RGA Lab at Carleton University

RGA Lab at Carleton University. Rahaf Ajaj, PhD. Target: Procuring 50 tones of low radioactivity Underground Aragon Urania Plant Extract 250 Kg/day of UAr from CO 2 well , with 99.9 % purity CO 2 removal, N 2 reduction Primary output: Ar , He, N 2

ivans
Download Presentation

RGA Lab at Carleton University

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RGA Lab at Carleton University Rahaf Ajaj, PhD

  2. Target: Procuring 50 tones of low radioactivity Underground Aragon • Urania Plant • Extract 250 Kg/day of UAr from CO2 well , with 99.9 % purity • CO2 removal, N2 reduction • Primary output: Ar, He, N2 • Minor contamination: O2, CO2, CH4, hydrocarbons • Gasses of interest: Ar, O2, He, H2, CO,CO2, CH4, N2 Introduction

  3. Proposed Plan

  4. Proposed Sampling Points

  5. Quadrupole Mass Spectrometry Platform • Model: Cirrus 3XD. • High Sensitivity Atmospheric Systems • Mass Range: 1 to 100, 100HP, 200 or 300 amu options • Detection limit: Gas and Mass Independent - the minimum detectable concentration 3 sigma baseline noise is < 15ppb (specified with Argon or Nitrogen). RGA System MKS

  6. System Sensitivity • Cirrus 3XD is reliable, • Multiple gas stream inlet (4-,8- or 16-way) • Detection limits for N2, O2, H2O (and all other peaks) is in the 1 ppm level • Gas matrix indicates overlapping peaks • Detection both detect both CO2/CO individually • Gasses Pressure • 640B pressure controller • Gasses Temperature • easy to warm up the system What are our concerns ?

  7. Multi-Stream Valve Control

  8. The RGA system has been calibrated by: • Pure Argon Cylinder (Purity of 99.999%) • CO2 Cylinder (purity of 99.995%) • CH4 Cylinder (purity of 99.999%) • 1% eachof H2, He, N2, O2, balance Ar • 500 ppm H2O, balance Ar • 1% CO, balance Ar System Calibration

  9. Pure Argon Cylinder (Purity of 99.999%)

  10. 1% CO, balance Ar

  11. Where: Control Room – Urania Site • When: Expected by Summer-2019 • Dimension : 24 x 12 x 19 Inch (length x width x height) • Weight: Benchtop: 78 pound. Installation MKS

  12. Thank You!