains and patented drainage track system? You will need to connect them with ½”ID drain tubing to your outside weep or drainage these tubes should be sloped a minimum of 1/8” per foot. Using a PVC pipe as a collection method for tubing may also be used.

  4. Does Weiland supply the attachment hardware? What supplies/tools will be needed? Due to varied installation techniques, Weiland does not provide actual installation hardware. Please see below for a partial list of tools and supplies to complete the installation.

  5. How wide and deep will my pocket need to be? Actual pocket depths are shown on drawings. The approximate pocket depth can be calculated by adding 5.5 inches to the panel width. The attached drawings can be found at www.weilandslidingdoors.com as PDF and dwg file.

  6. How wide and deep will my pocket need to be? (cont’d)

  7. How wide and deep will my pocket need to be? (cont’d)

  8. How do I calculate the weight of the systems and is the weight carried at the top or the bottom of the units? The weight of the system can be calculated by: Panel width x panel height ÷ 144 = Sqft. Sqft. x (____) x # of panels LS 7.5 LS weight point loaded on wheel sets at bottom track BBF 7.5 BBF/BF weight point loaded at center of panel on wheel carriage at head track BF 6.5 Assumptions: Glass is ¼” over ¼” I.G. units EXAMPLE: 57 x 97 ÷ 144 = 38.39 38.39 x 7.5 = 287.93 4 panels = 1, 152 system weight

  9. Why is the finished floor such a critical step? It is critical for the flooring and any grout lines to be at 3/16” below the top of the track for the panels to sit and seal properly. The exterior surface should be sloped properly so water won’t build up at the base of the panels. Allow a minimum of ¼” per foot slope from the edge of the door away from the opening.