Sutron CFB Accubar Constant Flow Bubbler) Part Numbers 56-0133-25 Single Orifice 56-0134-25 Dual Orifice. Constant Flow Bubbler. -Self-Contained Bubble Gauge with built-in Logger -Log Capacity 300000 readings -SDI-12 Sensor -Easily Adjustable Bubble Rate -User Selectable Purge Scheduling

loader
I am the owner, or an agent authorized to act on behalf of the owner, of the copyrighted work described.
capcha
Download Presentation

PowerPoint Slideshow about 'Constant Flow Bubbler' - irving


An Image/Link below is provided (as is) to download presentation

Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author.While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server.


- - - - - - - - - - - - - - - - - - - - - - - - - - E N D - - - - - - - - - - - - - - - - - - - - - - - - - -
Presentation Transcript
slide1

Sutron CFBAccubar Constant Flow Bubbler) Part Numbers 56-0133-25 Single Orifice56-0134-25 Dual Orifice

constant flow bubbler
Constant Flow Bubbler

-Self-Contained Bubble Gauge with built-in Logger

-Log Capacity 300000 readings

-SDI-12 Sensor

-Easily Adjustable Bubble Rate

-User Selectable Purge Scheduling

-Auto-Purge on Blockage Detection

cfb specifications
CFB Specifications
  • Accuracy
    • 0-20ft +/- 0.01 ft. 20.0 - 57.5ft. 0.05% reading
  • Desiccant Life -Approximately 1 year depending on humidity at station and bubble rate and purge rate
  • Average Power- <8.3mA @ 12V for 3 sec measurement 15 min. interval, no purge
  • Quiescent Current <1mA
  • Pump On Current - 4Amp max, 2.5Amp typical
  • Pressure Range - 0 – 25 psi (0 -57.5ft or 17.5m of water)
more specs
More Specs

Outputs-SDI-12, RS232, RS485

Bubble Rate

-User Definable

Purge Pressure

-User Settable - 50psi Max (Default)

Enclosure -Nema 4 Fiberglass 12” x 15” x 7.5”

dual orifice bubbler
Dual Orifice Bubbler
  • 2 Holding Tanks
  • 2 Accubar Sensors / Can also use 1 Accubar
  • 2 Outputs
  • Desiccant Mounts on Outside of the Enclosure
  • 1 Pump
dual orifice bubbler1
Dual Orifice Bubbler
  • Dual Pressure Measurements
    • Measure Inflow and Outflow
  • Density Measurement
    • Measure Water Density
  • 2 Outputs - Orifice Tube Connections
  • Desiccant Mounts Outside of the Enclosure
setup
Setup

The CFB’s Default Setting Will Operate The System Properly For Most Users - Very Little Change To the Initial Setup Is Required. -Default Bubble Rate is 90 Bubbles per Min.

-Default Measurement Interval is 15 Minutes

-Default 10 Second Averaged Measurement -Default Measurement Units is Feet of Water

-Default Purge Pressure 50PSI

setup continued
Setup -Continued
  • 3 Ways to View and Modify the CFB’s Default Setting.
  • -Front Panel Key Pad and 2-Line Display
  • -SDI-12 Commands
  • -Command Line Interface Using Hyperterm or Procomm or Other Terminal Interface Software
setup continued1
Setup -Continued

There is a Visual Printout of the Menu Tree on the Inside of the Enclosure Door.

setup continued2
Setup -Continued

-Command Line Interface

-Make Serial Connection to CFB using Hyperterm

-Baud Rate 115200, No Parity, 8 Data Bits, 1 Stop Bit

Type “Help” at the command line prompt to see a list of commands including Measure, Log, Leak Test, Purge, Setup, Status…

For some commands type Help in front of the command to get more information. Such as Help Setup, or Help Log to view or download setup information or logged data.

setup continued3
Setup -Continued

-SDI-12 Commands

-View and modify the CFB’s default setting via SDI-12 commands, using your data logger’s SDI-12 Interface

-Setting the Stage Level with SDI-12 Command

0XS+10.00+1! – This command sets the water level reading to 10.00 feet of water

-Changing measurement units

0XUP+4+3! – This command sets the units of water level measurement to Meters of Water (4) with 3 Right Digits resolution

See CFB Manual For a Complete List of SDI-12 Commands.

purging the orifice tube
Purging the Orifice Tube
  • 2 Setup Options for Purging
    • Auto Purge – Schedule an Orifice Line Purge at Regular Scheduled Interval
    • AutoBlockage Detection
      • If Auto Blockage Detection is Enabled the CFB Will Save Battery Life and Desiccant Life By Purging Only When a Blockage of the Orifice Line is Detected.